Cargando…
Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor
Lindane is documented by the Environmental Protection Agency (EPA) as one of the most toxic registered pesticides. Conventional detection of lindane in the environment requires manual field sampling and complex, time-consuming analytical sample handling relying on skilled labor. In this study, an el...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827346/ https://www.ncbi.nlm.nih.gov/pubmed/33429929 http://dx.doi.org/10.3390/s21020393 |
_version_ | 1783640740122853376 |
---|---|
author | Noori, Jafar Safaa Mortensen, John Geto, Alemnew |
author_facet | Noori, Jafar Safaa Mortensen, John Geto, Alemnew |
author_sort | Noori, Jafar Safaa |
collection | PubMed |
description | Lindane is documented by the Environmental Protection Agency (EPA) as one of the most toxic registered pesticides. Conventional detection of lindane in the environment requires manual field sampling and complex, time-consuming analytical sample handling relying on skilled labor. In this study, an electrochemical sensing system based on a modified electrode is reported. The system is capable of detecting lindane in aqueous medium in only 20 s. The surface of a conventional carbon electrode is modified with a film of conductive polymer that enables detection of lindane down to 30 nanomolar. The electrode modification procedure is simple and results in a robust sensor that can withstand intensive use. The sensitivity of the sensor is 7.18 µA/µM and the performance was demonstrated in the determination of lindane in spiked ground water. This suggests that the sensor is potentially capable of providing useful readings for decision makers. The rapid and sensitive quantification of lindane in aqueous medium is one step forward to new opportunities for direct, autonomous control of the pesticide level in the environment. |
format | Online Article Text |
id | pubmed-7827346 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-78273462021-01-25 Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor Noori, Jafar Safaa Mortensen, John Geto, Alemnew Sensors (Basel) Article Lindane is documented by the Environmental Protection Agency (EPA) as one of the most toxic registered pesticides. Conventional detection of lindane in the environment requires manual field sampling and complex, time-consuming analytical sample handling relying on skilled labor. In this study, an electrochemical sensing system based on a modified electrode is reported. The system is capable of detecting lindane in aqueous medium in only 20 s. The surface of a conventional carbon electrode is modified with a film of conductive polymer that enables detection of lindane down to 30 nanomolar. The electrode modification procedure is simple and results in a robust sensor that can withstand intensive use. The sensitivity of the sensor is 7.18 µA/µM and the performance was demonstrated in the determination of lindane in spiked ground water. This suggests that the sensor is potentially capable of providing useful readings for decision makers. The rapid and sensitive quantification of lindane in aqueous medium is one step forward to new opportunities for direct, autonomous control of the pesticide level in the environment. MDPI 2021-01-08 /pmc/articles/PMC7827346/ /pubmed/33429929 http://dx.doi.org/10.3390/s21020393 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Noori, Jafar Safaa Mortensen, John Geto, Alemnew Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor |
title | Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor |
title_full | Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor |
title_fullStr | Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor |
title_full_unstemmed | Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor |
title_short | Rapid and Sensitive Quantification of the Pesticide Lindane by Polymer Modified Electrochemical Sensor |
title_sort | rapid and sensitive quantification of the pesticide lindane by polymer modified electrochemical sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827346/ https://www.ncbi.nlm.nih.gov/pubmed/33429929 http://dx.doi.org/10.3390/s21020393 |
work_keys_str_mv | AT noorijafarsafaa rapidandsensitivequantificationofthepesticidelindanebypolymermodifiedelectrochemicalsensor AT mortensenjohn rapidandsensitivequantificationofthepesticidelindanebypolymermodifiedelectrochemicalsensor AT getoalemnew rapidandsensitivequantificationofthepesticidelindanebypolymermodifiedelectrochemicalsensor |