Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR

In February 2020, our laboratory started to offer a RT-qPCR assay for the qualitative detection of severe acute respiratory syndrome coronavirus 2. A few months after the assay was released to our patients, some materials, reagents, and equipment became in short supply. Alternative protocols were ne...

Descripción completa

Detalles Bibliográficos
Autores principales: Barra, Gustavo Barcelos, Santa Rita, Ticiane Henriques, Mesquita, Pedro Góes, Jácomo, Rafael Henriques, Nery, Lídia Freire Abdalla
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7828326/
https://www.ncbi.nlm.nih.gov/pubmed/33450867
http://dx.doi.org/10.3390/genes12010090
_version_ 1783640984530190336
author Barra, Gustavo Barcelos
Santa Rita, Ticiane Henriques
Mesquita, Pedro Góes
Jácomo, Rafael Henriques
Nery, Lídia Freire Abdalla
author_facet Barra, Gustavo Barcelos
Santa Rita, Ticiane Henriques
Mesquita, Pedro Góes
Jácomo, Rafael Henriques
Nery, Lídia Freire Abdalla
author_sort Barra, Gustavo Barcelos
collection PubMed
description In February 2020, our laboratory started to offer a RT-qPCR assay for the qualitative detection of severe acute respiratory syndrome coronavirus 2. A few months after the assay was released to our patients, some materials, reagents, and equipment became in short supply. Alternative protocols were necessary in order to avoid stopping testing to the population. However, the suitability of these alternatives needs to be validated before their use. Here, we investigated if saliva is a reliable alternative specimen to nasopharyngeal swabs; if 0.45% saline is a reliable alternative to guanidine hydrochloride as a collection viral transport media; the stability of SARS-COV-2 in guanidine hydrochloride and in 0.45% saline for 10 and 50 days at room temperature; and if the primers/probe concentration and thermocycling times could be reduced so as to overcome the short supply of these reagents and equipment, without a significant loss of the assay performance. We found that saliva is not an appropriated specimen for our method—nasopharyngeal swabs perform better. Saline (0.45%) and guanidine hydrochloride have a similar SARS-CoV-2 diagnostic capability as tube additives. Reliable SARS-CoV-2 RNA detection can be performed after sample storage for 10 days at room temperature (18–23 °C) in both 0.45% saline and guanidine hydrochloride. Using synthetic RNA, and decreasing the concentration of primers by five-fold and probes by 2.5-fold, changed the assay limit of detection (LOD) from 7.2 copies/reaction to 23.7 copies/reaction and the subsequent reducing of thermocycling times changed the assay LOD from 23.7 copies/reaction to 44.2 copies/reaction. However, using real clinical samples with Cq values ranging from ~12.15 to ~36.46, the results of the three tested conditions were almost identical. These alterations will not affect the vast majority of diagnostics and increase the daily testing capability in 30% and increase primers and probe stocks in 500% and 250%, respectively. Taken together, the alternative protocols described here overcome the short supply of tubes, reagents and equipment during the SARS-CoV-2 pandemic, avoiding the collapse of test offering for the population: 105,757 samples were processed, and 25,156 SARS-CoV-2 diagnostics were performed from 9 May 2020 to 30 June 2020.
format Online
Article
Text
id pubmed-7828326
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78283262021-01-25 Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR Barra, Gustavo Barcelos Santa Rita, Ticiane Henriques Mesquita, Pedro Góes Jácomo, Rafael Henriques Nery, Lídia Freire Abdalla Genes (Basel) Article In February 2020, our laboratory started to offer a RT-qPCR assay for the qualitative detection of severe acute respiratory syndrome coronavirus 2. A few months after the assay was released to our patients, some materials, reagents, and equipment became in short supply. Alternative protocols were necessary in order to avoid stopping testing to the population. However, the suitability of these alternatives needs to be validated before their use. Here, we investigated if saliva is a reliable alternative specimen to nasopharyngeal swabs; if 0.45% saline is a reliable alternative to guanidine hydrochloride as a collection viral transport media; the stability of SARS-COV-2 in guanidine hydrochloride and in 0.45% saline for 10 and 50 days at room temperature; and if the primers/probe concentration and thermocycling times could be reduced so as to overcome the short supply of these reagents and equipment, without a significant loss of the assay performance. We found that saliva is not an appropriated specimen for our method—nasopharyngeal swabs perform better. Saline (0.45%) and guanidine hydrochloride have a similar SARS-CoV-2 diagnostic capability as tube additives. Reliable SARS-CoV-2 RNA detection can be performed after sample storage for 10 days at room temperature (18–23 °C) in both 0.45% saline and guanidine hydrochloride. Using synthetic RNA, and decreasing the concentration of primers by five-fold and probes by 2.5-fold, changed the assay limit of detection (LOD) from 7.2 copies/reaction to 23.7 copies/reaction and the subsequent reducing of thermocycling times changed the assay LOD from 23.7 copies/reaction to 44.2 copies/reaction. However, using real clinical samples with Cq values ranging from ~12.15 to ~36.46, the results of the three tested conditions were almost identical. These alterations will not affect the vast majority of diagnostics and increase the daily testing capability in 30% and increase primers and probe stocks in 500% and 250%, respectively. Taken together, the alternative protocols described here overcome the short supply of tubes, reagents and equipment during the SARS-CoV-2 pandemic, avoiding the collapse of test offering for the population: 105,757 samples were processed, and 25,156 SARS-CoV-2 diagnostics were performed from 9 May 2020 to 30 June 2020. MDPI 2021-01-13 /pmc/articles/PMC7828326/ /pubmed/33450867 http://dx.doi.org/10.3390/genes12010090 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Barra, Gustavo Barcelos
Santa Rita, Ticiane Henriques
Mesquita, Pedro Góes
Jácomo, Rafael Henriques
Nery, Lídia Freire Abdalla
Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR
title Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR
title_full Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR
title_fullStr Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR
title_full_unstemmed Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR
title_short Overcoming Supply Shortage for SARS-CoV-2 Detection by RT-qPCR
title_sort overcoming supply shortage for sars-cov-2 detection by rt-qpcr
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7828326/
https://www.ncbi.nlm.nih.gov/pubmed/33450867
http://dx.doi.org/10.3390/genes12010090
work_keys_str_mv AT barragustavobarcelos overcomingsupplyshortageforsarscov2detectionbyrtqpcr
AT santaritaticianehenriques overcomingsupplyshortageforsarscov2detectionbyrtqpcr
AT mesquitapedrogoes overcomingsupplyshortageforsarscov2detectionbyrtqpcr
AT jacomorafaelhenriques overcomingsupplyshortageforsarscov2detectionbyrtqpcr
AT nerylidiafreireabdalla overcomingsupplyshortageforsarscov2detectionbyrtqpcr