Cargando…
Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications
The effect of hard segment content and diisocyanate structure on the transparency and mechanical properties of soft poly(dimethylsiloxane) (PDMS)-based urea elastomers (PSUs) was investigated. A series of PSU elastomers were synthesized from an aminopropyl-terminated PDMS ([Formula: see text]: 16,30...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827567/ https://www.ncbi.nlm.nih.gov/pubmed/33435271 http://dx.doi.org/10.3390/polym13020212 |
_version_ | 1783640793779535872 |
---|---|
author | Riehle, Natascha Athanasopulu, Kiriaki Kutuzova, Larysa Götz, Tobias Kandelbauer, Andreas Tovar, Günter E. M. Lorenz, Günter |
author_facet | Riehle, Natascha Athanasopulu, Kiriaki Kutuzova, Larysa Götz, Tobias Kandelbauer, Andreas Tovar, Günter E. M. Lorenz, Günter |
author_sort | Riehle, Natascha |
collection | PubMed |
description | The effect of hard segment content and diisocyanate structure on the transparency and mechanical properties of soft poly(dimethylsiloxane) (PDMS)-based urea elastomers (PSUs) was investigated. A series of PSU elastomers were synthesized from an aminopropyl-terminated PDMS ([Formula: see text]: 16,300 g·mol(−1)), which was prepared by ring chain equilibration of the monomers octamethylcyclotetrasiloxane (D(4)) and 1,3-bis(3-aminopropyl)-tetramethyldisiloxane (APTMDS). The hard segments (HSs) comprised diisocyanates of different symmetry, i.e., 4,4′-methylenebis(cyclohexyl isocyanate) (H(12)MDI), 4,4′-methylenebis(phenyl isocyanate) (MDI), isophorone diisocyanate (IPDI), and trans-1,4-cyclohexane diisocyanate (CHDI). The HS contents of the PSU elastomers based on H(12)MDI and IPDI were systematically varied between 5% and 20% by increasing the ratio of the diisocyanate and the chain extender APTMDS. PSU copolymers of very low urea HS contents (1.0–1.6%) were prepared without the chain extender. All PSU elastomers and copolymers exhibited good elastomeric properties and displayed elongation at break values between 600% and 1100%. The PSUs with HS contents below 10% were transparent and became increasingly translucent at HS contents of 15% and higher. The Young’s modulus (YM) and ultimate tensile strength values of the elastomers increased linearly with increasing HS content. The YM values differed significantly among the PSU copolymers depending on the symmetry of the diisocyanate. The softest elastomer was that based on the asymmetric IPDI. The elastomers synthesized from H(12)MDI and MDI both exhibited an intermediate YM, while the stiffest elastomer, i.e., that comprising the symmetric CHDI, had a YM three-times higher than that prepared with IPDI. The PSUs were subjected to load–unload cycles at 100% and 300% strain to study the influence of HS morphology on 10-cycle hysteresis behavior. At 100% strain, the first-cycle hysteresis values of the IPDI- and H(12)MDI-based elastomers first decreased to a minimum of approximately 9–10% at an HS content of 10% and increased again to 22–28% at an HS content of 20%. A similar, though less pronounced, trend was observed at 300% strain. First-cycle hysteresis among the PSU copolymers at 100% strain was lowest in the case of CHDI and highest in the IPDI-based elastomer. However, this effect was reversed at 300% strain, with CHDI displaying the highest hysteresis in the first cycle. In vitro cytotoxicity tests performed using HaCaT cells did not show any adverse effects, revealing their potential suitability for biomedical applications. |
format | Online Article Text |
