Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report
RATIONALE: An esophago-bronchial fistula is one of the rare postoperative complications of esophageal cancer. There are various medical treatments, including suturing, endoscopic clip, and fibrin glue. However, these treatments often lead to unsatisfactory results, causing physicians to opt for surg...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7850741/ https://www.ncbi.nlm.nih.gov/pubmed/33530270 http://dx.doi.org/10.1097/MD.0000000000024494 |
_version_ | 1783645501369876480 |
---|---|
author | Sonomura, Jun Shimizu, Tetsunosuke Taniguchi, Kohei Lee, Sang-Woong Tanaka, Ryo Imai, Yoshiro Honda, Kotaro Kawai, Masaru Tashiro, Keitaro Uchiyama, Kazuhisa |
author_facet | Sonomura, Jun Shimizu, Tetsunosuke Taniguchi, Kohei Lee, Sang-Woong Tanaka, Ryo Imai, Yoshiro Honda, Kotaro Kawai, Masaru Tashiro, Keitaro Uchiyama, Kazuhisa |
author_sort | Sonomura, Jun |
collection | PubMed |
description | RATIONALE: An esophago-bronchial fistula is one of the rare postoperative complications of esophageal cancer. There are various medical treatments, including suturing, endoscopic clip, and fibrin glue. However, these treatments often lead to unsatisfactory results, causing physicians to opt for surgical alternatives. The Over-The-Scope-Clipping (OTSC) system offers an alternative method for fistula closure. It can capture a large amount of tissue and is able to compress the lesion until it has fully healed. However, data indicating the efficacy of OTSC for esophago-bronchial fistula are limited. PATIENT CONCERNS: A 64-year-old man presented with an esophago-bronchial fistula after surgery for esophageal cancer. We chose to use a stent as the first line of treatment, but the fistula did not close. DIAGNOSES: Intractable esophago-bronchial fistula associated with esophageal surgery. INTERVENTIONS AND OUTCOMES: On the 94th postoperative day, fistula closure with OTSC was performed, and no leakage of the contrast agent was observed during fluoroscopy. We also attempted to close the fistula by combining OTSC and argon plasma coagulation (APC) to burn off the scar tissue from around the fistula. The fistula gradually shrank after a total of 4 rounds of OTSC, and closure of the fistula was achieved on the 185th postoperative day. There were no adverse events during the treatment of this case. LESSONS: We demonstrate that OTSC is useful in the management of esophago-bronchial fistulas, and may become a standard procedure for the endoscopic treatment of esophago-bronchial fistulas, replacing the use of stents, clips, or glue. |
format | Online Article Text |
id | pubmed-7850741 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-78507412021-02-02 Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report Sonomura, Jun Shimizu, Tetsunosuke Taniguchi, Kohei Lee, Sang-Woong Tanaka, Ryo Imai, Yoshiro Honda, Kotaro Kawai, Masaru Tashiro, Keitaro Uchiyama, Kazuhisa Medicine (Baltimore) 7100 RATIONALE: An esophago-bronchial fistula is one of the rare postoperative complications of esophageal cancer. There are various medical treatments, including suturing, endoscopic clip, and fibrin glue. However, these treatments often lead to unsatisfactory results, causing physicians to opt for surgical alternatives. The Over-The-Scope-Clipping (OTSC) system offers an alternative method for fistula closure. It can capture a large amount of tissue and is able to compress the lesion until it has fully healed. However, data indicating the efficacy of OTSC for esophago-bronchial fistula are limited. PATIENT CONCERNS: A 64-year-old man presented with an esophago-bronchial fistula after surgery for esophageal cancer. We chose to use a stent as the first line of treatment, but the fistula did not close. DIAGNOSES: Intractable esophago-bronchial fistula associated with esophageal surgery. INTERVENTIONS AND OUTCOMES: On the 94th postoperative day, fistula closure with OTSC was performed, and no leakage of the contrast agent was observed during fluoroscopy. We also attempted to close the fistula by combining OTSC and argon plasma coagulation (APC) to burn off the scar tissue from around the fistula. The fistula gradually shrank after a total of 4 rounds of OTSC, and closure of the fistula was achieved on the 185th postoperative day. There were no adverse events during the treatment of this case. LESSONS: We demonstrate that OTSC is useful in the management of esophago-bronchial fistulas, and may become a standard procedure for the endoscopic treatment of esophago-bronchial fistulas, replacing the use of stents, clips, or glue. Lippincott Williams & Wilkins 2021-01-29 /pmc/articles/PMC7850741/ /pubmed/33530270 http://dx.doi.org/10.1097/MD.0000000000024494 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) |
spellingShingle | 7100 Sonomura, Jun Shimizu, Tetsunosuke Taniguchi, Kohei Lee, Sang-Woong Tanaka, Ryo Imai, Yoshiro Honda, Kotaro Kawai, Masaru Tashiro, Keitaro Uchiyama, Kazuhisa Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report |
title | Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report |
title_full | Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report |
title_fullStr | Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report |
title_full_unstemmed | Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report |
title_short | Esophago-bronchial fistula treated by the Over-The-Scope-Clipping (OTSC) system with argon beam electrocoagulation: A case report |
title_sort | esophago-bronchial fistula treated by the over-the-scope-clipping (otsc) system with argon beam electrocoagulation: a case report |
topic | 7100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7850741/ https://www.ncbi.nlm.nih.gov/pubmed/33530270 http://dx.doi.org/10.1097/MD.0000000000024494 |
work_keys_str_mv | AT sonomurajun esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT shimizutetsunosuke esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT taniguchikohei esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT leesangwoong esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT tanakaryo esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT imaiyoshiro esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT hondakotaro esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT kawaimasaru esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT tashirokeitaro esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport AT uchiyamakazuhisa esophagobronchialfistulatreatedbytheoverthescopeclippingotscsystemwithargonbeamelectrocoagulationacasereport |