Cargando…
A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study
BACKGROUND: Traditionally, the technique of modified tension band wires (MTBW) has been the most commonly used surgical procedure. The purpose of this study is to design a precise navigation device that can obtain a standard position of K-wires for (MTBW) and to compare the precise MTBW (P-MTBW) by...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851942/ https://www.ncbi.nlm.nih.gov/pubmed/33526054 http://dx.doi.org/10.1186/s13018-021-02235-6 |
_version_ | 1783645721225854976 |
---|---|
author | Wang, Fuming Xiong, Haolan Long, Xiaotao Li, Yang Chen, Xiaohua Wang, Gang |
author_facet | Wang, Fuming Xiong, Haolan Long, Xiaotao Li, Yang Chen, Xiaohua Wang, Gang |
author_sort | Wang, Fuming |
collection | PubMed |
description | BACKGROUND: Traditionally, the technique of modified tension band wires (MTBW) has been the most commonly used surgical procedure. The purpose of this study is to design a precise navigation device that can obtain a standard position of K-wires for (MTBW) and to compare the precise MTBW (P-MTBW) by a navigation device with the conventional MTBW (C-MTBW) by hands in a retrospective study. METHODS: The device was designed by solidworks2012 software (USA), which could provide a precise guidance for obtaining parallel K-wires. Besides, it could set the distance between two K-wires and the level of K-wires below patellar anterior surface. From June 2014 to August 2018, a total of 112 patients were employed in this retrospective study. The patients were divided into P-MTBW group and C-MTBW group according to the surgical technique with or without the precise navigation device. We needed to record and analyze the operation time and the number of fluoroscopy, postoperative internal fixation imaging, knee function and complications. RESULTS: There were 54 patients in P-MTBW group and 58 patients in C-MTBW group. There were statistically significant differences (P < 0.001) in the operation time between P-MTBW group (39.5 ± 4.7; range, 32–49 min) and C-MTBW group (53.7 ± 6.8; range, 42–71 min). The number of intraoperative fluoroscopy was significantly less (P < 0.001) in P-MTBW group (4.2 ± 1.4) versus that of C-MTBW group (8.3 ± 2.7). According to Iowa knee score, there was no significant difference (P = 0.268 at 1 year) in function between the two groups. According to our own evaluation criteria for MTBW, anyone in the P-MTBW group was excellent and 26 patients were excellent, 20 patients were good, and 2 patients were fair in the C-MTBW group. CONCLUSION: The navigation device can reduce operation time and intraoperative fluoroscopy frequency. P-MTBW fixation is an accurate and effective surgical procedure for patella fractures. |
format | Online Article Text |
id | pubmed-7851942 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-78519422021-02-03 A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study Wang, Fuming Xiong, Haolan Long, Xiaotao Li, Yang Chen, Xiaohua Wang, Gang J Orthop Surg Res Research Article BACKGROUND: Traditionally, the technique of modified tension band wires (MTBW) has been the most commonly used surgical procedure. The purpose of this study is to design a precise navigation device that can obtain a standard position of K-wires for (MTBW) and to compare the precise MTBW (P-MTBW) by a navigation device with the conventional MTBW (C-MTBW) by hands in a retrospective study. METHODS: The device was designed by solidworks2012 software (USA), which could provide a precise guidance for obtaining parallel K-wires. Besides, it could set the distance between two K-wires and the level of K-wires below patellar anterior surface. From June 2014 to August 2018, a total of 112 patients were employed in this retrospective study. The patients were divided into P-MTBW group and C-MTBW group according to the surgical technique with or without the precise navigation device. We needed to record and analyze the operation time and the number of fluoroscopy, postoperative internal fixation imaging, knee function and complications. RESULTS: There were 54 patients in P-MTBW group and 58 patients in C-MTBW group. There were statistically significant differences (P < 0.001) in the operation time between P-MTBW group (39.5 ± 4.7; range, 32–49 min) and C-MTBW group (53.7 ± 6.8; range, 42–71 min). The number of intraoperative fluoroscopy was significantly less (P < 0.001) in P-MTBW group (4.2 ± 1.4) versus that of C-MTBW group (8.3 ± 2.7). According to Iowa knee score, there was no significant difference (P = 0.268 at 1 year) in function between the two groups. According to our own evaluation criteria for MTBW, anyone in the P-MTBW group was excellent and 26 patients were excellent, 20 patients were good, and 2 patients were fair in the C-MTBW group. CONCLUSION: The navigation device can reduce operation time and intraoperative fluoroscopy frequency. P-MTBW fixation is an accurate and effective surgical procedure for patella fractures. BioMed Central 2021-02-01 /pmc/articles/PMC7851942/ /pubmed/33526054 http://dx.doi.org/10.1186/s13018-021-02235-6 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Wang, Fuming Xiong, Haolan Long, Xiaotao Li, Yang Chen, Xiaohua Wang, Gang A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study |
title | A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study |
title_full | A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study |
title_fullStr | A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study |
title_full_unstemmed | A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study |
title_short | A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study |
title_sort | precise navigation device for fixation of patella fractures with modified k-wire tension band:a comparative retrospective study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851942/ https://www.ncbi.nlm.nih.gov/pubmed/33526054 http://dx.doi.org/10.1186/s13018-021-02235-6 |
work_keys_str_mv | AT wangfuming aprecisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT xionghaolan aprecisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT longxiaotao aprecisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT liyang aprecisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT chenxiaohua aprecisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT wanggang aprecisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT wangfuming precisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT xionghaolan precisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT longxiaotao precisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT liyang precisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT chenxiaohua precisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy AT wanggang precisenavigationdeviceforfixationofpatellafractureswithmodifiedkwiretensionbandacomparativeretrospectivestudy |