Cargando…

The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women

The aim of the study was to determine the between-trial and between-day reliability of the Glazer protocol and our multi-activity surface electromyography (sEMG) measurement protocol for pelvic floor muscle (PFM) evaluation. The bioelectrical activity of PFM was collected using an endovaginal electr...

Descripción completa

Detalles Bibliográficos
Autores principales: Oleksy, Łukasz, Mika, Anna, Sulowska-Daszyk, Iwona, Rosłoniec, Ewelina, Kielnar, Renata, Stolarczyk, Artur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830119/
https://www.ncbi.nlm.nih.gov/pubmed/33477461
http://dx.doi.org/10.3390/ijerph18020765
_version_ 1783641333840216064
author Oleksy, Łukasz
Mika, Anna
Sulowska-Daszyk, Iwona
Rosłoniec, Ewelina
Kielnar, Renata
Stolarczyk, Artur
author_facet Oleksy, Łukasz
Mika, Anna
Sulowska-Daszyk, Iwona
Rosłoniec, Ewelina
Kielnar, Renata
Stolarczyk, Artur
author_sort Oleksy, Łukasz
collection PubMed
description The aim of the study was to determine the between-trial and between-day reliability of the Glazer protocol and our multi-activity surface electromyography (sEMG) measurement protocol for pelvic floor muscle (PFM) evaluation. The bioelectrical activity of PFM was collected using an endovaginal electrode in 30 young, Caucasian, nulliparous women (age 22–27, 168.6 ± 5.1 cm, 57.1 ± 11.8 kg). The between-trial and between-day reliability of the original Glazer protocol and the new multi-activity sEMG protocol were assessed during the following phases: pre-baseline rest, phasic (flick) contractions, tonic contractions, endurance contraction, and post-baseline rest. The Glazer protocol was characterized by poor and moderate measurement reliability. The time-domain parameters for the rise and fall of the signal amplitude and median frequency showed poor between-trial and between-day reliability. The mean and peak amplitudes indicated mainly good between-trial and moderate between-days reliability. Our protocol showed moderate to excellent reliability of both time-domain and quantitative parameters of muscle recruitment. In our protocol, the frequency-domain parameters describing muscle fatigue demonstrated much higher reliability than in the case of the Glazer protocol. The most important information obtained in this study was the significant improvement of diagnostic validity in PFM bioelectrical activity evaluation. The higher reliability of our sEMG protocol compared to original Glazer protocol allowed us to suggest that protocol modifications and changes in sEMG signal processing methods were effective in the improvement of PFM assessment quality. The new parameters calculated from the sEMG signal proposed in our sEMG protocol allowed us to obtain additional clinically important information about PFM dysfunctions regarding specific deficits of muscle contraction such as decrease in muscle strength; endurance or coordination related to, e.g., stress urinary incontinence; or pelvic floor muscle imbalance after childbirth.
format Online
Article
Text
id pubmed-7830119
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78301192021-01-26 The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women Oleksy, Łukasz Mika, Anna Sulowska-Daszyk, Iwona Rosłoniec, Ewelina Kielnar, Renata Stolarczyk, Artur Int J Environ Res Public Health Article The aim of the study was to determine the between-trial and between-day reliability of the Glazer protocol and our multi-activity surface electromyography (sEMG) measurement protocol for pelvic floor muscle (PFM) evaluation. The bioelectrical activity of PFM was collected using an endovaginal electrode in 30 young, Caucasian, nulliparous women (age 22–27, 168.6 ± 5.1 cm, 57.1 ± 11.8 kg). The between-trial and between-day reliability of the original Glazer protocol and the new multi-activity sEMG protocol were assessed during the following phases: pre-baseline rest, phasic (flick) contractions, tonic contractions, endurance contraction, and post-baseline rest. The Glazer protocol was characterized by poor and moderate measurement reliability. The time-domain parameters for the rise and fall of the signal amplitude and median frequency showed poor between-trial and between-day reliability. The mean and peak amplitudes indicated mainly good between-trial and moderate between-days reliability. Our protocol showed moderate to excellent reliability of both time-domain and quantitative parameters of muscle recruitment. In our protocol, the frequency-domain parameters describing muscle fatigue demonstrated much higher reliability than in the case of the Glazer protocol. The most important information obtained in this study was the significant improvement of diagnostic validity in PFM bioelectrical activity evaluation. The higher reliability of our sEMG protocol compared to original Glazer protocol allowed us to suggest that protocol modifications and changes in sEMG signal processing methods were effective in the improvement of PFM assessment quality. The new parameters calculated from the sEMG signal proposed in our sEMG protocol allowed us to obtain additional clinically important information about PFM dysfunctions regarding specific deficits of muscle contraction such as decrease in muscle strength; endurance or coordination related to, e.g., stress urinary incontinence; or pelvic floor muscle imbalance after childbirth. MDPI 2021-01-18 2021-01 /pmc/articles/PMC7830119/ /pubmed/33477461 http://dx.doi.org/10.3390/ijerph18020765 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oleksy, Łukasz
Mika, Anna
Sulowska-Daszyk, Iwona
Rosłoniec, Ewelina
Kielnar, Renata
Stolarczyk, Artur
The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
title The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
title_full The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
title_fullStr The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
title_full_unstemmed The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
title_short The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
title_sort reliability of pelvic floor muscle bioelectrical activity (semg) assessment using a multi-activity measurement protocol in young women
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830119/
https://www.ncbi.nlm.nih.gov/pubmed/33477461
http://dx.doi.org/10.3390/ijerph18020765
work_keys_str_mv AT oleksyłukasz thereliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT mikaanna thereliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT sulowskadaszykiwona thereliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT rosłoniecewelina thereliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT kielnarrenata thereliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT stolarczykartur thereliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT oleksyłukasz reliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT mikaanna reliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT sulowskadaszykiwona reliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT rosłoniecewelina reliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT kielnarrenata reliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen
AT stolarczykartur reliabilityofpelvicfloormusclebioelectricalactivitysemgassessmentusingamultiactivitymeasurementprotocolinyoungwomen