Cargando…

IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?

BACKGROUND: It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. AIM: To compare performance assessment between 20G double fine needle biopsy (FNB) and co...

Descripción completa

Detalles Bibliográficos
Autores principales: ARDENGH, José Celso, BRUNALDI, Vitor Ottoboni, BRUNALDI, Mariângela Ottoboni, GASPAR, Alberto Facuri, LOPES-JÚNIOR, Jorge Resende, SANKARANKUTTY, Ajith Kumar, KEMP, Rafael, dos SANTOS, José Sebastião
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Colégio Brasileiro de Cirurgia Digestiva 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7836075/
https://www.ncbi.nlm.nih.gov/pubmed/33503114
http://dx.doi.org/10.1590/0102-672020200004e1554
_version_ 1783642673478893568
author ARDENGH, José Celso
BRUNALDI, Vitor Ottoboni
BRUNALDI, Mariângela Ottoboni
GASPAR, Alberto Facuri
LOPES-JÚNIOR, Jorge Resende
SANKARANKUTTY, Ajith Kumar
KEMP, Rafael
dos SANTOS, José Sebastião
author_facet ARDENGH, José Celso
BRUNALDI, Vitor Ottoboni
BRUNALDI, Mariângela Ottoboni
GASPAR, Alberto Facuri
LOPES-JÚNIOR, Jorge Resende
SANKARANKUTTY, Ajith Kumar
KEMP, Rafael
dos SANTOS, José Sebastião
author_sort ARDENGH, José Celso
collection PubMed
description BACKGROUND: It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. AIM: To compare performance assessment between 20G double fine needle biopsy (FNB) and conventional 22G fine needle aspiration (FNA) needles for endoscopic ultrasound (EUS)-guided biopsy. METHODS: This prospective study examined 20 patients who underwent the random puncture of solid pancreatic lesions with both needles and the analysis of tissue samples by a single pathologist. RESULTS: The ProCore 20G FNB needle provided more adequate tissue samples (16 vs. 9, p=0.039) with better cellularity quantitative scores (11 vs. 5, p=0.002) and larger diameter of the histological sample (1.51±1.3 mm vs. 0.94±0.55 mm, p=0.032) than the 22G needle. The technical success, puncture difficulty, and sample bleeding were similar between groups. The sensitivity, specificity, and diagnostic accuracy were 88.9%, 100%, and 90% and 77.8%, 100%, and 78.9% for the 20G and 22G needles, respectively. CONCLUSIONS: The samples obtained with the ProCore 20G FNB showed better histological parameters; although there was no difference in the diagnostic performance between the two needles, these findings may improve pathologist performance.
format Online
Article
Text
id pubmed-7836075
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Colégio Brasileiro de Cirurgia Digestiva
record_format MEDLINE/PubMed
spelling pubmed-78360752021-02-03 IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS? ARDENGH, José Celso BRUNALDI, Vitor Ottoboni BRUNALDI, Mariângela Ottoboni GASPAR, Alberto Facuri LOPES-JÚNIOR, Jorge Resende SANKARANKUTTY, Ajith Kumar KEMP, Rafael dos SANTOS, José Sebastião Arq Bras Cir Dig Original Article BACKGROUND: It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. AIM: To compare performance assessment between 20G double fine needle biopsy (FNB) and conventional 22G fine needle aspiration (FNA) needles for endoscopic ultrasound (EUS)-guided biopsy. METHODS: This prospective study examined 20 patients who underwent the random puncture of solid pancreatic lesions with both needles and the analysis of tissue samples by a single pathologist. RESULTS: The ProCore 20G FNB needle provided more adequate tissue samples (16 vs. 9, p=0.039) with better cellularity quantitative scores (11 vs. 5, p=0.002) and larger diameter of the histological sample (1.51±1.3 mm vs. 0.94±0.55 mm, p=0.032) than the 22G needle. The technical success, puncture difficulty, and sample bleeding were similar between groups. The sensitivity, specificity, and diagnostic accuracy were 88.9%, 100%, and 90% and 77.8%, 100%, and 78.9% for the 20G and 22G needles, respectively. CONCLUSIONS: The samples obtained with the ProCore 20G FNB showed better histological parameters; although there was no difference in the diagnostic performance between the two needles, these findings may improve pathologist performance. Colégio Brasileiro de Cirurgia Digestiva 2021-01-25 /pmc/articles/PMC7836075/ /pubmed/33503114 http://dx.doi.org/10.1590/0102-672020200004e1554 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Article
ARDENGH, José Celso
BRUNALDI, Vitor Ottoboni
BRUNALDI, Mariângela Ottoboni
GASPAR, Alberto Facuri
LOPES-JÚNIOR, Jorge Resende
SANKARANKUTTY, Ajith Kumar
KEMP, Rafael
dos SANTOS, José Sebastião
IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_full IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_fullStr IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_full_unstemmed IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_short IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_sort is the new procore 20g double forward-bevel needle capable to obtain better histological samples by endoscopic ultrasound for diagnosing solid pancreatic lesions?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7836075/
https://www.ncbi.nlm.nih.gov/pubmed/33503114
http://dx.doi.org/10.1590/0102-672020200004e1554
work_keys_str_mv AT ardenghjosecelso isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT brunaldivitorottoboni isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT brunaldimariangelaottoboni isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT gasparalbertofacuri isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT lopesjuniorjorgeresende isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT sankarankuttyajithkumar isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT kemprafael isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions
AT dossantosjosesebastiao isthenewprocore20gdoubleforwardbevelneedlecapabletoobtainbetterhistologicalsamplesbyendoscopicultrasoundfordiagnosingsolidpancreaticlesions