Cargando…
Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement
PURPOSE: To compare the safety and efficacy of two different techniques for implantation of the XEN Gel Stent, a minimally invasive surgical device for the treatment of refractory glaucoma. METHODS: A retrospective chart review of eyes that received ab interno or ab externo XEN Gel Stent placement f...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7847364/ https://www.ncbi.nlm.nih.gov/pubmed/33531795 http://dx.doi.org/10.2147/OPTH.S292007 |
_version_ | 1783644917630763008 |
---|---|
author | Tan, Nicholas E Tracer, Nathaniel Terraciano, Anthony Parikh, Hardik A Panarelli, Joseph F Radcliffe, Nathan M |
author_facet | Tan, Nicholas E Tracer, Nathaniel Terraciano, Anthony Parikh, Hardik A Panarelli, Joseph F Radcliffe, Nathan M |
author_sort | Tan, Nicholas E |
collection | PubMed |
description | PURPOSE: To compare the safety and efficacy of two different techniques for implantation of the XEN Gel Stent, a minimally invasive surgical device for the treatment of refractory glaucoma. METHODS: A retrospective chart review of eyes that received ab interno or ab externo XEN Gel Stent placement from February 2017 to October 2019 was conducted. A single surgeon (NMR) performed all operations. Eyes that received the XEN implant concomitant with a glaucoma drainage device insertion or that were lost to 6-month follow-up were excluded. Intraocular pressure (IOP) change, change in glaucoma medications, frequency of slit lamp revision procedures, and frequency of secondary glaucoma surgeries were the primary outcomes compared between groups. RESULTS: Fifty eyes that underwent ab interno placement and 30 eyes that underwent ab externo placement were studied. The ab interno cohort demonstrated a mean IOP reduction of 8.4 ± 1.7 mmHg (28.6% decrease) by 12 months, compared to a mean reduction of 12.8 ± 3.0 mmHg (40.1% decrease) in the ab externo group (p = 0.208). Mean reduction in medication use was 1.81 ± 0.29 medications in the ab interno group and 1.86 ± 0.37 in the ab externo group (p = 0.913). By 12 months, 58% of ab interno eyes had required 5-fluorouracil injection compared to 36.7% of ab externos (p = 0.105). Bleb needling was applied to 42% and 26.7% of the eyes, respectively (p = 0.231). A second glaucoma surgery was necessary for 20% of the ab interno cohort and 10% of the ab externo cohort (p = 0.351). CONCLUSION: There were no differences in outcomes between ab interno and ab externo placement of the XEN Gel Stent. Both approaches are safe and effective for lowering IOP. |
format | Online Article Text |
id | pubmed-7847364 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-78473642021-02-01 Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement Tan, Nicholas E Tracer, Nathaniel Terraciano, Anthony Parikh, Hardik A Panarelli, Joseph F Radcliffe, Nathan M Clin Ophthalmol Original Research PURPOSE: To compare the safety and efficacy of two different techniques for implantation of the XEN Gel Stent, a minimally invasive surgical device for the treatment of refractory glaucoma. METHODS: A retrospective chart review of eyes that received ab interno or ab externo XEN Gel Stent placement from February 2017 to October 2019 was conducted. A single surgeon (NMR) performed all operations. Eyes that received the XEN implant concomitant with a glaucoma drainage device insertion or that were lost to 6-month follow-up were excluded. Intraocular pressure (IOP) change, change in glaucoma medications, frequency of slit lamp revision procedures, and frequency of secondary glaucoma surgeries were the primary outcomes compared between groups. RESULTS: Fifty eyes that underwent ab interno placement and 30 eyes that underwent ab externo placement were studied. The ab interno cohort demonstrated a mean IOP reduction of 8.4 ± 1.7 mmHg (28.6% decrease) by 12 months, compared to a mean reduction of 12.8 ± 3.0 mmHg (40.1% decrease) in the ab externo group (p = 0.208). Mean reduction in medication use was 1.81 ± 0.29 medications in the ab interno group and 1.86 ± 0.37 in the ab externo group (p = 0.913). By 12 months, 58% of ab interno eyes had required 5-fluorouracil injection compared to 36.7% of ab externos (p = 0.105). Bleb needling was applied to 42% and 26.7% of the eyes, respectively (p = 0.231). A second glaucoma surgery was necessary for 20% of the ab interno cohort and 10% of the ab externo cohort (p = 0.351). CONCLUSION: There were no differences in outcomes between ab interno and ab externo placement of the XEN Gel Stent. Both approaches are safe and effective for lowering IOP. Dove 2021-01-26 /pmc/articles/PMC7847364/ /pubmed/33531795 http://dx.doi.org/10.2147/OPTH.S292007 Text en © 2021 Tan et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Tan, Nicholas E Tracer, Nathaniel Terraciano, Anthony Parikh, Hardik A Panarelli, Joseph F Radcliffe, Nathan M Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement |
title | Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement |
title_full | Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement |
title_fullStr | Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement |
title_full_unstemmed | Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement |
title_short | Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement |
title_sort | comparison of safety and efficacy between ab interno and ab externo approaches to xen gel stent placement |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7847364/ https://www.ncbi.nlm.nih.gov/pubmed/33531795 http://dx.doi.org/10.2147/OPTH.S292007 |
work_keys_str_mv | AT tannicholase comparisonofsafetyandefficacybetweenabinternoandabexternoapproachestoxengelstentplacement AT tracernathaniel comparisonofsafetyandefficacybetweenabinternoandabexternoapproachestoxengelstentplacement AT terracianoanthony comparisonofsafetyandefficacybetweenabinternoandabexternoapproachestoxengelstentplacement AT parikhhardika comparisonofsafetyandefficacybetweenabinternoandabexternoapproachestoxengelstentplacement AT panarellijosephf comparisonofsafetyandefficacybetweenabinternoandabexternoapproachestoxengelstentplacement AT radcliffenathanm comparisonofsafetyandefficacybetweenabinternoandabexternoapproachestoxengelstentplacement |