Cargando…

Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate

It is necessary to consider how a glove box’s confinement function will be lost when evaluating the amount of radioactive material leaking from a nuclear facility during a fire. In this study, we build a model that consistently explains the weight loss of glove box materials because of heat input fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohno, Takuya, Tashiro, Shinsuke, Amano, Yuki, Yoshida, Naoki, Yoshida, Ryoichiro, Abe, Hitoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7842909/
https://www.ncbi.nlm.nih.gov/pubmed/33507991
http://dx.doi.org/10.1371/journal.pone.0245303
_version_ 1783644034193948672
author Ohno, Takuya
Tashiro, Shinsuke
Amano, Yuki
Yoshida, Naoki
Yoshida, Ryoichiro
Abe, Hitoshi
author_facet Ohno, Takuya
Tashiro, Shinsuke
Amano, Yuki
Yoshida, Naoki
Yoshida, Ryoichiro
Abe, Hitoshi
author_sort Ohno, Takuya
collection PubMed
description It is necessary to consider how a glove box’s confinement function will be lost when evaluating the amount of radioactive material leaking from a nuclear facility during a fire. In this study, we build a model that consistently explains the weight loss of glove box materials because of heat input from a flame and accompanying generation of the pyrolysis gas. The weight loss suggests thinning of the glove box housing, and the generation of pyrolysis gas suggests the possibility of fire spreading. The target was polymethyl methacrylate (PMMA), used as the glove box panel. Thermal gravimetric tests on PMMA determined the parameters to be substituted in the Arrhenius equation for predicting the weight loss in pyrolysis. The pyrolysis process of PMMA was divided into 3 stages with activation energies of 62 kJ/mol, 250 kJ/mol, and 265 kJ/mol. Furthermore, quantifying the gas composition revealed that the composition of the pyrolysis gas released from PMMA can be approximated as 100% methyl methacrylate. This result suggests that the released amount of methyl methacrylate can be estimated by the Arrhenius equation. To investigate the validity of such estimation, a sealed vessel test was performed. In this test, we observed increase of the number of gas molecules during the pyrolysis as internal pressure change of the vessel. The number of gas molecules was similar to that estimated from the Arrhenius equation, and indicated the validity of our method. Moreover, we also performed the same tests on bisphenol-A-polycarbonate (PC) for comparison. In case of PC, the number of gas molecules obtained in the vessel test was higher than the estimated value.
format Online
Article
Text
id pubmed-7842909
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-78429092021-02-02 Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate Ohno, Takuya Tashiro, Shinsuke Amano, Yuki Yoshida, Naoki Yoshida, Ryoichiro Abe, Hitoshi PLoS One Research Article It is necessary to consider how a glove box’s confinement function will be lost when evaluating the amount of radioactive material leaking from a nuclear facility during a fire. In this study, we build a model that consistently explains the weight loss of glove box materials because of heat input from a flame and accompanying generation of the pyrolysis gas. The weight loss suggests thinning of the glove box housing, and the generation of pyrolysis gas suggests the possibility of fire spreading. The target was polymethyl methacrylate (PMMA), used as the glove box panel. Thermal gravimetric tests on PMMA determined the parameters to be substituted in the Arrhenius equation for predicting the weight loss in pyrolysis. The pyrolysis process of PMMA was divided into 3 stages with activation energies of 62 kJ/mol, 250 kJ/mol, and 265 kJ/mol. Furthermore, quantifying the gas composition revealed that the composition of the pyrolysis gas released from PMMA can be approximated as 100% methyl methacrylate. This result suggests that the released amount of methyl methacrylate can be estimated by the Arrhenius equation. To investigate the validity of such estimation, a sealed vessel test was performed. In this test, we observed increase of the number of gas molecules during the pyrolysis as internal pressure change of the vessel. The number of gas molecules was similar to that estimated from the Arrhenius equation, and indicated the validity of our method. Moreover, we also performed the same tests on bisphenol-A-polycarbonate (PC) for comparison. In case of PC, the number of gas molecules obtained in the vessel test was higher than the estimated value. Public Library of Science 2021-01-28 /pmc/articles/PMC7842909/ /pubmed/33507991 http://dx.doi.org/10.1371/journal.pone.0245303 Text en © 2021 Ohno et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ohno, Takuya
Tashiro, Shinsuke
Amano, Yuki
Yoshida, Naoki
Yoshida, Ryoichiro
Abe, Hitoshi
Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate
title Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate
title_full Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate
title_fullStr Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate
title_full_unstemmed Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate
title_short Consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—A case for glovebox panel materials such as polymethyl methacrylate
title_sort consistent modelling of material weight loss and gas release due to pyrolysis and conducting benchmark tests of the model—a case for glovebox panel materials such as polymethyl methacrylate
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7842909/
https://www.ncbi.nlm.nih.gov/pubmed/33507991
http://dx.doi.org/10.1371/journal.pone.0245303
work_keys_str_mv AT ohnotakuya consistentmodellingofmaterialweightlossandgasreleaseduetopyrolysisandconductingbenchmarktestsofthemodelacaseforgloveboxpanelmaterialssuchaspolymethylmethacrylate
AT tashiroshinsuke consistentmodellingofmaterialweightlossandgasreleaseduetopyrolysisandconductingbenchmarktestsofthemodelacaseforgloveboxpanelmaterialssuchaspolymethylmethacrylate
AT amanoyuki consistentmodellingofmaterialweightlossandgasreleaseduetopyrolysisandconductingbenchmarktestsofthemodelacaseforgloveboxpanelmaterialssuchaspolymethylmethacrylate
AT yoshidanaoki consistentmodellingofmaterialweightlossandgasreleaseduetopyrolysisandconductingbenchmarktestsofthemodelacaseforgloveboxpanelmaterialssuchaspolymethylmethacrylate
AT yoshidaryoichiro consistentmodellingofmaterialweightlossandgasreleaseduetopyrolysisandconductingbenchmarktestsofthemodelacaseforgloveboxpanelmaterialssuchaspolymethylmethacrylate
AT abehitoshi consistentmodellingofmaterialweightlossandgasreleaseduetopyrolysisandconductingbenchmarktestsofthemodelacaseforgloveboxpanelmaterialssuchaspolymethylmethacrylate