Cargando…

Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery

BACKGROUND: Contamination of the surgeon during gowning is a possible risk factor for prosthetic joint infection in arthroplasty surgery. Surgical helmets are a common form of personal protective equipment used during this type of surgery. Increasingly, there is a focus on the methods of application...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Laurant, Dewar, David, Lobo, Abhirup
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7850938/
https://www.ncbi.nlm.nih.gov/pubmed/33553543
http://dx.doi.org/10.1016/j.artd.2020.11.013
_version_ 1783645540007804928
author Kang, Laurant
Dewar, David
Lobo, Abhirup
author_facet Kang, Laurant
Dewar, David
Lobo, Abhirup
author_sort Kang, Laurant
collection PubMed
description BACKGROUND: Contamination of the surgeon during gowning is a possible risk factor for prosthetic joint infection in arthroplasty surgery. Surgical helmets are a common form of personal protective equipment used during this type of surgery. Increasingly, there is a focus on the methods of application of the surgical hood and gown while wearing these helmets. METHODS: Ultraviolet fluorescent powder was used to represent air-borne contaminant and applied through the airflow inlet of the surgical helmet. Seven methods of helmet and surgical gown application methods were examined. A ultraviolet torch was used to determine the level of contamination across 11 body regions. A single body region with less than 10 particles was classified as minor contamination, and over 10 particles as major contamination. RESULTS: Early activation of the surgical helmet resulted in significant level of contamination across the majority of body regions. Major contamination also affected the scrub nurse when applying the surgical hood to the surgeon’s helmet. Late activation of helmet system resulted in only minor level of contamination to the surgeon’s shoulders and forearms. Adhesive wrist wraps over the inner gloves did not decrease contamination when added to late activation of the helmet. CONCLUSION: It is our recommendation that the surgical hood should be applied by an unsterile theater assistant and that the surgical helmet system should be activated after the surgeon has applied inner gloves to minimize the level of contamination to the surgeon’s gown.
format Online
Article
Text
id pubmed-7850938
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78509382021-02-05 Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery Kang, Laurant Dewar, David Lobo, Abhirup Arthroplast Today Original Research BACKGROUND: Contamination of the surgeon during gowning is a possible risk factor for prosthetic joint infection in arthroplasty surgery. Surgical helmets are a common form of personal protective equipment used during this type of surgery. Increasingly, there is a focus on the methods of application of the surgical hood and gown while wearing these helmets. METHODS: Ultraviolet fluorescent powder was used to represent air-borne contaminant and applied through the airflow inlet of the surgical helmet. Seven methods of helmet and surgical gown application methods were examined. A ultraviolet torch was used to determine the level of contamination across 11 body regions. A single body region with less than 10 particles was classified as minor contamination, and over 10 particles as major contamination. RESULTS: Early activation of the surgical helmet resulted in significant level of contamination across the majority of body regions. Major contamination also affected the scrub nurse when applying the surgical hood to the surgeon’s helmet. Late activation of helmet system resulted in only minor level of contamination to the surgeon’s shoulders and forearms. Adhesive wrist wraps over the inner gloves did not decrease contamination when added to late activation of the helmet. CONCLUSION: It is our recommendation that the surgical hood should be applied by an unsterile theater assistant and that the surgical helmet system should be activated after the surgeon has applied inner gloves to minimize the level of contamination to the surgeon’s gown. Elsevier 2021-01-30 /pmc/articles/PMC7850938/ /pubmed/33553543 http://dx.doi.org/10.1016/j.artd.2020.11.013 Text en Crown Copyright © 2020 Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Kang, Laurant
Dewar, David
Lobo, Abhirup
Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery
title Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery
title_full Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery
title_fullStr Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery
title_full_unstemmed Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery
title_short Examination of Surgical Helmet and Surgical Hood Application Methods in Reducing Contamination in Arthroplasty Surgery
title_sort examination of surgical helmet and surgical hood application methods in reducing contamination in arthroplasty surgery
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7850938/
https://www.ncbi.nlm.nih.gov/pubmed/33553543
http://dx.doi.org/10.1016/j.artd.2020.11.013
work_keys_str_mv AT kanglaurant examinationofsurgicalhelmetandsurgicalhoodapplicationmethodsinreducingcontaminationinarthroplastysurgery
AT dewardavid examinationofsurgicalhelmetandsurgicalhoodapplicationmethodsinreducingcontaminationinarthroplastysurgery
AT loboabhirup examinationofsurgicalhelmetandsurgicalhoodapplicationmethodsinreducingcontaminationinarthroplastysurgery