Cargando…

Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2

BACKGROUND: RT-PCR testing is crucial in the diagnostic of SARS-CoV-2 infection. The use of reliable and comparable PCR assays is a cornerstone to allow use of different PCR assays depending on the local equipment. In this work, we provide a comparison of the Cobas® (Roche) and the RealStar® assay (...

Descripción completa

Detalles Bibliográficos
Autores principales: Wirden, Marc, Feghoul, Linda, Bertine, Mélanie, Nere, Marie-Laure, Le Hingrat, Quentin, Abdi, Basma, Boutolleau, David, Ferre, Valentine Marie, Jary, Aude, Delaugerre, Constance, Marcelin, Anne-Genevieve, Descamps, Diane, Legoff, Jérôme, Visseaux, Benoit, Chaix, Marie-Laure
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7836314/
https://www.ncbi.nlm.nih.gov/pubmed/32769025
http://dx.doi.org/10.1016/j.jcv.2020.104573
_version_ 1783642721940930560
author Wirden, Marc
Feghoul, Linda
Bertine, Mélanie
Nere, Marie-Laure
Le Hingrat, Quentin
Abdi, Basma
Boutolleau, David
Ferre, Valentine Marie
Jary, Aude
Delaugerre, Constance
Marcelin, Anne-Genevieve
Descamps, Diane
Legoff, Jérôme
Visseaux, Benoit
Chaix, Marie-Laure
author_facet Wirden, Marc
Feghoul, Linda
Bertine, Mélanie
Nere, Marie-Laure
Le Hingrat, Quentin
Abdi, Basma
Boutolleau, David
Ferre, Valentine Marie
Jary, Aude
Delaugerre, Constance
Marcelin, Anne-Genevieve
Descamps, Diane
Legoff, Jérôme
Visseaux, Benoit
Chaix, Marie-Laure
author_sort Wirden, Marc
collection PubMed
description BACKGROUND: RT-PCR testing is crucial in the diagnostic of SARS-CoV-2 infection. The use of reliable and comparable PCR assays is a cornerstone to allow use of different PCR assays depending on the local equipment. In this work, we provide a comparison of the Cobas® (Roche) and the RealStar® assay (Altona). METHODS: Assessment of the two assays was performed prospectively in three reference Parisians hospitals, using 170 clinical samples. They were tested with the Cobas® assay, selected to obtain a distribution of cycle threshold (Ct) as large as possible, and tested with the RealStar assay with three largely available extraction platforms: QIAsymphony (Qiagen), MagNAPure (Roche) and NucliSENS-easyMag (BioMérieux). RESULTS: Overall, the agreement (positive for at least one gene) was 76 %. This rate differed considerably depending on the Cobas Ct values for gene E: below 35 (n = 91), the concordance was 99 %. Regarding the positive Ct values, linear regression analysis showed a coefficient of determination (R(2)) of 0.88 and the Deming regression line revealed a strong correlation with a slope of 1.023 and an intercept of -3.9. Bland-Altman analysis showed that the mean difference (Cobas® minus RealStar®) was + 3.3 Ct, with a SD of + 2.3 Ct. CONCLUSIONS: In this comparison, both RealStar® and Cobas® assays provided comparable qualitative results and a high correlation when both tests were positive. Discrepancies exist after 35 Ct and varied depending on the extraction system used for the RealStar® assay, probably due to a low viral load close to the detection limit of both assays.
format Online
Article
Text
id pubmed-7836314
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-78363142021-01-26 Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2 Wirden, Marc Feghoul, Linda Bertine, Mélanie Nere, Marie-Laure Le Hingrat, Quentin Abdi, Basma Boutolleau, David Ferre, Valentine Marie Jary, Aude Delaugerre, Constance Marcelin, Anne-Genevieve Descamps, Diane Legoff, Jérôme Visseaux, Benoit Chaix, Marie-Laure J Clin Virol Article BACKGROUND: RT-PCR testing is crucial in the diagnostic of SARS-CoV-2 infection. The use of reliable and comparable PCR assays is a cornerstone to allow use of different PCR assays depending on the local equipment. In this work, we provide a comparison of the Cobas® (Roche) and the RealStar® assay (Altona). METHODS: Assessment of the two assays was performed prospectively in three reference Parisians hospitals, using 170 clinical samples. They were tested with the Cobas® assay, selected to obtain a distribution of cycle threshold (Ct) as large as possible, and tested with the RealStar assay with three largely available extraction platforms: QIAsymphony (Qiagen), MagNAPure (Roche) and NucliSENS-easyMag (BioMérieux). RESULTS: Overall, the agreement (positive for at least one gene) was 76 %. This rate differed considerably depending on the Cobas Ct values for gene E: below 35 (n = 91), the concordance was 99 %. Regarding the positive Ct values, linear regression analysis showed a coefficient of determination (R(2)) of 0.88 and the Deming regression line revealed a strong correlation with a slope of 1.023 and an intercept of -3.9. Bland-Altman analysis showed that the mean difference (Cobas® minus RealStar®) was + 3.3 Ct, with a SD of + 2.3 Ct. CONCLUSIONS: In this comparison, both RealStar® and Cobas® assays provided comparable qualitative results and a high correlation when both tests were positive. Discrepancies exist after 35 Ct and varied depending on the extraction system used for the RealStar® assay, probably due to a low viral load close to the detection limit of both assays. Elsevier B.V. 2020-09 2020-07-31 /pmc/articles/PMC7836314/ /pubmed/32769025 http://dx.doi.org/10.1016/j.jcv.2020.104573 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Wirden, Marc
Feghoul, Linda
Bertine, Mélanie
Nere, Marie-Laure
Le Hingrat, Quentin
Abdi, Basma
Boutolleau, David
Ferre, Valentine Marie
Jary, Aude
Delaugerre, Constance
Marcelin, Anne-Genevieve
Descamps, Diane
Legoff, Jérôme
Visseaux, Benoit
Chaix, Marie-Laure
Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
title Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
title_full Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
title_fullStr Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
title_full_unstemmed Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
title_short Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
title_sort multicenter comparison of the cobas 6800 system with the realstar rt-pcr kit for the detection of sars-cov-2
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7836314/
https://www.ncbi.nlm.nih.gov/pubmed/32769025
http://dx.doi.org/10.1016/j.jcv.2020.104573
work_keys_str_mv AT wirdenmarc multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT feghoullinda multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT bertinemelanie multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT neremarielaure multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT lehingratquentin multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT abdibasma multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT boutolleaudavid multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT ferrevalentinemarie multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT jaryaude multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT delaugerreconstance multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT marcelinannegenevieve multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT descampsdiane multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT legoffjerome multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT visseauxbenoit multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2
AT chaixmarielaure multicentercomparisonofthecobas6800systemwiththerealstarrtpcrkitforthedetectionofsarscov2