The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up
BACKGROUND: The newest generation of cementless titanium-coated, isoelastic monoblock cup with vitamin E-blended highly cross-linked polyethylene (HXLPE) was introduced to the market in 2009. The aim of the present study was to obtain mid-term follow-up data including migration and wear analyses. ME...
Autores principales: | Afghanyar, Yama, Joser, Sebastian, Tecle, Jonas, Drees, Philipp, Dargel, Jens, Rehbein, Philipp, Kutzner, Karl Philipp |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7827971/ https://www.ncbi.nlm.nih.gov/pubmed/33485345 http://dx.doi.org/10.1186/s12891-021-03981-8 |
Ejemplares similares
-
Primary stability of calcar-guided short-stem total hip arthroplasty in the treatment of osteonecrosis of the femoral head: migration analysis using EBRA-FCA
por: Afghanyar, Yama, et al.
Publicado: (2020) -
Can hip resurfacing be safely revised with short-stem total hip arthroplasty? A case series of six patients
por: Coutandin, Marcel, et al.
Publicado: (2021) -
One-stage bilateral versus unilateral short-stem total hip arthroplasty: A matched-pair analysis of 216 hips
por: Afghanyar, Yama, et al.
Publicado: (2021) -
Downsizing in total hip arthroplasty. A short stem as a revision implant
por: Coutandin, Marcel, et al.
Publicado: (2021) -
2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene
por: van Erp, Joost H J, et al.
Publicado: (2020)