Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry

IMPORTANCE: Frequent right ventricular (RV) pacing can cause and exacerbate heart failure. Cardiac resynchronization therapy (CRT) has been shown to be associated with improved outcomes among patients with reduced left ventricular ejection fraction who need frequent RV pacing, but the patterns of us...

Descripción completa

Detalles Bibliográficos
Autores principales: Borne, Ryan T., Masoudi, Frederick A., Curtis, Jeptha P., Zipse, Matthew M., Sandhu, Amneet, Hsu, Jonathan C., Peterson, Pamela N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7838925/
https://www.ncbi.nlm.nih.gov/pubmed/33496796
http://dx.doi.org/10.1001/jamanetworkopen.2020.35470
_version_ 1783643292428140544
author Borne, Ryan T.
Masoudi, Frederick A.
Curtis, Jeptha P.
Zipse, Matthew M.
Sandhu, Amneet
Hsu, Jonathan C.
Peterson, Pamela N.
author_facet Borne, Ryan T.
Masoudi, Frederick A.
Curtis, Jeptha P.
Zipse, Matthew M.
Sandhu, Amneet
Hsu, Jonathan C.
Peterson, Pamela N.
author_sort Borne, Ryan T.
collection PubMed
description IMPORTANCE: Frequent right ventricular (RV) pacing can cause and exacerbate heart failure. Cardiac resynchronization therapy (CRT) has been shown to be associated with improved outcomes among patients with reduced left ventricular ejection fraction who need frequent RV pacing, but the patterns of use of CRT vs dual chamber (DC) devices and the associated outcomes among these patients in clinical practice is not known. OBJECTIVE: To assess outcomes, variability in use of device type, and trends in use of device type over time among patients undergoing implantable cardioverter defibrillator (ICD) implantation who were likely to require frequent RV pacing but who did not have a class I indication for CRT. DESIGN, SETTING, AND PARTICIPANTS: This retrospective cohort study used the National Cardiovascular Data Registry (NCDR) ICD Registry. A total of 3100 Medicare beneficiaries undergoing first-time implantation of CRT defibrillator (CRT-D) or DC-ICD from 2010 to 2016 who had a class I or II guideline ventricular bradycardia pacing indication but not a class I indication for CRT were included. Data were analyzed from August 2018 to October 2019. EXPOSURES: Implantation of a CRT-D or DC-ICD. MAIN OUTCOMES AND MEASURES: All-cause mortality, heart failure hospitalization, and complications were ascertained from Medicare claims data. Multivariable Cox proportional hazards models and Fine-Gray models were used to evaluate 1-year mortality and heart failure hospitalization, respectively. Multivariable logistic regression was used to evaluate 30-day and 90-day complications. All models accounted for clustering. The median odds ratio (MOR) was used to assess variability and represents the odds that a randomly selected patient receiving CRT-D at a hospital with high implant rates would receive CRT-D if they had been treated at a hospital with low CRT-D implant rates. RESULTS: A total of 3100 individuals were included. The mean (SD) age was 76.3 (6.4) years, and 2500 (80.6%) were men. The 1698 patients (54.7%) receiving CRT-D were more likely than those receiving DC-ICD to have third-degree atrioventricular block (828 [48.8%] vs 432 [30.8%]; P < .001), nonischemic cardiomyopathy (508 [29.9%] vs 255 [18.2%]; P < .001), and prior heart failure hospitalizations (703 [41.4%] vs 421 [30.0%]; P < .001). Following adjustment, CRT-D was associated with lower 1-year mortality (hazard ratio [HR], 0.70; 95% CI, 0.57-0.87; P = .001) and heart failure hospitalization (subdistribution HR, 0.77; 95% CI, 0.61-0.97; P = .02) and no difference in complications compared with DC-ICD. Hospital variation in use of CRT was present (MOR, 2.00), and the use of CRT in this cohort was higher over time (654 of 1351 [48.4%] in 2010 vs 362 of 594 [60.9%] in 2016; P < .001). CONCLUSIONS AND RELEVANCE: In this cohort study of older patients in contemporary practice undergoing ICD implantation with a bradycardia pacing indication but without a class I indication for CRT, CRT-D was associated with better outcomes compared with DC devices. Variability in use of device type was observed, and the rate of CRT implantation increased over time.
format Online
Article
Text
id pubmed-7838925
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Medical Association
record_format MEDLINE/PubMed
