Cargando…
Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019
OBJECTIVE: The hypercoagulability seen in patients with novel coronavirus disease 2019 (COVID-19) likely contributes to the high temporary hemodialysis catheter (THDC) malfunction rate. We aim to evaluate prophylactic measures and their association with THDC patency. METHODS: A retrospective chart r...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Published by Elsevier Inc. on behalf of the Society for Vascular Surgery.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7833410/ https://www.ncbi.nlm.nih.gov/pubmed/33290813 http://dx.doi.org/10.1016/j.jvs.2020.11.033 |
_version_ | 1783642059098292224 |
---|---|
author | Kanitra, John J. Power, Alexandra D. Hayward, R. David Haouilou, Jimmy C. Edhayan, Elango |
author_facet | Kanitra, John J. Power, Alexandra D. Hayward, R. David Haouilou, Jimmy C. Edhayan, Elango |
author_sort | Kanitra, John J. |
collection | PubMed |
description | OBJECTIVE: The hypercoagulability seen in patients with novel coronavirus disease 2019 (COVID-19) likely contributes to the high temporary hemodialysis catheter (THDC) malfunction rate. We aim to evaluate prophylactic measures and their association with THDC patency. METHODS: A retrospective chart review of our institutions COVID-19 positive patients who required placement of a THDC between February 1 to April 30, 2020, was performed. The association between heparin locking, increased dosing of venous thromboembolism (VTE) prophylaxis and systemic anticoagulation on THDC patency was assessed. Proportional hazards modeling was used to perform a survival analysis to estimate the likelihood and timing of THDC malfunction with the three different prophylactic measures. We also determined the mortality, rate of THDC malfunction and its association with d-dimer levels. RESULTS: A total of 48 patients with a mortality rate of 71% were identified. THDC malfunction occurred in 31.3% of patients. Thirty-seven patients (77.1%) received heparin locking, 22 (45.8%) received systemic anticoagulation, and 38 (79.1%) received VTE prophylaxis. Overall, the rate of THDC malfunction was lower at a trend level of significance, with heparin vs saline locking (24.3% vs 54.6%; P = .058). The likelihood of THDC malfunction in the heparin locked group is lower than all other groups (hazard ratio [HR], 0.07; 95% confidence interval [CI], 0.01-0.45]; P = .005). The rate of malfunction in patients with subcutaneous heparin (SQH) 7500 U three times daily is significantly lower than of the rate for patients receiving none (HR, 0.03; 95% CI, 0.001-0.74; P = .032). A trend level significant association was found for SQH 5000 U vs none (P = .417) and SQH 7500 vs 5000 U (P = .059). Systemic anticoagulation did not affect the THDC malfunction rate (P = .240). Higher d-dimer levels were related to greater mortality (HR, 3.28; 95% CI, 1.16-9.28; P = .025), but were not significantly associated with THDC malfunction (HR, 1.79; 95% CI, 0.42, 7.71; P = .434). CONCLUSIONS: Locking THDCs with heparin is associated with a lower malfunction rate. Prospective randomized studies will be needed to confirm these findings to recommend locking THDC with heparin in patients with COVID-19. Increased VTE prophylaxis suggested a possible association with improved THDC patency, although the comparison lacked sufficient statistical power. |
format | Online Article Text |
id | pubmed-7833410 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Published by Elsevier Inc. on behalf of the Society for Vascular Surgery. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78334102021-01-26 Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 Kanitra, John J. Power, Alexandra D. Hayward, R. David Haouilou, Jimmy C. Edhayan, Elango J Vasc Surg COVID-19 and vascular disease OBJECTIVE: The hypercoagulability seen in patients with novel coronavirus disease 2019 (COVID-19) likely contributes to the high temporary hemodialysis catheter (THDC) malfunction rate. We aim to evaluate prophylactic measures and their association with THDC patency. METHODS: A retrospective chart review of our institutions COVID-19 positive patients who required placement of a THDC between February 1 to April 30, 2020, was performed. The association between heparin locking, increased dosing of venous thromboembolism (VTE) prophylaxis and systemic anticoagulation on THDC patency was assessed. Proportional hazards modeling was used to perform a survival analysis to estimate the likelihood and timing of THDC malfunction with the three different prophylactic measures. We also determined the mortality, rate of THDC malfunction and its association with d-dimer levels. RESULTS: A total of 48 patients with a mortality rate of 71% were identified. THDC malfunction occurred in 31.3% of patients. Thirty-seven patients (77.1%) received heparin locking, 22 (45.8%) received systemic anticoagulation, and 38 (79.1%) received VTE prophylaxis. Overall, the rate of THDC malfunction was lower at a trend level of significance, with heparin vs saline locking (24.3% vs 54.6%; P = .058). The likelihood of THDC malfunction in the heparin locked group is lower than all other groups (hazard ratio [HR], 0.07; 95% confidence interval [CI], 0.01-0.45]; P = .005). The rate of malfunction in patients with subcutaneous heparin (SQH) 7500 U three times daily is significantly lower than of the rate for patients receiving none (HR, 0.03; 95% CI, 0.001-0.74; P = .032). A trend level significant association was found for SQH 5000 U vs none (P = .417) and SQH 7500 vs 5000 U (P = .059). Systemic anticoagulation did not affect the THDC malfunction rate (P = .240). Higher d-dimer levels were related to greater mortality (HR, 3.28; 95% CI, 1.16-9.28; P = .025), but were not significantly associated with THDC malfunction (HR, 1.79; 95% CI, 0.42, 7.71; P = .434). CONCLUSIONS: Locking THDCs with heparin is associated with a lower malfunction rate. Prospective randomized studies will be needed to confirm these findings to recommend locking THDC with heparin in patients with COVID-19. Increased VTE prophylaxis suggested a possible association with improved THDC patency, although the comparison lacked sufficient statistical power. Published by Elsevier Inc. on behalf of the Society for Vascular Surgery. 2021-06 2020-12-05 /pmc/articles/PMC7833410/ /pubmed/33290813 http://dx.doi.org/10.1016/j.jvs.2020.11.033 Text en © 2020 Published by Elsevier Inc. on behalf of the Society for Vascular Surgery. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | COVID-19 and vascular disease Kanitra, John J. Power, Alexandra D. Hayward, R. David Haouilou, Jimmy C. Edhayan, Elango Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
title | Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
title_full | Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
title_fullStr | Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
title_full_unstemmed | Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
title_short | Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
title_sort | malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019 |
topic | COVID-19 and vascular disease |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7833410/ https://www.ncbi.nlm.nih.gov/pubmed/33290813 http://dx.doi.org/10.1016/j.jvs.2020.11.033 |
work_keys_str_mv | AT kanitrajohnj malfunctioningtemporaryhemodialysiscathetersinpatientswithnovelcoronavirusdisease2019 AT poweralexandrad malfunctioningtemporaryhemodialysiscathetersinpatientswithnovelcoronavirusdisease2019 AT haywardrdavid malfunctioningtemporaryhemodialysiscathetersinpatientswithnovelcoronavirusdisease2019 AT haouiloujimmyc malfunctioningtemporaryhemodialysiscathetersinpatientswithnovelcoronavirusdisease2019 AT edhayanelango malfunctioningtemporaryhemodialysiscathetersinpatientswithnovelcoronavirusdisease2019 |