Cargando…
Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue
Shear wave elastography (SWE) has been demonstrated to be a useful tool in the differential diagnosis of ectopic thymus tissues (ETs), providing quantitative values of the shear wave stiffness (SWS) of both ETs and adjacent thyroid tissue. However, no data are available on the potential influence of...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827397/ https://www.ncbi.nlm.nih.gov/pubmed/33435276 http://dx.doi.org/10.3390/jcm10020214 |
_version_ | 1783640752454107136 |
---|---|
author | Adamczewski, Zbigniew Stasiak, Magdalena Stasiak, Bartłomiej Adamczewska, Magdalena Lewiński, Andrzej |
author_facet | Adamczewski, Zbigniew Stasiak, Magdalena Stasiak, Bartłomiej Adamczewska, Magdalena Lewiński, Andrzej |
author_sort | Adamczewski, Zbigniew |
collection | PubMed |
description | Shear wave elastography (SWE) has been demonstrated to be a useful tool in the differential diagnosis of ectopic thymus tissues (ETs), providing quantitative values of the shear wave stiffness (SWS) of both ETs and adjacent thyroid tissue. However, no data are available on the potential influence of the imaging plane (transverse vs. longitudinal) on the obtained SWS and shear wave ratio (SWR) values in SWE of these tissues. Moreover, no reports on the interobserver repeatability of SWE were published in regard to ETs. The aim of this study has been to evaluate the potential influence of the examination plane—transverse vs. longitudinal—on the SWS and SWR results, as well as to determine whether SWE of ETs is subjected to interobserver variability. SWE was demonstrated to have high inter- and intraobserver agreement in the evaluation of ETs and adjacent thyroid tissue. Significant differences between SWS values, but not SWR values, obtained in the transverse and longitudinal planes were observed. This phenomenon is probably a result of anisotropy-related artifacts and does not reduce the reliability of the method. SWE operators should be aware of the presence of plane-dependent artifacts to properly interpret the obtained results. |
format | Online Article Text |
id | pubmed-7827397 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-78273972021-01-25 Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue Adamczewski, Zbigniew Stasiak, Magdalena Stasiak, Bartłomiej Adamczewska, Magdalena Lewiński, Andrzej J Clin Med Article Shear wave elastography (SWE) has been demonstrated to be a useful tool in the differential diagnosis of ectopic thymus tissues (ETs), providing quantitative values of the shear wave stiffness (SWS) of both ETs and adjacent thyroid tissue. However, no data are available on the potential influence of the imaging plane (transverse vs. longitudinal) on the obtained SWS and shear wave ratio (SWR) values in SWE of these tissues. Moreover, no reports on the interobserver repeatability of SWE were published in regard to ETs. The aim of this study has been to evaluate the potential influence of the examination plane—transverse vs. longitudinal—on the SWS and SWR results, as well as to determine whether SWE of ETs is subjected to interobserver variability. SWE was demonstrated to have high inter- and intraobserver agreement in the evaluation of ETs and adjacent thyroid tissue. Significant differences between SWS values, but not SWR values, obtained in the transverse and longitudinal planes were observed. This phenomenon is probably a result of anisotropy-related artifacts and does not reduce the reliability of the method. SWE operators should be aware of the presence of plane-dependent artifacts to properly interpret the obtained results. MDPI 2021-01-09 /pmc/articles/PMC7827397/ /pubmed/33435276 http://dx.doi.org/10.3390/jcm10020214 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Adamczewski, Zbigniew Stasiak, Magdalena Stasiak, Bartłomiej Adamczewska, Magdalena Lewiński, Andrzej Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue |
title | Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue |
title_full | Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue |
title_fullStr | Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue |
title_full_unstemmed | Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue |
title_short | Interobserver Agreement and Plane-Dependent Intraobserver Variability of Shear Wave Sonoelastography in the Differential Diagnosis of Ectopic Thymus Tissue |
title_sort | interobserver agreement and plane-dependent intraobserver variability of shear wave sonoelastography in the differential diagnosis of ectopic thymus tissue |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827397/ https://www.ncbi.nlm.nih.gov/pubmed/33435276 http://dx.doi.org/10.3390/jcm10020214 |
work_keys_str_mv | AT adamczewskizbigniew interobserveragreementandplanedependentintraobservervariabilityofshearwavesonoelastographyinthedifferentialdiagnosisofectopicthymustissue AT stasiakmagdalena interobserveragreementandplanedependentintraobservervariabilityofshearwavesonoelastographyinthedifferentialdiagnosisofectopicthymustissue AT stasiakbartłomiej interobserveragreementandplanedependentintraobservervariabilityofshearwavesonoelastographyinthedifferentialdiagnosisofectopicthymustissue AT adamczewskamagdalena interobserveragreementandplanedependentintraobservervariabilityofshearwavesonoelastographyinthedifferentialdiagnosisofectopicthymustissue AT lewinskiandrzej interobserveragreementandplanedependentintraobservervariabilityofshearwavesonoelastographyinthedifferentialdiagnosisofectopicthymustissue |