id | pubmed-7827567 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-78275672021-01-25 Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications Riehle, Natascha Athanasopulu, Kiriaki Kutuzova, Larysa Götz, Tobias Kandelbauer, Andreas Tovar, Günter E. M. Lorenz, Günter Polymers (Basel) Article The effect of hard segment content and diisocyanate structure on the transparency and mechanical properties of soft poly(dimethylsiloxane) (PDMS)-based urea elastomers (PSUs) was investigated. A series of PSU elastomers were synthesized from an aminopropyl-terminated PDMS ([Formula: see text]: 16,300 g·mol(−1)), which was prepared by ring chain equilibration of the monomers octamethylcyclotetrasiloxane (D(4)) and 1,3-bis(3-aminopropyl)-tetramethyldisiloxane (APTMDS). The hard segments (HSs) comprised diisocyanates of different symmetry, i.e., 4,4′-methylenebis(cyclohexyl isocyanate) (H(12)MDI), 4,4′-methylenebis(phenyl isocyanate) (MDI), isophorone diisocyanate (IPDI), and trans-1,4-cyclohexane diisocyanate (CHDI). The HS contents of the PSU elastomers based on H(12)MDI and IPDI were systematically varied between 5% and 20% by increasing the ratio of the diisocyanate and the chain extender APTMDS. PSU copolymers of very low urea HS contents (1.0–1.6%) were prepared without the chain extender. All PSU elastomers and copolymers exhibited good elastomeric properties and displayed elongation at break values between 600% and 1100%. The PSUs with HS contents below 10% were transparent and became increasingly translucent at HS contents of 15% and higher. The Young’s modulus (YM) and ultimate tensile strength values of the elastomers increased linearly with increasing HS content. The YM values differed significantly among the PSU copolymers depending on the symmetry of the diisocyanate. The softest elastomer was that based on the asymmetric IPDI. The elastomers synthesized from H(12)MDI and MDI both exhibited an intermediate YM, while the stiffest elastomer, i.e., that comprising the symmetric CHDI, had a YM three-times higher than that prepared with IPDI. The PSUs were subjected to load–unload cycles at 100% and 300% strain to study the influence of HS morphology on 10-cycle hysteresis behavior. At 100% strain, the first-cycle hysteresis values of the IPDI- and H(12)MDI-based elastomers first decreased to a minimum of approximately 9–10% at an HS content of 10% and increased again to 22–28% at an HS content of 20%. A similar, though less pronounced, trend was observed at 300% strain. First-cycle hysteresis among the PSU copolymers at 100% strain was lowest in the case of CHDI and highest in the IPDI-based elastomer. However, this effect was reversed at 300% strain, with CHDI displaying the highest hysteresis in the first cycle. In vitro cytotoxicity tests performed using HaCaT cells did not show any adverse effects, revealing their potential suitability for biomedical applications. MDPI 2021-01-09 /pmc/articles/PMC7827567/ /pubmed/33435271 http://dx.doi.org/10.3390/polym13020212 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Riehle, Natascha Athanasopulu, Kiriaki Kutuzova, Larysa Götz, Tobias Kandelbauer, Andreas Tovar, Günter E. M. Lorenz, Günter Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications |
title | Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications |
title_full | Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications |
title_fullStr | Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications |
title_full_unstemmed | Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications |
title_short | Influence of Hard Segment Content and Diisocyanate Structure on the Transparency and Mechanical Properties of Poly(dimethylsiloxane)-Based Urea Elastomers for Biomedical Applications |
title_sort | influence of hard segment content and diisocyanate structure on the transparency and mechanical properties of poly(dimethylsiloxane)-based urea elastomers for biomedical applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827567/ https://www.ncbi.nlm.nih.gov/pubmed/33435271 http://dx.doi.org/10.3390/polym13020212 |
work_keys_str_mv | AT riehlenatascha influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications AT athanasopulukiriaki influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications AT kutuzovalarysa influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications AT gotztobias influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications AT kandelbauerandreas influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications AT tovargunterem influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications AT lorenzgunter influenceofhardsegmentcontentanddiisocyanatestructureonthetransparencyandmechanicalpropertiesofpolydimethylsiloxanebasedureaelastomersforbiomedicalapplications |