spelling pubmed-78389252021-02-04 Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry Borne, Ryan T. Masoudi, Frederick A. Curtis, Jeptha P. Zipse, Matthew M. Sandhu, Amneet Hsu, Jonathan C. Peterson, Pamela N. JAMA Netw Open Original Investigation IMPORTANCE: Frequent right ventricular (RV) pacing can cause and exacerbate heart failure. Cardiac resynchronization therapy (CRT) has been shown to be associated with improved outcomes among patients with reduced left ventricular ejection fraction who need frequent RV pacing, but the patterns of use of CRT vs dual chamber (DC) devices and the associated outcomes among these patients in clinical practice is not known. OBJECTIVE: To assess outcomes, variability in use of device type, and trends in use of device type over time among patients undergoing implantable cardioverter defibrillator (ICD) implantation who were likely to require frequent RV pacing but who did not have a class I indication for CRT. DESIGN, SETTING, AND PARTICIPANTS: This retrospective cohort study used the National Cardiovascular Data Registry (NCDR) ICD Registry. A total of 3100 Medicare beneficiaries undergoing first-time implantation of CRT defibrillator (CRT-D) or DC-ICD from 2010 to 2016 who had a class I or II guideline ventricular bradycardia pacing indication but not a class I indication for CRT were included. Data were analyzed from August 2018 to October 2019. EXPOSURES: Implantation of a CRT-D or DC-ICD. MAIN OUTCOMES AND MEASURES: All-cause mortality, heart failure hospitalization, and complications were ascertained from Medicare claims data. Multivariable Cox proportional hazards models and Fine-Gray models were used to evaluate 1-year mortality and heart failure hospitalization, respectively. Multivariable logistic regression was used to evaluate 30-day and 90-day complications. All models accounted for clustering. The median odds ratio (MOR) was used to assess variability and represents the odds that a randomly selected patient receiving CRT-D at a hospital with high implant rates would receive CRT-D if they had been treated at a hospital with low CRT-D implant rates. RESULTS: A total of 3100 individuals were included. The mean (SD) age was 76.3 (6.4) years, and 2500 (80.6%) were men. The 1698 patients (54.7%) receiving CRT-D were more likely than those receiving DC-ICD to have third-degree atrioventricular block (828 [48.8%] vs 432 [30.8%]; P < .001), nonischemic cardiomyopathy (508 [29.9%] vs 255 [18.2%]; P < .001), and prior heart failure hospitalizations (703 [41.4%] vs 421 [30.0%]; P < .001). Following adjustment, CRT-D was associated with lower 1-year mortality (hazard ratio [HR], 0.70; 95% CI, 0.57-0.87; P = .001) and heart failure hospitalization (subdistribution HR, 0.77; 95% CI, 0.61-0.97; P = .02) and no difference in complications compared with DC-ICD. Hospital variation in use of CRT was present (MOR, 2.00), and the use of CRT in this cohort was higher over time (654 of 1351 [48.4%] in 2010 vs 362 of 594 [60.9%] in 2016; P < .001). CONCLUSIONS AND RELEVANCE: In this cohort study of older patients in contemporary practice undergoing ICD implantation with a bradycardia pacing indication but without a class I indication for CRT, CRT-D was associated with better outcomes compared with DC devices. Variability in use of device type was observed, and the rate of CRT implantation increased over time. American Medical Association 2021-01-26 /pmc/articles/PMC7838925/ /pubmed/33496796 http://dx.doi.org/10.1001/jamanetworkopen.2020.35470 Text en Copyright 2021 Borne RT et al. JAMA Network Open. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the CC-BY License.
spellingShingle Original Investigation
Borne, Ryan T.
Masoudi, Frederick A.
Curtis, Jeptha P.
Zipse, Matthew M.
Sandhu, Amneet
Hsu, Jonathan C.
Peterson, Pamela N.
Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
title Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
title_full Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
title_fullStr Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
title_full_unstemmed Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
title_short Use and Outcomes of Dual Chamber or Cardiac Resynchronization Therapy Defibrillators Among Older Patients Requiring Ventricular Pacing in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry
title_sort use and outcomes of dual chamber or cardiac resynchronization therapy defibrillators among older patients requiring ventricular pacing in the national cardiovascular data registry implantable cardioverter defibrillator registry
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7838925/
https://www.ncbi.nlm.nih.gov/pubmed/33496796
http://dx.doi.org/10.1001/jamanetworkopen.2020.35470
work_keys_str_mv AT borneryant useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry
AT masoudifredericka useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry
AT curtisjepthap useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry
AT zipsematthewm useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry
AT sandhuamneet useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry
AT hsujonathanc useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry
AT petersonpamelan useandoutcomesofdualchamberorcardiacresynchronizationtherapydefibrillatorsamongolderpatientsrequiringventricularpacinginthenationalcardiovasculardataregistryimplantablecardioverterdefibrillatorregistry