Cargando…

Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment

Batik wastewater, in general, is colored and has high concentrations of BOD (biological oxygen demand), COD (chemical oxygen demand), and dissolved and suspended solids. Polysulfone (PSf)-based membranes with the addition of polyvinyl pyrrolidone (PVP) were prepared to treat batik industrial wastewa...

Descripción completa

Detalles Bibliográficos
Autores principales: Febriasari, Arifina, Huriya, Ananto, Annisa Hasna, Suhartini, Meri, Kartohardjono, Sutrasno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7831512/
https://www.ncbi.nlm.nih.gov/pubmed/33477646
http://dx.doi.org/10.3390/membranes11010066
_version_ 1783641639375339520
author Febriasari, Arifina
Huriya,
Ananto, Annisa Hasna
Suhartini, Meri
Kartohardjono, Sutrasno
author_facet Febriasari, Arifina
Huriya,
Ananto, Annisa Hasna
Suhartini, Meri
Kartohardjono, Sutrasno
author_sort Febriasari, Arifina
collection PubMed
description Batik wastewater, in general, is colored and has high concentrations of BOD (biological oxygen demand), COD (chemical oxygen demand), and dissolved and suspended solids. Polysulfone (PSf)-based membranes with the addition of polyvinyl pyrrolidone (PVP) were prepared to treat batik industrial wastewater. PSf/PVP membranes were prepared using the phase inversion method with N-methyl-2 pyrrolidone (NMP) as the solvent. Based on the membrane characterization through FESEM, water contact angle, porosity, and mechanical tests showed a phenomenon where the addition of PVP provided thermodynamic and kinetic effects on membrane formation, thereby affecting porosity, thickness, and hydrophilicity of the membranes. The study aims to observe the effect of adding PVP on polysulfone membrane permeability and antifouling performance on a laboratory scale through the ultrafiltration (UF) process. With the addition of PVP, the operational pressure of the polysulfone membrane was reduced compared to that without PVP. Based on the membrane filtration results, the highest removal efficiencies of COD, TDS (total dissolved solid), and conductivity achieved in the study were 80.4, 84.6, and 83.6%, respectively, on the PSf/PVP 0.35 membrane operated at 4 bar. Moreover, the highest color removal efficiency was 85.73% on the PSf/PVP 0.25 operated at 5 bar. The antifouling performance was identified by calculating the value of total, reversible, and irreversible membrane fouling, wherein in this study, the membrane with the best antifouling performance was PSf/PVP 0.25.
format Online
Article
Text
id pubmed-7831512
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78315122021-01-26 Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment Febriasari, Arifina Huriya, Ananto, Annisa Hasna Suhartini, Meri Kartohardjono, Sutrasno Membranes (Basel) Article Batik wastewater, in general, is colored and has high concentrations of BOD (biological oxygen demand), COD (chemical oxygen demand), and dissolved and suspended solids. Polysulfone (PSf)-based membranes with the addition of polyvinyl pyrrolidone (PVP) were prepared to treat batik industrial wastewater. PSf/PVP membranes were prepared using the phase inversion method with N-methyl-2 pyrrolidone (NMP) as the solvent. Based on the membrane characterization through FESEM, water contact angle, porosity, and mechanical tests showed a phenomenon where the addition of PVP provided thermodynamic and kinetic effects on membrane formation, thereby affecting porosity, thickness, and hydrophilicity of the membranes. The study aims to observe the effect of adding PVP on polysulfone membrane permeability and antifouling performance on a laboratory scale through the ultrafiltration (UF) process. With the addition of PVP, the operational pressure of the polysulfone membrane was reduced compared to that without PVP. Based on the membrane filtration results, the highest removal efficiencies of COD, TDS (total dissolved solid), and conductivity achieved in the study were 80.4, 84.6, and 83.6%, respectively, on the PSf/PVP 0.35 membrane operated at 4 bar. Moreover, the highest color removal efficiency was 85.73% on the PSf/PVP 0.25 operated at 5 bar. The antifouling performance was identified by calculating the value of total, reversible, and irreversible membrane fouling, wherein in this study, the membrane with the best antifouling performance was PSf/PVP 0.25. MDPI 2021-01-18 /pmc/articles/PMC7831512/ /pubmed/33477646 http://dx.doi.org/10.3390/membranes11010066 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Febriasari, Arifina
Huriya,
Ananto, Annisa Hasna
Suhartini, Meri
Kartohardjono, Sutrasno
Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment
title Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment
title_full Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment
title_fullStr Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment
title_full_unstemmed Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment
title_short Polysulfone–Polyvinyl Pyrrolidone Blend Polymer Composite Membranes for Batik Industrial Wastewater Treatment
title_sort polysulfone–polyvinyl pyrrolidone blend polymer composite membranes for batik industrial wastewater treatment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7831512/
https://www.ncbi.nlm.nih.gov/pubmed/33477646
http://dx.doi.org/10.3390/membranes11010066
work_keys_str_mv AT febriasariarifina polysulfonepolyvinylpyrrolidoneblendpolymercompositemembranesforbatikindustrialwastewatertreatment
AT huriya polysulfonepolyvinylpyrrolidoneblendpolymercompositemembranesforbatikindustrialwastewatertreatment
AT anantoannisahasna polysulfonepolyvinylpyrrolidoneblendpolymercompositemembranesforbatikindustrialwastewatertreatment
AT suhartinimeri polysulfonepolyvinylpyrrolidoneblendpolymercompositemembranesforbatikindustrialwastewatertreatment
AT kartohardjonosutrasno polysulfonepolyvinylpyrrolidoneblendpolymercompositemembranesforbatikindustrialwastewatertreatment