The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers

INTRODUCTION: Early hemorrhage is often missed by traditional vital signs because of physiological reserve, especially in the young and healthy. We have developed a novel, wearable, wireless Doppler ultrasound patch that tracks real-time blood velocity in the common carotid artery. MATERIALS AND MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Kenny, Jon-Émile S, Eibl, Andrew M, Parrotta, Matthew, Long, Bradley F, Eibl, Joseph K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7832258/
https://www.ncbi.nlm.nih.gov/pubmed/33499507
http://dx.doi.org/10.1093/milmed/usaa248
_version_ 1783641797146181632
author Kenny, Jon-Émile S
Eibl, Andrew M
Parrotta, Matthew
Long, Bradley F
Eibl, Joseph K
author_facet Kenny, Jon-Émile S
Eibl, Andrew M
Parrotta, Matthew
Long, Bradley F
Eibl, Joseph K
author_sort Kenny, Jon-Émile S
collection PubMed
description INTRODUCTION: Early hemorrhage is often missed by traditional vital signs because of physiological reserve, especially in the young and healthy. We have developed a novel, wearable, wireless Doppler ultrasound patch that tracks real-time blood velocity in the common carotid artery. MATERIALS AND METHODS: We studied eight healthy volunteers who decreased their cardiac output using a standardized Valsalva maneuver. In all eight, we simultaneously monitored the velocity time integral (VTI) of the common carotid artery (using the ultrasound patch) as well as the descending aorta (using a traditional pulsed wave duplex imaging system); the descending aortic VTI was used as a surrogate for left ventricular stroke volume (SV). Additionally, in a subset of four, we simultaneously measured SV using a noninvasive pulse contour analysis device. RESULTS: From baseline to peak effect of Valsalva, there was a statistically significant fall in descending aortic and common carotid VTI of 37% (P = 0.0005) and 23% (P < 0.0001), respectively. Both values returned to baseline on recovery. Additionally, a novel index from the carotid ultrasound patch (i.e., the heart rate divided by the carotid artery VTI) detected a 10% fall in aortic VTI with high sensitivity and specificity (100% and 100%, respectively); this novel index also accurately detected a 10% decrease in SV as measured by the noninvasive SV monitor. The mean arterial pressure, measured by the noninvasive pulse contour device, did not correctly detect the fall in SV. CONCLUSION: In summary, a novel index from a wireless Doppler ultrasound patch may be more sensitive and specific for detecting decreased cardiac output than standard vital signs in healthy volunteers.
format Online
Article
Text
id pubmed-7832258
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-78322582021-01-28 The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers Kenny, Jon-Émile S Eibl, Andrew M Parrotta, Matthew Long, Bradley F Eibl, Joseph K Mil Med Supplement Article INTRODUCTION: Early hemorrhage is often missed by traditional vital signs because of physiological reserve, especially in the young and healthy. We have developed a novel, wearable, wireless Doppler ultrasound patch that tracks real-time blood velocity in the common carotid artery. MATERIALS AND METHODS: We studied eight healthy volunteers who decreased their cardiac output using a standardized Valsalva maneuver. In all eight, we simultaneously monitored the velocity time integral (VTI) of the common carotid artery (using the ultrasound patch) as well as the descending aorta (using a traditional pulsed wave duplex imaging system); the descending aortic VTI was used as a surrogate for left ventricular stroke volume (SV). Additionally, in a subset of four, we simultaneously measured SV using a noninvasive pulse contour analysis device. RESULTS: From baseline to peak effect of Valsalva, there was a statistically significant fall in descending aortic and common carotid VTI of 37% (P = 0.0005) and 23% (P < 0.0001), respectively. Both values returned to baseline on recovery. Additionally, a novel index from the carotid ultrasound patch (i.e., the heart rate divided by the carotid artery VTI) detected a 10% fall in aortic VTI with high sensitivity and specificity (100% and 100%, respectively); this novel index also accurately detected a 10% decrease in SV as measured by the noninvasive SV monitor. The mean arterial pressure, measured by the noninvasive pulse contour device, did not correctly detect the fall in SV. CONCLUSION: In summary, a novel index from a wireless Doppler ultrasound patch may be more sensitive and specific for detecting decreased cardiac output than standard vital signs in healthy volunteers. Oxford University Press 2021-01-25 /pmc/articles/PMC7832258/ /pubmed/33499507 http://dx.doi.org/10.1093/milmed/usaa248 Text en © The Association of Military Surgeons of the United States 2021. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Supplement Article
Kenny, Jon-Émile S
Eibl, Andrew M
Parrotta, Matthew
Long, Bradley F
Eibl, Joseph K
The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
title The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
title_full The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
title_fullStr The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
title_full_unstemmed The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
title_short The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
title_sort feasibility of a novel index from a wireless doppler ultrasound patch to detect decreasing cardiac output in healthy volunteers
topic Supplement Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7832258/
https://www.ncbi.nlm.nih.gov/pubmed/33499507
http://dx.doi.org/10.1093/milmed/usaa248
work_keys_str_mv AT kennyjonemiles thefeasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT eiblandrewm thefeasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT parrottamatthew thefeasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT longbradleyf thefeasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT eibljosephk thefeasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT kennyjonemiles feasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT eiblandrewm feasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT parrottamatthew feasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT longbradleyf feasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers
AT eibljosephk feasibilityofanovelindexfromawirelessdopplerultrasoundpatchtodetectdecreasingcardiacoutputinhealthyvolunteers