Cargando…

Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge

Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an u...

Descripción completa

Detalles Bibliográficos
Autores principales: Frett, Timo, Petrat, Guido, Arz, Michael, Leguy, Carole
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7831654/
https://www.ncbi.nlm.nih.gov/pubmed/33519098
http://dx.doi.org/10.1007/s12217-020-09850-8
_version_ 1783641664203522048
author Frett, Timo
Petrat, Guido
Arz, Michael
Leguy, Carole
author_facet Frett, Timo
Petrat, Guido
Arz, Michael
Leguy, Carole
author_sort Frett, Timo
collection PubMed
description Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an ultrasound probe has been installed on a Short Arm Human Centrifuge. A feasibility study was conducted to define the use capabilities and limitations of such a novel method. The objective of this study is to estimate the reproducibility and precision of remotely controlled vascular ultrasound assessment under centrifugation by assessing peripheral vascular diameter and wall distension. Four repeated centrifugation runs of 5 min, with 2.4 g at feet level, were performed including a 15 min rest between each run for a group of eight healthy male volunteers. Vascular diameter and distention were assessed for the common carotid artery (CCA) and the femoral artery (FA) by ultrasound imaging using a 10 MHz linear array probe (Mylab1, Esaote). Ultrasound measurements were consecutively performed: a) by an expert user in hand-held mode in standing as well as supine position, b) using the telerobotic arm without centrifugation as baseline and c) using the telerobotic arm during centrifugation. Vascular responses were compared between baseline and under centrifugation. Inter-, intra-registration and group variability have been assessed for hand-held and remotely controlled examination. The results show that intra-registration variability, σ(h) , was always smaller than inter-registration variability, σ(m), that is in turned smaller than the inter-subject variability σ(g) (σ(h) < σ(m) < σ(g)). Centrifugation caused no significant changes in CCA diameter but a lower carotid distension compared to manual and robotic ultrasound in supine position (p < 0.05). Femoral diameter was significantly decreased in hypergravity compared to robotic sonography without centrifugation. A good reproducibility and precision of the remotely controlled vascular ultrasound assessment under centrifugation could be demonstrated. In conclusion, arterial wall dynamics can be precisely assessed for the CCA and femoral artery during centrifugation using a telerobotic ultrasound measurement system. Potential improvements to further enhance reproducibility and safety of the system are discussed.
format Online
Article
Text
id pubmed-7831654
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-78316542021-01-29 Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge Frett, Timo Petrat, Guido Arz, Michael Leguy, Carole Microgravity Sci Technol Original Article Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an ultrasound probe has been installed on a Short Arm Human Centrifuge. A feasibility study was conducted to define the use capabilities and limitations of such a novel method. The objective of this study is to estimate the reproducibility and precision of remotely controlled vascular ultrasound assessment under centrifugation by assessing peripheral vascular diameter and wall distension. Four repeated centrifugation runs of 5 min, with 2.4 g at feet level, were performed including a 15 min rest between each run for a group of eight healthy male volunteers. Vascular diameter and distention were assessed for the common carotid artery (CCA) and the femoral artery (FA) by ultrasound imaging using a 10 MHz linear array probe (Mylab1, Esaote). Ultrasound measurements were consecutively performed: a) by an expert user in hand-held mode in standing as well as supine position, b) using the telerobotic arm without centrifugation as baseline and c) using the telerobotic arm during centrifugation. Vascular responses were compared between baseline and under centrifugation. Inter-, intra-registration and group variability have been assessed for hand-held and remotely controlled examination. The results show that intra-registration variability, σ(h) , was always smaller than inter-registration variability, σ(m), that is in turned smaller than the inter-subject variability σ(g) (σ(h) < σ(m) < σ(g)). Centrifugation caused no significant changes in CCA diameter but a lower carotid distension compared to manual and robotic ultrasound in supine position (p < 0.05). Femoral diameter was significantly decreased in hypergravity compared to robotic sonography without centrifugation. A good reproducibility and precision of the remotely controlled vascular ultrasound assessment under centrifugation could be demonstrated. In conclusion, arterial wall dynamics can be precisely assessed for the CCA and femoral artery during centrifugation using a telerobotic ultrasound measurement system. Potential improvements to further enhance reproducibility and safety of the system are discussed. Springer Netherlands 2021-01-23 2021 /pmc/articles/PMC7831654/ /pubmed/33519098 http://dx.doi.org/10.1007/s12217-020-09850-8 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Frett, Timo
Petrat, Guido
Arz, Michael
Leguy, Carole
Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
title Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
title_full Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
title_fullStr Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
title_full_unstemmed Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
title_short Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
title_sort quantitative evaluation of a telerobotic system for vascular ultrasound measurement on a short arm human centrifuge
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7831654/
https://www.ncbi.nlm.nih.gov/pubmed/33519098
http://dx.doi.org/10.1007/s12217-020-09850-8
work_keys_str_mv AT fretttimo quantitativeevaluationofateleroboticsystemforvascularultrasoundmeasurementonashortarmhumancentrifuge
AT petratguido quantitativeevaluationofateleroboticsystemforvascularultrasoundmeasurementonashortarmhumancentrifuge
AT arzmichael quantitativeevaluationofateleroboticsystemforvascularultrasoundmeasurementonashortarmhumancentrifuge
AT leguycarole quantitativeevaluationofateleroboticsystemforvascularultrasoundmeasurementonashortarmhumancentrifuge