Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements

Extravasation is a common problem in radiopharmaceutical administration and can result in significant radiation dose to underlying tissue and skin. The resulting radiation effects are rarely studied and should be more fully evaluated to guide patient care and meet regulatory obligations. The purpose...

Descripción completa

Detalles Bibliográficos
Autores principales: Osborne, Dustin, Kiser, Jackson W., Knowland, Josh, Townsend, David, Fisher, Darrell R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7837744/
https://www.ncbi.nlm.nih.gov/pubmed/33443961
http://dx.doi.org/10.1097/HP.0000000000001375
_version_ 1783643013252120576
author Osborne, Dustin
Kiser, Jackson W.
Knowland, Josh
Townsend, David
Fisher, Darrell R.
author_facet Osborne, Dustin
Kiser, Jackson W.
Knowland, Josh
Townsend, David
Fisher, Darrell R.
author_sort Osborne, Dustin
collection PubMed
description Extravasation is a common problem in radiopharmaceutical administration and can result in significant radiation dose to underlying tissue and skin. The resulting radiation effects are rarely studied and should be more fully evaluated to guide patient care and meet regulatory obligations. The purpose of this work was to show that a dedicated radiopharmaceutical injection monitoring system can help clinicians characterize extravasations for calculating tissue and skin doses. We employed a commercially available radiopharmaceutical injection monitoring system to identify suspected extravasation of (18)F-fluorodeoxyglucose and (99m)Tc-methylene diphosphonate in 26 patients and to characterize their rates of biological clearance. We calculated the self-dose to infiltrated tissue using Monte Carlo simulation and standard MIRD dosimetry methods, and we used VARSKIN software to calculate the shallow dose equivalent to the epithelial basal-cell layer of overlying skin. For 26 patients, injection-site count rate data were used to characterize extravasation clearance. For each, the absorbed dose was calculated using representative tissue geometries. Resulting tissue-absorbed doses ranged from 0.6 to 11.2 Gy, and the shallow dose equivalent to a 10 cm(2) area of adjacent skin in these patients ranged from about 0.1 to 5.4 Sv. Extravasated injections of radiopharmaceuticals can result in unintentional doses that exceed well-established radiation protection and regulatory limits; they should be identified and characterized. An external injection monitoring system may help to promptly identify and characterize extravasations and improve dosimetry calculations. Patient-specific characterization can help clinicians determine extravasation severity and whether the patient should be followed for adverse tissue reactions that may present later in time.
format Online
Article
Text
id pubmed-7837744
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-78377442021-02-02 Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements Osborne, Dustin Kiser, Jackson W. Knowland, Josh Townsend, David Fisher, Darrell R. Health Phys Papers Extravasation is a common problem in radiopharmaceutical administration and can result in significant radiation dose to underlying tissue and skin. The resulting radiation effects are rarely studied and should be more fully evaluated to guide patient care and meet regulatory obligations. The purpose of this work was to show that a dedicated radiopharmaceutical injection monitoring system can help clinicians characterize extravasations for calculating tissue and skin doses. We employed a commercially available radiopharmaceutical injection monitoring system to identify suspected extravasation of (18)F-fluorodeoxyglucose and (99m)Tc-methylene diphosphonate in 26 patients and to characterize their rates of biological clearance. We calculated the self-dose to infiltrated tissue using Monte Carlo simulation and standard MIRD dosimetry methods, and we used VARSKIN software to calculate the shallow dose equivalent to the epithelial basal-cell layer of overlying skin. For 26 patients, injection-site count rate data were used to characterize extravasation clearance. For each, the absorbed dose was calculated using representative tissue geometries. Resulting tissue-absorbed doses ranged from 0.6 to 11.2 Gy, and the shallow dose equivalent to a 10 cm(2) area of adjacent skin in these patients ranged from about 0.1 to 5.4 Sv. Extravasated injections of radiopharmaceuticals can result in unintentional doses that exceed well-established radiation protection and regulatory limits; they should be identified and characterized. An external injection monitoring system may help to promptly identify and characterize extravasations and improve dosimetry calculations. Patient-specific characterization can help clinicians determine extravasation severity and whether the patient should be followed for adverse tissue reactions that may present later in time. Lippincott Williams & Wilkins 2021-03 2021-01-12 /pmc/articles/PMC7837744/ /pubmed/33443961 http://dx.doi.org/10.1097/HP.0000000000001375 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Health Physics Society. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Papers
Osborne, Dustin
Kiser, Jackson W.
Knowland, Josh
Townsend, David
Fisher, Darrell R.
Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements
title Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements
title_full Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements
title_fullStr Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements
title_full_unstemmed Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements
title_short Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements
title_sort patient-specific extravasation dosimetry using uptake probe measurements
topic Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7837744/
https://www.ncbi.nlm.nih.gov/pubmed/33443961
http://dx.doi.org/10.1097/HP.0000000000001375
work_keys_str_mv AT osbornedustin patientspecificextravasationdosimetryusinguptakeprobemeasurements
AT kiserjacksonw patientspecificextravasationdosimetryusinguptakeprobemeasurements
AT knowlandjosh patientspecificextravasationdosimetryusinguptakeprobemeasurements
AT townsenddavid patientspecificextravasationdosimetryusinguptakeprobemeasurements
AT fisherdarrellr patientspecificextravasationdosimetryusinguptakeprobemeasurements