Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia

Limited literature exists on complications specific to the all-polyethylene tibial component in distal femoral replacement (DFR). Unlike in primary arthroplasty with polyethylene components, polyethylene granuloma has not been reported in DFR with an all-polyethylene tibia. Here, we report 2 cases o...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, J. Patrick, Nooh, Anas, Tayara, Bader, Jung, Sungmi, Turcotte, Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851358/
https://www.ncbi.nlm.nih.gov/pubmed/33553544
http://dx.doi.org/10.1016/j.artd.2020.12.017
_version_ 1783645609793683456
author Park, J. Patrick
Nooh, Anas
Tayara, Bader
Jung, Sungmi
Turcotte, Robert
author_facet Park, J. Patrick
Nooh, Anas
Tayara, Bader
Jung, Sungmi
Turcotte, Robert
author_sort Park, J. Patrick
collection PubMed
description Limited literature exists on complications specific to the all-polyethylene tibial component in distal femoral replacement (DFR). Unlike in primary arthroplasty with polyethylene components, polyethylene granuloma has not been reported in DFR with an all-polyethylene tibia. Here, we report 2 cases of polyethylene granuloma in patients with primary bone sarcoma who underwent DFR with an all-polyethylene tibia. Radiologically, evidence of intraosseous granuloma formation and periprosthetic osteolysis was observed at the anterior tibial metaphysis. Both patients underwent an operative debridement of polyethylene granuloma and necrotic tissues, followed by a revision to a long-stem, cemented metal-backed tibia with impacted allograft to fill the defect. Polyethylene granuloma should be considered a differential diagnosis in the presence of a periprosthetic lytic lesion after DFR with an all-polyethylene tibial component.
format Online
Article
Text
id pubmed-7851358
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78513582021-02-05 Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia Park, J. Patrick Nooh, Anas Tayara, Bader Jung, Sungmi Turcotte, Robert Arthroplast Today Case Report Limited literature exists on complications specific to the all-polyethylene tibial component in distal femoral replacement (DFR). Unlike in primary arthroplasty with polyethylene components, polyethylene granuloma has not been reported in DFR with an all-polyethylene tibia. Here, we report 2 cases of polyethylene granuloma in patients with primary bone sarcoma who underwent DFR with an all-polyethylene tibia. Radiologically, evidence of intraosseous granuloma formation and periprosthetic osteolysis was observed at the anterior tibial metaphysis. Both patients underwent an operative debridement of polyethylene granuloma and necrotic tissues, followed by a revision to a long-stem, cemented metal-backed tibia with impacted allograft to fill the defect. Polyethylene granuloma should be considered a differential diagnosis in the presence of a periprosthetic lytic lesion after DFR with an all-polyethylene tibial component. Elsevier 2021-01-30 /pmc/articles/PMC7851358/ /pubmed/33553544 http://dx.doi.org/10.1016/j.artd.2020.12.017 Text en © 2021 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Park, J. Patrick
Nooh, Anas
Tayara, Bader
Jung, Sungmi
Turcotte, Robert
Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia
title Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia
title_full Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia
title_fullStr Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia
title_full_unstemmed Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia
title_short Two Cases of Polyethylene Granuloma After Distal Femoral Endoprosthesis With All-Polyethylene Tibia
title_sort two cases of polyethylene granuloma after distal femoral endoprosthesis with all-polyethylene tibia
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851358/
https://www.ncbi.nlm.nih.gov/pubmed/33553544
http://dx.doi.org/10.1016/j.artd.2020.12.017
work_keys_str_mv AT parkjpatrick twocasesofpolyethylenegranulomaafterdistalfemoralendoprosthesiswithallpolyethylenetibia
AT noohanas twocasesofpolyethylenegranulomaafterdistalfemoralendoprosthesiswithallpolyethylenetibia
AT tayarabader twocasesofpolyethylenegranulomaafterdistalfemoralendoprosthesiswithallpolyethylenetibia
AT jungsungmi twocasesofpolyethylenegranulomaafterdistalfemoralendoprosthesiswithallpolyethylenetibia
AT turcotterobert twocasesofpolyethylenegranulomaafterdistalfemoralendoprosthesiswithallpolyethylenetibia