Cargando…

Interobserver and intraobserver reliability for 2 grading systems for gastric ulcer syndrome in horses

BACKGROUND: Grading of equine gastric ulcer syndrome (EGUS) is undertaken in clinical and research settings, but the reliability of EGUS grading systems is poorly understood. HYPOTHESIS/OBJECTIVES: Investigate interobserver and intraobserver reliability of an established ordinal grading system and a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wise, Jessica C., Wilkes, Edwina J.A., Raidal, Sharanne L., Xie, Gang, Crosby, Danielle E., Hale, Josephine N., Hughes, Kristopher J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7848314/
https://www.ncbi.nlm.nih.gov/pubmed/33284465
http://dx.doi.org/10.1111/jvim.15987
Descripción
Sumario:BACKGROUND: Grading of equine gastric ulcer syndrome (EGUS) is undertaken in clinical and research settings, but the reliability of EGUS grading systems is poorly understood. HYPOTHESIS/OBJECTIVES: Investigate interobserver and intraobserver reliability of an established ordinal grading system and a novel visual analog scale (VAS), and assess the influence of observer experience. ANIMALS: Sixty deidentified gastroscopy videos. METHODS: Six observers (3 specialists and 3 residents) graded videos using the EGUS Council (EGUC) system and VAS. Observers graded the videos three 3 for each system, using a cross‐over design with at least 1 week between each phase. The order of videos was randomized for each phase. METHODS: Interobserver and intraobserver reliability were estimated using Gwet's agreement coefficient with ordinal weights applied (AC2) for the EGUC system and the intraclass correlation coefficient (ICC) for the VAS. RESULTS: Using the EGUC system, interobserver reliability was substantial for squamous (AC2 = 0.69; 95% confidence interval [CI], 0.57‐0.80) and glandular mucosa (AC2 = 0.72; 95% CI, 0.70‐0.75), and intraobserver reliability was substantial for squamous (AC2 = 0.80; 95% CI, 0.71‐0.90) and glandular mucosa (AC2 = 0.80; 95% CI, 0.74‐0.86). Interobserver reliability using the VAS was moderate for squamous (ICC = 0.64; 95% CI, 0.31‐0.96) and poor for glandular mucosa (ICC = 0.35; 95% CI, 0.06‐0.64), and intraobserver reliability was moderate for squamous (ICC = 0.74; 95% CI, 0.62‐0.86) and glandular mucosa (ICC = 0.56; 95% CI, 0.39‐0.72). CONCLUSIONS AND CLINICAL IMPORTANCE: The EGUC system had acceptable intraobserver and interobserver reliability and performed well regardless of observer experience. Familiarity and observer experience improved reliability of the VAS.