Cargando…

Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study

Novel slim biopsy forceps provide some technical advantages to facilitate a more accurate diagnosis, although we are not aware of any comparative studies. Therefore, we compared tissue acquisition and diagnostic accuracy between novel slim biopsy forceps and conventional biopsy forceps in cases with...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Eun Suk, Park, Se Woo, Kim, Jung Hee, Jung, Jang Han, Yang, Min Jae, Park, Da Hae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830354/
https://www.ncbi.nlm.nih.gov/pubmed/33477372
http://dx.doi.org/10.3390/jpm11010055
_version_ 1783641393821908992
author Jung, Eun Suk
Park, Se Woo
Kim, Jung Hee
Jung, Jang Han
Yang, Min Jae
Park, Da Hae
author_facet Jung, Eun Suk
Park, Se Woo
Kim, Jung Hee
Jung, Jang Han
Yang, Min Jae
Park, Da Hae
author_sort Jung, Eun Suk
collection PubMed
description Novel slim biopsy forceps provide some technical advantages to facilitate a more accurate diagnosis, although we are not aware of any comparative studies. Therefore, we compared tissue acquisition and diagnostic accuracy between novel slim biopsy forceps and conventional biopsy forceps in cases with a biliary stricture. We reviewed 341 patients who underwent endoscopic retrograde cholangiopancreatography for the histological confirmation of biliary stricture at two tertiary hospitals between 2013 and 2020. The primary endpoint was the forceps’ diagnostic accuracies. We included 276 patients who underwent biopsy using the novel forceps (n = 130) or conventional forceps (n = 146). The novel forceps provided 81.7% sensitivity, 100.0% specificity, positive-predictive value (PPV) of 100.0%, and negative-predictive value (NPV) of 57.8%, with an accuracy of 85.4% when the diagnosis by endobiliary biopsy included suspected or positive malignancy. The conventional forceps provided 61.7% sensitivity, 100.0% specificity, PPV of 100.0%, and NPV of 36.1%, with an accuracy of 68.5%. Only novel forceps use was significantly associated with an accurate diagnosis (odds ratio: 2.70, 95% confidence interval: 1.52–5.00). There were no significant inter-group differences in the procedure-related rates of adverse events. Endobiliary biopsy using novel forceps offered better diagnostic performance and more acceptable procedure-related adverse events than conventional forceps.
format Online
Article
Text
id pubmed-7830354
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78303542021-01-26 Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study Jung, Eun Suk Park, Se Woo Kim, Jung Hee Jung, Jang Han Yang, Min Jae Park, Da Hae J Pers Med Article Novel slim biopsy forceps provide some technical advantages to facilitate a more accurate diagnosis, although we are not aware of any comparative studies. Therefore, we compared tissue acquisition and diagnostic accuracy between novel slim biopsy forceps and conventional biopsy forceps in cases with a biliary stricture. We reviewed 341 patients who underwent endoscopic retrograde cholangiopancreatography for the histological confirmation of biliary stricture at two tertiary hospitals between 2013 and 2020. The primary endpoint was the forceps’ diagnostic accuracies. We included 276 patients who underwent biopsy using the novel forceps (n = 130) or conventional forceps (n = 146). The novel forceps provided 81.7% sensitivity, 100.0% specificity, positive-predictive value (PPV) of 100.0%, and negative-predictive value (NPV) of 57.8%, with an accuracy of 85.4% when the diagnosis by endobiliary biopsy included suspected or positive malignancy. The conventional forceps provided 61.7% sensitivity, 100.0% specificity, PPV of 100.0%, and NPV of 36.1%, with an accuracy of 68.5%. Only novel forceps use was significantly associated with an accurate diagnosis (odds ratio: 2.70, 95% confidence interval: 1.52–5.00). There were no significant inter-group differences in the procedure-related rates of adverse events. Endobiliary biopsy using novel forceps offered better diagnostic performance and more acceptable procedure-related adverse events than conventional forceps. MDPI 2021-01-17 /pmc/articles/PMC7830354/ /pubmed/33477372 http://dx.doi.org/10.3390/jpm11010055 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jung, Eun Suk
Park, Se Woo
Kim, Jung Hee
Jung, Jang Han
Yang, Min Jae
Park, Da Hae
Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study
title Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study
title_full Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study
title_fullStr Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study
title_full_unstemmed Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study
title_short Comparison of the Diagnostic Performance of Novel Slim Biopsy Forceps with Conventional Biopsy Forceps for Biliary Stricture: A Multicenter Retrospective Study
title_sort comparison of the diagnostic performance of novel slim biopsy forceps with conventional biopsy forceps for biliary stricture: a multicenter retrospective study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830354/
https://www.ncbi.nlm.nih.gov/pubmed/33477372
http://dx.doi.org/10.3390/jpm11010055
work_keys_str_mv AT jungeunsuk comparisonofthediagnosticperformanceofnovelslimbiopsyforcepswithconventionalbiopsyforcepsforbiliarystrictureamulticenterretrospectivestudy
AT parksewoo comparisonofthediagnosticperformanceofnovelslimbiopsyforcepswithconventionalbiopsyforcepsforbiliarystrictureamulticenterretrospectivestudy
AT kimjunghee comparisonofthediagnosticperformanceofnovelslimbiopsyforcepswithconventionalbiopsyforcepsforbiliarystrictureamulticenterretrospectivestudy
AT jungjanghan comparisonofthediagnosticperformanceofnovelslimbiopsyforcepswithconventionalbiopsyforcepsforbiliarystrictureamulticenterretrospectivestudy
AT yangminjae comparisonofthediagnosticperformanceofnovelslimbiopsyforcepswithconventionalbiopsyforcepsforbiliarystrictureamulticenterretrospectivestudy
AT parkdahae comparisonofthediagnosticperformanceofnovelslimbiopsyforcepswithconventionalbiopsyforcepsforbiliarystrictureamulticenterretrospectivestudy