Cargando…

Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma

Glaucoma causes total or partial loss of vision in 10% of people over the age of 70, increasing their fragility and isolation. It is characterised by the destruction of the optic nerve fibres, which may result from excessively high intraocular pressure as well as other phenomena. Diagnosis is curren...

Descripción completa

Detalles Bibliográficos
Autores principales: Moreno, Marie-Valérie, Houriet, Cloé, Grounauer, Pierre-Alain
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830669/
https://www.ncbi.nlm.nih.gov/pubmed/33467457
http://dx.doi.org/10.3390/s21020579
_version_ 1783641472348717056
author Moreno, Marie-Valérie
Houriet, Cloé
Grounauer, Pierre-Alain
author_facet Moreno, Marie-Valérie
Houriet, Cloé
Grounauer, Pierre-Alain
author_sort Moreno, Marie-Valérie
collection PubMed
description Glaucoma causes total or partial loss of vision in 10% of people over the age of 70, increasing their fragility and isolation. It is characterised by the destruction of the optic nerve fibres, which may result from excessively high intraocular pressure as well as other phenomena. Diagnosis is currently reached through a combination of several checks, mainly of the eyes’ fundus, tonometry and gonioscopy. Prior to validation for human subjects, the objective of this study is to validate whether ocular phantom-based models could be used to diagnose glaucoma using an onboard system, which could, even at home, prevent the early-stage development of the pathology. Eight phantoms modelling healthy eyes and eight phantoms modelling eyes with glaucoma due to excessive intraocular pressure were measured using an onboard system, including lens and electrophysiology electronics. We measured the actual average Zr (real part of impedance) impedance of 160.9 ± 24.3 ohms (glaucoma ocular phantom models) versus 211.9 ± 36.9 ohms (healthy ocular phantom models), and an average total water volume (Vt) of 3.02 ± 0.35 mL (glaucoma ocular phantom models) versus 2.45 ± 0.28 mL (healthy ocular Phantoms). On average, we obtained 51 ohms (−24.1%) less and 0.57 mL (22.9%) of total water volume more, respectively. Normality tests (Shapiro–Wilk) for Vt and Zr indicate p < 0.001 and p < 0.01, respectively. Since these variables do not respect normal laws, unmatched Mann–Whitney tests were performed indicating a significant difference between Vt and Zr in the healthy ocular phantom models and those modelling glaucoma. To conclude, this preliminary study indicates the possibility of discriminating between healthy eyes with those with glaucoma. However, further large-scale studies involving healthy eyes and those suffering from glaucoma are necessary to generate viable models.
format Online
Article
Text
id pubmed-7830669
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78306692021-01-26 Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma Moreno, Marie-Valérie Houriet, Cloé Grounauer, Pierre-Alain Sensors (Basel) Article Glaucoma causes total or partial loss of vision in 10% of people over the age of 70, increasing their fragility and isolation. It is characterised by the destruction of the optic nerve fibres, which may result from excessively high intraocular pressure as well as other phenomena. Diagnosis is currently reached through a combination of several checks, mainly of the eyes’ fundus, tonometry and gonioscopy. Prior to validation for human subjects, the objective of this study is to validate whether ocular phantom-based models could be used to diagnose glaucoma using an onboard system, which could, even at home, prevent the early-stage development of the pathology. Eight phantoms modelling healthy eyes and eight phantoms modelling eyes with glaucoma due to excessive intraocular pressure were measured using an onboard system, including lens and electrophysiology electronics. We measured the actual average Zr (real part of impedance) impedance of 160.9 ± 24.3 ohms (glaucoma ocular phantom models) versus 211.9 ± 36.9 ohms (healthy ocular phantom models), and an average total water volume (Vt) of 3.02 ± 0.35 mL (glaucoma ocular phantom models) versus 2.45 ± 0.28 mL (healthy ocular Phantoms). On average, we obtained 51 ohms (−24.1%) less and 0.57 mL (22.9%) of total water volume more, respectively. Normality tests (Shapiro–Wilk) for Vt and Zr indicate p < 0.001 and p < 0.01, respectively. Since these variables do not respect normal laws, unmatched Mann–Whitney tests were performed indicating a significant difference between Vt and Zr in the healthy ocular phantom models and those modelling glaucoma. To conclude, this preliminary study indicates the possibility of discriminating between healthy eyes with those with glaucoma. However, further large-scale studies involving healthy eyes and those suffering from glaucoma are necessary to generate viable models. MDPI 2021-01-15 /pmc/articles/PMC7830669/ /pubmed/33467457 http://dx.doi.org/10.3390/s21020579 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moreno, Marie-Valérie
Houriet, Cloé
Grounauer, Pierre-Alain
Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
title Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
title_full Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
title_fullStr Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
title_full_unstemmed Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
title_short Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
title_sort ocular phantom-based feasibility study of an early diagnosis device for glaucoma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830669/
https://www.ncbi.nlm.nih.gov/pubmed/33467457
http://dx.doi.org/10.3390/s21020579
work_keys_str_mv AT morenomarievalerie ocularphantombasedfeasibilitystudyofanearlydiagnosisdeviceforglaucoma
AT hourietcloe ocularphantombasedfeasibilitystudyofanearlydiagnosisdeviceforglaucoma
AT grounauerpierrealain ocularphantombasedfeasibilitystudyofanearlydiagnosisdeviceforglaucoma