Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis

Scaphoid fractures are the most common carpal fractures. Diagnosing scaphoid fractures is challenging. Recently, cone-beam computed tomography (CBCT) has been shown to be a promising strategy for diagnosing scaphoid fractures. The diagnostic performance of CBCT remains inconclusive in the literature...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Ta-Wei, Lin, Yen-Yue, Hsu, Shih-Chang, Chu, Karen Chia-Wen, Hsiao, Chih-Wei, Hsu, Chin-Wang, Bai, Chyi-Huey, Chang, Cheng-Kuang, Hsu, Yuan-Pin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7843979/
https://www.ncbi.nlm.nih.gov/pubmed/33510347
http://dx.doi.org/10.1038/s41598-021-82351-9
_version_ 1783644239856402432
author Yang, Ta-Wei
Lin, Yen-Yue
Hsu, Shih-Chang
Chu, Karen Chia-Wen
Hsiao, Chih-Wei
Hsu, Chin-Wang
Bai, Chyi-Huey
Chang, Cheng-Kuang
Hsu, Yuan-Pin
author_facet Yang, Ta-Wei
Lin, Yen-Yue
Hsu, Shih-Chang
Chu, Karen Chia-Wen
Hsiao, Chih-Wei
Hsu, Chin-Wang
Bai, Chyi-Huey
Chang, Cheng-Kuang
Hsu, Yuan-Pin
author_sort Yang, Ta-Wei
collection PubMed
description Scaphoid fractures are the most common carpal fractures. Diagnosing scaphoid fractures is challenging. Recently, cone-beam computed tomography (CBCT) has been shown to be a promising strategy for diagnosing scaphoid fractures. The diagnostic performance of CBCT remains inconclusive in the literature. Through a systematic review and meta-analysis, our study aims to determine the diagnostic performance of CBCT for diagnosing scaphoid fractures. Five databases were searched up to March 25, 2020. We included prospective and retrospective studies describing the diagnostic accuracy of CBCT for scaphoid fractures in adult patients. QUADAS-2 tool was used to assess the quality of the included studies. Four studies (n = 350) were included in the meta-analysis. Three of the four studies had high bias risk. The result showed that CBCT had a pooled sensitivity of 0.88 and a pooled specificity of 0.99 for scaphoid fracture diagnosis. The heterogeneities of sensitivity and specificity were substantial. The area under the summary receiver operating characteristic curve was 0.98. No significant publication bias was observed. The result suggested that the diagnostic performance of CBCT for scaphoid fracture was excellent. The certainty of current evidence is low. Further well-designed studies with large sample sizes are warranted to confirm this finding.
format Online
Article
Text
id pubmed-7843979
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-78439792021-01-29 Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis Yang, Ta-Wei Lin, Yen-Yue Hsu, Shih-Chang Chu, Karen Chia-Wen Hsiao, Chih-Wei Hsu, Chin-Wang Bai, Chyi-Huey Chang, Cheng-Kuang Hsu, Yuan-Pin Sci Rep Article Scaphoid fractures are the most common carpal fractures. Diagnosing scaphoid fractures is challenging. Recently, cone-beam computed tomography (CBCT) has been shown to be a promising strategy for diagnosing scaphoid fractures. The diagnostic performance of CBCT remains inconclusive in the literature. Through a systematic review and meta-analysis, our study aims to determine the diagnostic performance of CBCT for diagnosing scaphoid fractures. Five databases were searched up to March 25, 2020. We included prospective and retrospective studies describing the diagnostic accuracy of CBCT for scaphoid fractures in adult patients. QUADAS-2 tool was used to assess the quality of the included studies. Four studies (n = 350) were included in the meta-analysis. Three of the four studies had high bias risk. The result showed that CBCT had a pooled sensitivity of 0.88 and a pooled specificity of 0.99 for scaphoid fracture diagnosis. The heterogeneities of sensitivity and specificity were substantial. The area under the summary receiver operating characteristic curve was 0.98. No significant publication bias was observed. The result suggested that the diagnostic performance of CBCT for scaphoid fracture was excellent. The certainty of current evidence is low. Further well-designed studies with large sample sizes are warranted to confirm this finding. Nature Publishing Group UK 2021-01-28 /pmc/articles/PMC7843979/ /pubmed/33510347 http://dx.doi.org/10.1038/s41598-021-82351-9 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Yang, Ta-Wei
Lin, Yen-Yue
Hsu, Shih-Chang
Chu, Karen Chia-Wen
Hsiao, Chih-Wei
Hsu, Chin-Wang
Bai, Chyi-Huey
Chang, Cheng-Kuang
Hsu, Yuan-Pin
Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
title Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
title_full Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
title_fullStr Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
title_full_unstemmed Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
title_short Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
title_sort diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7843979/
https://www.ncbi.nlm.nih.gov/pubmed/33510347
http://dx.doi.org/10.1038/s41598-021-82351-9
work_keys_str_mv AT yangtawei diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT linyenyue diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT hsushihchang diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT chukarenchiawen diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT hsiaochihwei diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT hsuchinwang diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT baichyihuey diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT changchengkuang diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis
AT hsuyuanpin diagnosticperformanceofconebeamcomputedtomographyforscaphoidfracturesasystematicreviewanddiagnosticmetaanalysis