Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study

Peripheral nerve interfaces (PNIs) allow us to extract motor, sensory, and autonomic information from the nervous system and use it as control signals in neuroprosthetic and neuromodulation applications. Recent efforts have aimed to improve the recording selectivity of PNIs, including by using spati...

Descripción completa

Detalles Bibliográficos
Autores principales: Sammut, Stephen, Koh, Ryan G. L., Zariffa, José
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7828277/
https://www.ncbi.nlm.nih.gov/pubmed/33445808
http://dx.doi.org/10.3390/s21020506
_version_ 1783640972426477568
author Sammut, Stephen
Koh, Ryan G. L.
Zariffa, José
author_facet Sammut, Stephen
Koh, Ryan G. L.
Zariffa, José
author_sort Sammut, Stephen
collection PubMed
description Peripheral nerve interfaces (PNIs) allow us to extract motor, sensory, and autonomic information from the nervous system and use it as control signals in neuroprosthetic and neuromodulation applications. Recent efforts have aimed to improve the recording selectivity of PNIs, including by using spatiotemporal patterns from multi-contact nerve cuff electrodes as input to a convolutional neural network (CNN). Before such a methodology can be translated to humans, its performance in chronic implantation scenarios must be evaluated. In this simulation study, approaches were evaluated for maintaining selective recording performance in the presence of two chronic implantation challenges: the growth of encapsulation tissue and rotation of the nerve cuff electrode. Performance over time was examined in three conditions: training the CNN at baseline only, supervised re-training with explicitly labeled data at periodic intervals, and a semi-supervised self-learning approach. This study demonstrated that a selective recording algorithm trained at baseline will likely fail over time due to changes in signal characteristics resulting from the chronic challenges. Results further showed that periodically recalibrating the selective recording algorithm could maintain its performance over time, and that a self-learning approach has the potential to reduce the frequency of recalibration.
format Online
Article
Text
id pubmed-7828277
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78282772021-01-25 Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study Sammut, Stephen Koh, Ryan G. L. Zariffa, José Sensors (Basel) Article Peripheral nerve interfaces (PNIs) allow us to extract motor, sensory, and autonomic information from the nervous system and use it as control signals in neuroprosthetic and neuromodulation applications. Recent efforts have aimed to improve the recording selectivity of PNIs, including by using spatiotemporal patterns from multi-contact nerve cuff electrodes as input to a convolutional neural network (CNN). Before such a methodology can be translated to humans, its performance in chronic implantation scenarios must be evaluated. In this simulation study, approaches were evaluated for maintaining selective recording performance in the presence of two chronic implantation challenges: the growth of encapsulation tissue and rotation of the nerve cuff electrode. Performance over time was examined in three conditions: training the CNN at baseline only, supervised re-training with explicitly labeled data at periodic intervals, and a semi-supervised self-learning approach. This study demonstrated that a selective recording algorithm trained at baseline will likely fail over time due to changes in signal characteristics resulting from the chronic challenges. Results further showed that periodically recalibrating the selective recording algorithm could maintain its performance over time, and that a self-learning approach has the potential to reduce the frequency of recalibration. MDPI 2021-01-12 /pmc/articles/PMC7828277/ /pubmed/33445808 http://dx.doi.org/10.3390/s21020506 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sammut, Stephen
Koh, Ryan G. L.
Zariffa, José
Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study
title Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study
title_full Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study
title_fullStr Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study
title_full_unstemmed Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study
title_short Compensation Strategies for Bioelectric Signal Changes in Chronic Selective Nerve Cuff Recordings: A Simulation Study
title_sort compensation strategies for bioelectric signal changes in chronic selective nerve cuff recordings: a simulation study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7828277/
https://www.ncbi.nlm.nih.gov/pubmed/33445808
http://dx.doi.org/10.3390/s21020506
work_keys_str_mv AT sammutstephen compensationstrategiesforbioelectricsignalchangesinchronicselectivenervecuffrecordingsasimulationstudy
AT kohryangl compensationstrategiesforbioelectricsignalchangesinchronicselectivenervecuffrecordingsasimulationstudy
AT zariffajose compensationstrategiesforbioelectricsignalchangesinchronicselectivenervecuffrecordingsasimulationstudy