Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty

Orthognathic surgery is a widely performed procedure to correct dentofacial deformities. Virtual treatment planning is an important preparation step. One advantage of the use of virtual treatment planning is the possibility to assess the accuracy of orthognathic surgery. In this study, a tool (Ortho...

Descripción completa

Detalles Bibliográficos
Autores principales: Baan, Frank, Sabelis, Juliana F., Schreurs, Ruud, van de Steeg, Gert, Xi, Tong, van Riet, Tom C. T., Becking, Alfred G., Maal, Thomas J. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7837467/
https://www.ncbi.nlm.nih.gov/pubmed/33497422
http://dx.doi.org/10.1371/journal.pone.0246196
_version_ 1783642960575856640
author Baan, Frank
Sabelis, Juliana F.
Schreurs, Ruud
van de Steeg, Gert
Xi, Tong
van Riet, Tom C. T.
Becking, Alfred G.
Maal, Thomas J. J.
author_facet Baan, Frank
Sabelis, Juliana F.
Schreurs, Ruud
van de Steeg, Gert
Xi, Tong
van Riet, Tom C. T.
Becking, Alfred G.
Maal, Thomas J. J.
author_sort Baan, Frank
collection PubMed
description Orthognathic surgery is a widely performed procedure to correct dentofacial deformities. Virtual treatment planning is an important preparation step. One advantage of the use of virtual treatment planning is the possibility to assess the accuracy of orthognathic surgery. In this study, a tool (OrthoGnathicAnalyser 2.0), which allows for quantification of the accuracy of orthognathic surgery, is presented and validated. In the OrthoGnathicAnalyser 2.0 the accuracy of the osseous chin can now be assessed which was not possible in the earlier version of the OrthoGnathicAnalyser. 30 patients who underwent bimaxillary surgery in combination with a genioplasty were selected from three different centers in the Netherlands. A pre-operative (CB)CT scan, virtual treatment planning and postoperative (CB)CT scan were required for assessing the accuracy of bimaxillary surgery. The preoperative and postoperative (CB)CT scans were aligned using voxel-based matching. Furthermore, voxel-based matching was used to align the pre-operative maxilla, mandible and rami towards their postoperative position whereas surface-based matching was used for aligning the pre-operative chin towards the postoperative position. The alignment resulted in a transformation matrix which contained the achieved translations and rotations. The achieved translations and rotations can be compared to planning values of the virtual treatment plan. To study the reproducibility, two independent observers processed all 30 patients to assess the inter-observer variability. One observer processed the patients twice to assess the intra-observer variability. Both the intra- and inter-observer variability showed high ICC values (> 0.92) and low measurement variations (< 0.673±0.684mm and < 0.654±0.824°). The results of this study show that the OrthoGnathicAnalyser 2.0 has an excellent reproducibility for quantification of skeletal movements between two (CB)CT scans.
format Online
Article
Text
id pubmed-7837467
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-78374672021-02-02 Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty Baan, Frank Sabelis, Juliana F. Schreurs, Ruud van de Steeg, Gert Xi, Tong van Riet, Tom C. T. Becking, Alfred G. Maal, Thomas J. J. PLoS One Research Article Orthognathic surgery is a widely performed procedure to correct dentofacial deformities. Virtual treatment planning is an important preparation step. One advantage of the use of virtual treatment planning is the possibility to assess the accuracy of orthognathic surgery. In this study, a tool (OrthoGnathicAnalyser 2.0), which allows for quantification of the accuracy of orthognathic surgery, is presented and validated. In the OrthoGnathicAnalyser 2.0 the accuracy of the osseous chin can now be assessed which was not possible in the earlier version of the OrthoGnathicAnalyser. 30 patients who underwent bimaxillary surgery in combination with a genioplasty were selected from three different centers in the Netherlands. A pre-operative (CB)CT scan, virtual treatment planning and postoperative (CB)CT scan were required for assessing the accuracy of bimaxillary surgery. The preoperative and postoperative (CB)CT scans were aligned using voxel-based matching. Furthermore, voxel-based matching was used to align the pre-operative maxilla, mandible and rami towards their postoperative position whereas surface-based matching was used for aligning the pre-operative chin towards the postoperative position. The alignment resulted in a transformation matrix which contained the achieved translations and rotations. The achieved translations and rotations can be compared to planning values of the virtual treatment plan. To study the reproducibility, two independent observers processed all 30 patients to assess the inter-observer variability. One observer processed the patients twice to assess the intra-observer variability. Both the intra- and inter-observer variability showed high ICC values (> 0.92) and low measurement variations (< 0.673±0.684mm and < 0.654±0.824°). The results of this study show that the OrthoGnathicAnalyser 2.0 has an excellent reproducibility for quantification of skeletal movements between two (CB)CT scans. Public Library of Science 2021-01-26 /pmc/articles/PMC7837467/ /pubmed/33497422 http://dx.doi.org/10.1371/journal.pone.0246196 Text en © 2021 Baan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Baan, Frank
Sabelis, Juliana F.
Schreurs, Ruud
van de Steeg, Gert
Xi, Tong
van Riet, Tom C. T.
Becking, Alfred G.
Maal, Thomas J. J.
Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty
title Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty
title_full Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty
title_fullStr Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty
title_full_unstemmed Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty
title_short Validation of the OrthoGnathicAnalyser 2.0—3D accuracy assessment tool for bimaxillary surgery and genioplasty
title_sort validation of the orthognathicanalyser 2.0—3d accuracy assessment tool for bimaxillary surgery and genioplasty
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7837467/
https://www.ncbi.nlm.nih.gov/pubmed/33497422
http://dx.doi.org/10.1371/journal.pone.0246196
work_keys_str_mv AT baanfrank validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT sabelisjulianaf validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT schreursruud validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT vandesteeggert validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT xitong validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT vanriettomct validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT beckingalfredg validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty
AT maalthomasjj validationoftheorthognathicanalyser203daccuracyassessmenttoolforbimaxillarysurgeryandgenioplasty