Cargando…

Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation

Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet be...

Descripción completa

Detalles Bibliográficos
Autores principales: Gehrke, Peter, Hartjen, Philip, Smeets, Ralf, Gosau, Martin, Peters, Ulrike, Beikler, Thomas, Fischer, Carsten, Stolzer, Carolin, Geis-Gerstorfer, Jürgen, Weigl, Paul, Schäfer, Sogand
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830972/
https://www.ncbi.nlm.nih.gov/pubmed/33477311
http://dx.doi.org/10.3390/ijms22020881
_version_ 1783641534392958976
author Gehrke, Peter
Hartjen, Philip
Smeets, Ralf
Gosau, Martin
Peters, Ulrike
Beikler, Thomas
Fischer, Carsten
Stolzer, Carolin
Geis-Gerstorfer, Jürgen
Weigl, Paul
Schäfer, Sogand
author_facet Gehrke, Peter
Hartjen, Philip
Smeets, Ralf
Gosau, Martin
Peters, Ulrike
Beikler, Thomas
Fischer, Carsten
Stolzer, Carolin
Geis-Gerstorfer, Jürgen
Weigl, Paul
Schäfer, Sogand
author_sort Gehrke, Peter
collection PubMed
description Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10(−4) µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.
format Online
Article
Text
id pubmed-7830972
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78309722021-01-26 Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation Gehrke, Peter Hartjen, Philip Smeets, Ralf Gosau, Martin Peters, Ulrike Beikler, Thomas Fischer, Carsten Stolzer, Carolin Geis-Gerstorfer, Jürgen Weigl, Paul Schäfer, Sogand Int J Mol Sci Article Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10(−4) µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions. MDPI 2021-01-17 /pmc/articles/PMC7830972/ /pubmed/33477311 http://dx.doi.org/10.3390/ijms22020881 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gehrke, Peter
Hartjen, Philip
Smeets, Ralf
Gosau, Martin
Peters, Ulrike
Beikler, Thomas
Fischer, Carsten
Stolzer, Carolin
Geis-Gerstorfer, Jürgen
Weigl, Paul
Schäfer, Sogand
Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
title Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
title_full Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
title_fullStr Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
title_full_unstemmed Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
title_short Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
title_sort marginal adaptation and microbial leakage at conometric prosthetic connections for implant-supported single crowns: an in vitro investigation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830972/
https://www.ncbi.nlm.nih.gov/pubmed/33477311
http://dx.doi.org/10.3390/ijms22020881
work_keys_str_mv AT gehrkepeter marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT hartjenphilip marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT smeetsralf marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT gosaumartin marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT petersulrike marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT beiklerthomas marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT fischercarsten marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT stolzercarolin marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT geisgerstorferjurgen marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT weiglpaul marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation
AT schafersogand marginaladaptationandmicrobialleakageatconometricprostheticconnectionsforimplantsupportedsinglecrownsaninvitroinvestigation