Cargando…
Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis
BACKGROUND: Computer-aided detection (CAD) system for accurate and automated prostate cancer (PCa) diagnosis have been developed, however, the diagnostic test accuracy of different CAD systems is still controversial. This systematic review aimed to assess the diagnostic accuracy of CAD systems based...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7837946/ https://www.ncbi.nlm.nih.gov/pubmed/33545946 http://dx.doi.org/10.1097/MD.0000000000023817 |
_version_ | 1783643060769390592 |
---|---|
author | Xing, Xiping Zhao, Xinke Wei, Huiping Li, Yingdong |
author_facet | Xing, Xiping Zhao, Xinke Wei, Huiping Li, Yingdong |
author_sort | Xing, Xiping |
collection | PubMed |
description | BACKGROUND: Computer-aided detection (CAD) system for accurate and automated prostate cancer (PCa) diagnosis have been developed, however, the diagnostic test accuracy of different CAD systems is still controversial. This systematic review aimed to assess the diagnostic accuracy of CAD systems based on magnetic resonance imaging for PCa. METHODS: Cochrane library, PubMed, EMBASE and China Biology Medicine disc were systematically searched until March 2019 for original diagnostic studies. Two independent reviewers selected studies on CAD based on magnetic resonance imaging diagnosis of PCa and extracted the requisite data. Pooled sensitivity, specificity, and the area under the summary receiver operating characteristic curve were calculated to estimate the diagnostic accuracy of CAD system. RESULTS: Fifteen studies involving 1945 patients were included in our analysis. The diagnostic meta-analysis showed that overall sensitivity of CAD system ranged from 0.47 to 1.00 and, specificity from 0.47 to 0.89. The pooled sensitivity of CAD system was 0.87 (95% CI: 0.76–0.94), pooled specificity 0.76 (95% CI: 0.62–0.85), and the area under curve (AUC) 0.89 (95% CI: 0.86–0.91). Subgroup analysis showed that the support vector machines produced the best AUC among the CAD classifiers, with sensitivity ranging from 0.87 to 0.92, and specificity from 0.47 to 0.95. Among different zones of prostate, CAD system produced the best AUC in the transitional zone than the peripheral zone and central gland; sensitivity ranged from 0.89 to 1.00, and specificity from 0.38 to 0.85. CONCLUSIONS: CAD system can help improve the diagnostic accuracy of PCa especially using the support vector machines classifier. Whether the performance of the CAD system depends on the specific locations of the prostate needs further investigation. |
format | Online Article Text |
id | pubmed-7837946 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-78379462021-01-27 Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis Xing, Xiping Zhao, Xinke Wei, Huiping Li, Yingdong Medicine (Baltimore) 5700 BACKGROUND: Computer-aided detection (CAD) system for accurate and automated prostate cancer (PCa) diagnosis have been developed, however, the diagnostic test accuracy of different CAD systems is still controversial. This systematic review aimed to assess the diagnostic accuracy of CAD systems based on magnetic resonance imaging for PCa. METHODS: Cochrane library, PubMed, EMBASE and China Biology Medicine disc were systematically searched until March 2019 for original diagnostic studies. Two independent reviewers selected studies on CAD based on magnetic resonance imaging diagnosis of PCa and extracted the requisite data. Pooled sensitivity, specificity, and the area under the summary receiver operating characteristic curve were calculated to estimate the diagnostic accuracy of CAD system. RESULTS: Fifteen studies involving 1945 patients were included in our analysis. The diagnostic meta-analysis showed that overall sensitivity of CAD system ranged from 0.47 to 1.00 and, specificity from 0.47 to 0.89. The pooled sensitivity of CAD system was 0.87 (95% CI: 0.76–0.94), pooled specificity 0.76 (95% CI: 0.62–0.85), and the area under curve (AUC) 0.89 (95% CI: 0.86–0.91). Subgroup analysis showed that the support vector machines produced the best AUC among the CAD classifiers, with sensitivity ranging from 0.87 to 0.92, and specificity from 0.47 to 0.95. Among different zones of prostate, CAD system produced the best AUC in the transitional zone than the peripheral zone and central gland; sensitivity ranged from 0.89 to 1.00, and specificity from 0.38 to 0.85. CONCLUSIONS: CAD system can help improve the diagnostic accuracy of PCa especially using the support vector machines classifier. Whether the performance of the CAD system depends on the specific locations of the prostate needs further investigation. Lippincott Williams & Wilkins 2021-01-22 /pmc/articles/PMC7837946/ /pubmed/33545946 http://dx.doi.org/10.1097/MD.0000000000023817 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 5700 Xing, Xiping Zhao, Xinke Wei, Huiping Li, Yingdong Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis |
title | Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis |
title_full | Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis |
title_fullStr | Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis |
title_full_unstemmed | Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis |
title_short | Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis |
title_sort | diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: a systematic review with diagnostic meta-analysis |
topic | 5700 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7837946/ https://www.ncbi.nlm.nih.gov/pubmed/33545946 http://dx.doi.org/10.1097/MD.0000000000023817 |
work_keys_str_mv | AT xingxiping diagnosticaccuracyofdifferentcomputeraideddiagnosticsystemsforprostatecancerbasedonmagneticresonanceimagingasystematicreviewwithdiagnosticmetaanalysis AT zhaoxinke diagnosticaccuracyofdifferentcomputeraideddiagnosticsystemsforprostatecancerbasedonmagneticresonanceimagingasystematicreviewwithdiagnosticmetaanalysis AT weihuiping diagnosticaccuracyofdifferentcomputeraideddiagnosticsystemsforprostatecancerbasedonmagneticresonanceimagingasystematicreviewwithdiagnosticmetaanalysis AT liyingdong diagnosticaccuracyofdifferentcomputeraideddiagnosticsystemsforprostatecancerbasedonmagneticresonanceimagingasystematicreviewwithdiagnosticmetaanalysis |