Cargando…
A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring
This paper reports a flexible electronics-based epidermal biomicrofluidics technique for clinical continuous blood glucose monitoring, overcoming the drawback of the present wearables, unreliable measurements. A thermal activation method is proposed to improve the efficiency of transdermal interstit...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Association for the Advancement of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7840141/ https://www.ncbi.nlm.nih.gov/pubmed/33571117 http://dx.doi.org/10.1126/sciadv.abd0199 |
_version_ | 1783643515844034560 |
---|---|
author | Pu, Z. Zhang, X. Yu, H. Tu, J. Chen, H. Liu, Y. Su, X. Wang, R. Zhang, L. Li, D. |
author_facet | Pu, Z. Zhang, X. Yu, H. Tu, J. Chen, H. Liu, Y. Su, X. Wang, R. Zhang, L. Li, D. |
author_sort | Pu, Z. |
collection | PubMed |
description | This paper reports a flexible electronics-based epidermal biomicrofluidics technique for clinical continuous blood glucose monitoring, overcoming the drawback of the present wearables, unreliable measurements. A thermal activation method is proposed to improve the efficiency of transdermal interstitial fluid (ISF) extraction, enabling extraction with a low current density to notably reduce skin irritation. An Na(+) sensor and a correction model are proposed to eliminate the effect of individual differences, which leads to fluctuations in the amount of ISF extraction. An electrochemical sensor with a 3D nanostructured working electrode surface is designed to enable precise in situ glucose measurement. A differential structure is proposed to eliminate the effect of passive perspiration, which leads to inaccurate blood glucose prediction. Fabrications of the epidermal biomicrofluidic device including formation of flexible electrodes, nanomaterial modification, and enzyme immobilization are fully realized by inkjet printing to enable facile manufacturing with low cost, which benefits practical production. |
format | Online Article Text |
id | pubmed-7840141 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Association for the Advancement of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-78401412021-02-05 A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring Pu, Z. Zhang, X. Yu, H. Tu, J. Chen, H. Liu, Y. Su, X. Wang, R. Zhang, L. Li, D. Sci Adv Research Articles This paper reports a flexible electronics-based epidermal biomicrofluidics technique for clinical continuous blood glucose monitoring, overcoming the drawback of the present wearables, unreliable measurements. A thermal activation method is proposed to improve the efficiency of transdermal interstitial fluid (ISF) extraction, enabling extraction with a low current density to notably reduce skin irritation. An Na(+) sensor and a correction model are proposed to eliminate the effect of individual differences, which leads to fluctuations in the amount of ISF extraction. An electrochemical sensor with a 3D nanostructured working electrode surface is designed to enable precise in situ glucose measurement. A differential structure is proposed to eliminate the effect of passive perspiration, which leads to inaccurate blood glucose prediction. Fabrications of the epidermal biomicrofluidic device including formation of flexible electrodes, nanomaterial modification, and enzyme immobilization are fully realized by inkjet printing to enable facile manufacturing with low cost, which benefits practical production. American Association for the Advancement of Science 2021-01-27 /pmc/articles/PMC7840141/ /pubmed/33571117 http://dx.doi.org/10.1126/sciadv.abd0199 Text en Copyright © 2021 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works. Distributed under a Creative Commons Attribution NonCommercial License 4.0 (CC BY-NC). https://creativecommons.org/licenses/by-nc/4.0/ https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial license (https://creativecommons.org/licenses/by-nc/4.0/) , which permits use, distribution, and reproduction in any medium, so long as the resultant use is not for commercial advantage and provided the original work is properly cited. |
spellingShingle | Research Articles Pu, Z. Zhang, X. Yu, H. Tu, J. Chen, H. Liu, Y. Su, X. Wang, R. Zhang, L. Li, D. A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
title | A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
title_full | A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
title_fullStr | A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
title_full_unstemmed | A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
title_short | A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
title_sort | thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7840141/ https://www.ncbi.nlm.nih.gov/pubmed/33571117 http://dx.doi.org/10.1126/sciadv.abd0199 |
work_keys_str_mv | AT puz athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT zhangx athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT yuh athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT tuj athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT chenh athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT liuy athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT sux athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT wangr athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT zhangl athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT lid athermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT puz thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT zhangx thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT yuh thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT tuj thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT chenh thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT liuy thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT sux thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT wangr thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT zhangl thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring AT lid thermalactivatedanddifferentialselfcalibratedflexibleepidermalbiomicrofluidicdeviceforwearableaccuratebloodglucosemonitoring |