Cargando…

Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy

The zebrafish is acknowledged as a reliable species of choices for biomechanical-related investigations. The definite quantification of the hydrodynamic flow physics caused by behavioral patterns, particularly in the zebrafish tail beat, is critical for a comprehensive understanding of food toxicity...

Descripción completa

Detalles Bibliográficos
Autores principales: Subendran, Satishkumar, Kang, Chun-Wei, Chen, Chia-Yuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827268/
https://www.ncbi.nlm.nih.gov/pubmed/33435330
http://dx.doi.org/10.3390/mi12010068
_version_ 1783640720987389952
author Subendran, Satishkumar
Kang, Chun-Wei
Chen, Chia-Yuan
author_facet Subendran, Satishkumar
Kang, Chun-Wei
Chen, Chia-Yuan
author_sort Subendran, Satishkumar
collection PubMed
description The zebrafish is acknowledged as a reliable species of choices for biomechanical-related investigations. The definite quantification of the hydrodynamic flow physics caused by behavioral patterns, particularly in the zebrafish tail beat, is critical for a comprehensive understanding of food toxicity in this species, and it can be further interpreted for possible human responses. The zebrafish’s body size and swimming speed place it in the intermediate flow regime, where both viscous and inertial forces play significant roles in the fluid–structure interaction. This pilot work highlighted the design and development of a novel microfluidic device coupled with a shape memory alloy (SMA) actuator to immobilize the zebrafish within the observation region for hydrodynamic quantification of the tail-beating behavioral responses, which may be induced by the overdose of food additive exposure. This study significantly examined behavioral patterns of the zebrafish in early developmental stages, which, in turn, generated vortex circulation. The presented findings on the behavioral responses of the zebrafish through the hydrodynamic analysis provided a golden protocol to assess the zebrafish as an animal model for new drug discovery and development.
format Online
Article
Text
id pubmed-7827268
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78272682021-01-25 Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy Subendran, Satishkumar Kang, Chun-Wei Chen, Chia-Yuan Micromachines (Basel) Article The zebrafish is acknowledged as a reliable species of choices for biomechanical-related investigations. The definite quantification of the hydrodynamic flow physics caused by behavioral patterns, particularly in the zebrafish tail beat, is critical for a comprehensive understanding of food toxicity in this species, and it can be further interpreted for possible human responses. The zebrafish’s body size and swimming speed place it in the intermediate flow regime, where both viscous and inertial forces play significant roles in the fluid–structure interaction. This pilot work highlighted the design and development of a novel microfluidic device coupled with a shape memory alloy (SMA) actuator to immobilize the zebrafish within the observation region for hydrodynamic quantification of the tail-beating behavioral responses, which may be induced by the overdose of food additive exposure. This study significantly examined behavioral patterns of the zebrafish in early developmental stages, which, in turn, generated vortex circulation. The presented findings on the behavioral responses of the zebrafish through the hydrodynamic analysis provided a golden protocol to assess the zebrafish as an animal model for new drug discovery and development. MDPI 2021-01-09 /pmc/articles/PMC7827268/ /pubmed/33435330 http://dx.doi.org/10.3390/mi12010068 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Subendran, Satishkumar
Kang, Chun-Wei
Chen, Chia-Yuan
Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy
title Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy
title_full Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy
title_fullStr Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy
title_full_unstemmed Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy
title_short Comprehensive Hydrodynamic Investigation of Zebrafish Tail Beats in a Microfluidic Device with a Shape Memory Alloy
title_sort comprehensive hydrodynamic investigation of zebrafish tail beats in a microfluidic device with a shape memory alloy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827268/
https://www.ncbi.nlm.nih.gov/pubmed/33435330
http://dx.doi.org/10.3390/mi12010068
work_keys_str_mv AT subendransatishkumar comprehensivehydrodynamicinvestigationofzebrafishtailbeatsinamicrofluidicdevicewithashapememoryalloy
AT kangchunwei comprehensivehydrodynamicinvestigationofzebrafishtailbeatsinamicrofluidicdevicewithashapememoryalloy
AT chenchiayuan comprehensivehydrodynamicinvestigationofzebrafishtailbeatsinamicrofluidicdevicewithashapememoryalloy