Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system
BACKGROUND AND AIMS: Immediate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for preventing the spread of coronavirus disease 2019 (COVID-19). The LabTurbo AIO 48 system is an automated platform that allows nucleic acid extraction and sample analysis on the sa...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7836538/ https://www.ncbi.nlm.nih.gov/pubmed/33316217 http://dx.doi.org/10.1016/j.cca.2020.12.003 |
_version_ | 1783642771145359360 |
---|---|
author | Jian, Ming-Jr Chung, Hsing-Yi Chang, Chih-Kai Lin, Jung-Chung Yeh, Kuo-Ming Chiu, Sheng-Kang Wang, Yi-Hui Liao, Shu-Jung Li, Shih-Yi Hsieh, Shan-Shan Perng, Cherng-Lih Chang, Feng-Yee Shang, Hung-Sheng |
author_facet | Jian, Ming-Jr Chung, Hsing-Yi Chang, Chih-Kai Lin, Jung-Chung Yeh, Kuo-Ming Chiu, Sheng-Kang Wang, Yi-Hui Liao, Shu-Jung Li, Shih-Yi Hsieh, Shan-Shan Perng, Cherng-Lih Chang, Feng-Yee Shang, Hung-Sheng |
author_sort | Jian, Ming-Jr |
collection | PubMed |
description | BACKGROUND AND AIMS: Immediate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for preventing the spread of coronavirus disease 2019 (COVID-19). The LabTurbo AIO 48 system is an automated platform that allows nucleic acid extraction and sample analysis on the same instrument, producing faster results without affecting their accuracy. We aimed to independently evaluate the LabTurbo AIO 48 (all-in-one system) for SARS-CoV-2 detection. MATERIALS AND METHODS: Comparative limit of detection (LOD) was assessed on both the LabTurbo AIO 48 and current standard detection system based on real-time reverse transcriptase polymerase chain reaction (RT-PCR), using SARS-CoV-2 RNA control. Additional 125 primary clinical samples were assessed using both the protocols in parallel. RESULTS: The turnaround time from sample to results for 48 samples analyzed on LabTurbo AIO 48 was approximately 2.5 h, whereas that analyzed using the in-house RT-PCR protocol was 4.8 h. LabTurbo AIO 48 also demonstrated higher sensitivity than our reference RT-PCR assay, with a LOD of 9.4 copies/reaction. The overall percentage agreement between both the methods for 125 samples was 100%. CONCLUSION: LabTurbo AIO 48 is a robust detection option for SARS-CoV-2, allowing faster results and, consequently, aiding in better control and prevention of COVID-19. |
format | Online Article Text |
id | pubmed-7836538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78365382021-01-26 Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system Jian, Ming-Jr Chung, Hsing-Yi Chang, Chih-Kai Lin, Jung-Chung Yeh, Kuo-Ming Chiu, Sheng-Kang Wang, Yi-Hui Liao, Shu-Jung Li, Shih-Yi Hsieh, Shan-Shan Perng, Cherng-Lih Chang, Feng-Yee Shang, Hung-Sheng Clin Chim Acta Article BACKGROUND AND AIMS: Immediate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for preventing the spread of coronavirus disease 2019 (COVID-19). The LabTurbo AIO 48 system is an automated platform that allows nucleic acid extraction and sample analysis on the same instrument, producing faster results without affecting their accuracy. We aimed to independently evaluate the LabTurbo AIO 48 (all-in-one system) for SARS-CoV-2 detection. MATERIALS AND METHODS: Comparative limit of detection (LOD) was assessed on both the LabTurbo AIO 48 and current standard detection system based on real-time reverse transcriptase polymerase chain reaction (RT-PCR), using SARS-CoV-2 RNA control. Additional 125 primary clinical samples were assessed using both the protocols in parallel. RESULTS: The turnaround time from sample to results for 48 samples analyzed on LabTurbo AIO 48 was approximately 2.5 h, whereas that analyzed using the in-house RT-PCR protocol was 4.8 h. LabTurbo AIO 48 also demonstrated higher sensitivity than our reference RT-PCR assay, with a LOD of 9.4 copies/reaction. The overall percentage agreement between both the methods for 125 samples was 100%. CONCLUSION: LabTurbo AIO 48 is a robust detection option for SARS-CoV-2, allowing faster results and, consequently, aiding in better control and prevention of COVID-19. Elsevier B.V. 2021-03 2020-12-13 /pmc/articles/PMC7836538/ /pubmed/33316217 http://dx.doi.org/10.1016/j.cca.2020.12.003 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Jian, Ming-Jr Chung, Hsing-Yi Chang, Chih-Kai Lin, Jung-Chung Yeh, Kuo-Ming Chiu, Sheng-Kang Wang, Yi-Hui Liao, Shu-Jung Li, Shih-Yi Hsieh, Shan-Shan Perng, Cherng-Lih Chang, Feng-Yee Shang, Hung-Sheng Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system |
title | Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system |
title_full | Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system |
title_fullStr | Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system |
title_full_unstemmed | Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system |
title_short | Novel automated sample-to-result SARS-CoV-2 laboratory-developed RT-PCR assay for high-throughput testing using LabTurbo AIO 48 system |
title_sort | novel automated sample-to-result sars-cov-2 laboratory-developed rt-pcr assay for high-throughput testing using labturbo aio 48 system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7836538/ https://www.ncbi.nlm.nih.gov/pubmed/33316217 http://dx.doi.org/10.1016/j.cca.2020.12.003 |
work_keys_str_mv | AT jianmingjr novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT chunghsingyi novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT changchihkai novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT linjungchung novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT yehkuoming novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT chiushengkang novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT wangyihui novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT liaoshujung novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT lishihyi novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT hsiehshanshan novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT perngchernglih novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT changfengyee novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system AT shanghungsheng novelautomatedsampletoresultsarscov2laboratorydevelopedrtpcrassayforhighthroughputtestingusinglabturboaio48system |