Cargando…

Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2

The coronavirus disease 2019 (COVID-19) epidemic continues to ravage the world. In epidemic control, dealing with a large number of samples is a huge challenge. In this study, a point-of-care test (POCT) system was successfully developed and applied for rapid and accurate detection of immunoglobulin...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Tao, Sui, Zhiwei, Huang, Zhenghui, Xie, Jie, Wen, Kai, Zhang, Yongzhuo, Huang, Wenfeng, Mi, Wei, Peng, Ke, Dai, Xinhua, Fang, Xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7833039/
https://www.ncbi.nlm.nih.gov/pubmed/33519091
http://dx.doi.org/10.1016/j.snb.2020.129415
_version_ 1783641974183559168
author Peng, Tao
Sui, Zhiwei
Huang, Zhenghui
Xie, Jie
Wen, Kai
Zhang, Yongzhuo
Huang, Wenfeng
Mi, Wei
Peng, Ke
Dai, Xinhua
Fang, Xiang
author_facet Peng, Tao
Sui, Zhiwei
Huang, Zhenghui
Xie, Jie
Wen, Kai
Zhang, Yongzhuo
Huang, Wenfeng
Mi, Wei
Peng, Ke
Dai, Xinhua
Fang, Xiang
author_sort Peng, Tao
collection PubMed
description The coronavirus disease 2019 (COVID-19) epidemic continues to ravage the world. In epidemic control, dealing with a large number of samples is a huge challenge. In this study, a point-of-care test (POCT) system was successfully developed and applied for rapid and accurate detection of immunoglobulin-G and -M against nucleocapsid protein (anti-N IgG/IgM) and receptor-binding domain in spike glycoprotein (anti-S-RBD IgG/IgM) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Any one of the IgG/IgM found in a sample was identified as positive. The POCT system contains colloidal gold-based lateral flow immunoassay test strips, homemade portable reader, and certified reference materials, which detected anti-N and anti-S-RBD IgG/IgM objectively in serum within 15 min. Receiver operating characteristic curve analysis was used to determine the optimal cutoff values, sensitivity, and specificity. It exhibited equal to or better performances than four approved commercial kits. Results of the system and chemiluminescence immunoassay kit detecting 108 suspicious samples had high consistency with kappa coefficient at 0.804 (P < 0.001). Besides, the levels and alterations of the IgG/IgM in an inpatient were primarily investigated by the POCT system. Those results suggested the POCT system possess the potential to contribute to rapid and accurate serological diagnosis and epidemiological survey of COVID-19.
format Online
Article
Text
id pubmed-7833039
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-78330392021-01-26 Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2 Peng, Tao Sui, Zhiwei Huang, Zhenghui Xie, Jie Wen, Kai Zhang, Yongzhuo Huang, Wenfeng Mi, Wei Peng, Ke Dai, Xinhua Fang, Xiang Sens Actuators B Chem Article The coronavirus disease 2019 (COVID-19) epidemic continues to ravage the world. In epidemic control, dealing with a large number of samples is a huge challenge. In this study, a point-of-care test (POCT) system was successfully developed and applied for rapid and accurate detection of immunoglobulin-G and -M against nucleocapsid protein (anti-N IgG/IgM) and receptor-binding domain in spike glycoprotein (anti-S-RBD IgG/IgM) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Any one of the IgG/IgM found in a sample was identified as positive. The POCT system contains colloidal gold-based lateral flow immunoassay test strips, homemade portable reader, and certified reference materials, which detected anti-N and anti-S-RBD IgG/IgM objectively in serum within 15 min. Receiver operating characteristic curve analysis was used to determine the optimal cutoff values, sensitivity, and specificity. It exhibited equal to or better performances than four approved commercial kits. Results of the system and chemiluminescence immunoassay kit detecting 108 suspicious samples had high consistency with kappa coefficient at 0.804 (P < 0.001). Besides, the levels and alterations of the IgG/IgM in an inpatient were primarily investigated by the POCT system. Those results suggested the POCT system possess the potential to contribute to rapid and accurate serological diagnosis and epidemiological survey of COVID-19. Elsevier B.V. 2021-03-15 2021-01-04 /pmc/articles/PMC7833039/ /pubmed/33519091 http://dx.doi.org/10.1016/j.snb.2020.129415 Text en © 2021 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Peng, Tao
Sui, Zhiwei
Huang, Zhenghui
Xie, Jie
Wen, Kai
Zhang, Yongzhuo
Huang, Wenfeng
Mi, Wei
Peng, Ke
Dai, Xinhua
Fang, Xiang
Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2
title Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2
title_full Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2
title_fullStr Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2
title_full_unstemmed Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2
title_short Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2
title_sort point-of-care test system for detection of immunoglobulin-g and -m against nucleocapsid protein and spike glycoprotein of sars-cov-2
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7833039/
https://www.ncbi.nlm.nih.gov/pubmed/33519091
http://dx.doi.org/10.1016/j.snb.2020.129415
work_keys_str_mv AT pengtao pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT suizhiwei pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT huangzhenghui pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT xiejie pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT wenkai pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT zhangyongzhuo pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT huangwenfeng pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT miwei pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT pengke pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT daixinhua pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2
AT fangxiang pointofcaretestsystemfordetectionofimmunoglobulingandmagainstnucleocapsidproteinandspikeglycoproteinofsarscov2