Cargando…

A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report

INTRODUCTION AND IMPORTANCE: The computer-guided approach for the patient-specific TMJ replacement is considered an ultimate reliable option in advanced cases. However, dislocation of the condylar head could happen with the concave fossa design. A flat design was described and used in this case. CAS...

Descripción completa

Detalles Bibliográficos
Autores principales: Shawky, Mohamed, Elbehairy, Mohamed S., Atef, Mohammed, Amr, Khaled
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851359/
https://www.ncbi.nlm.nih.gov/pubmed/33529825
http://dx.doi.org/10.1016/j.ijscr.2021.01.078
_version_ 1783645610024370176
author Shawky, Mohamed
Elbehairy, Mohamed S.
Atef, Mohammed
Amr, Khaled
author_facet Shawky, Mohamed
Elbehairy, Mohamed S.
Atef, Mohammed
Amr, Khaled
author_sort Shawky, Mohamed
collection PubMed
description INTRODUCTION AND IMPORTANCE: The computer-guided approach for the patient-specific TMJ replacement is considered an ultimate reliable option in advanced cases. However, dislocation of the condylar head could happen with the concave fossa design. A flat design was described and used in this case. CASE PRESENTATION: A 15 years old male patient with mandibular asymmetry and class IV recurrent ankylosis of the right TMJ received a patient-specific artificial joint with computer-guided gap arthroplasty and orthognathic corrective mandibular surgery for the left side. The fossa component was made entirely flat, and the patient was followed up over the next year. CLINICAL DISCUSSION: Customized TMJ prosthetic solutions are reliable in advanced cases, especially when facial corrections are indicated; however, the commonly used concave design showed reported dislocations requiring some design modifications as proposed in the presented case. CONCLUSION: The flat fossa design of the artificial TMJ secures the same results as the anatomical fossa design without the incidence of dislocation.
format Online
Article
Text
id pubmed-7851359
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78513592021-02-05 A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report Shawky, Mohamed Elbehairy, Mohamed S. Atef, Mohammed Amr, Khaled Int J Surg Case Rep Case Report INTRODUCTION AND IMPORTANCE: The computer-guided approach for the patient-specific TMJ replacement is considered an ultimate reliable option in advanced cases. However, dislocation of the condylar head could happen with the concave fossa design. A flat design was described and used in this case. CASE PRESENTATION: A 15 years old male patient with mandibular asymmetry and class IV recurrent ankylosis of the right TMJ received a patient-specific artificial joint with computer-guided gap arthroplasty and orthognathic corrective mandibular surgery for the left side. The fossa component was made entirely flat, and the patient was followed up over the next year. CLINICAL DISCUSSION: Customized TMJ prosthetic solutions are reliable in advanced cases, especially when facial corrections are indicated; however, the commonly used concave design showed reported dislocations requiring some design modifications as proposed in the presented case. CONCLUSION: The flat fossa design of the artificial TMJ secures the same results as the anatomical fossa design without the incidence of dislocation. Elsevier 2021-01-22 /pmc/articles/PMC7851359/ /pubmed/33529825 http://dx.doi.org/10.1016/j.ijscr.2021.01.078 Text en © 2021 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Shawky, Mohamed
Elbehairy, Mohamed S.
Atef, Mohammed
Amr, Khaled
A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report
title A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report
title_full A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report
title_fullStr A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report
title_full_unstemmed A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report
title_short A single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: A case report
title_sort single-stage computer-guided gap arthroplasty with simultaneous patient-specific total joint replacement with a novel flat fossa design: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851359/
https://www.ncbi.nlm.nih.gov/pubmed/33529825
http://dx.doi.org/10.1016/j.ijscr.2021.01.078
work_keys_str_mv AT shawkymohamed asinglestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT elbehairymohameds asinglestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT atefmohammed asinglestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT amrkhaled asinglestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT shawkymohamed singlestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT elbehairymohameds singlestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT atefmohammed singlestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport
AT amrkhaled singlestagecomputerguidedgaparthroplastywithsimultaneouspatientspecifictotaljointreplacementwithanovelflatfossadesignacasereport