Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study
BACKGROUND AND AIMS: The piston-pump method is a simple method for rapid administration of fluids but some problems are unsolved. We compared the effectiveness of using the piston-pump method with that of the pressure-infusor method. METHODS: Twelve anaesthetists were classified randomly into the pi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7852453/ https://www.ncbi.nlm.nih.gov/pubmed/33542570 http://dx.doi.org/10.4103/ija.IJA_864_20 |
_version_ | 1783645826536439808 |
---|---|
author | Hashimoto, Wataru Takenaka, Ichiro Yasunami, Keisuke Minami, Tomoko Sano, Haruhiko |
author_facet | Hashimoto, Wataru Takenaka, Ichiro Yasunami, Keisuke Minami, Tomoko Sano, Haruhiko |
author_sort | Hashimoto, Wataru |
collection | PubMed |
description | BACKGROUND AND AIMS: The piston-pump method is a simple method for rapid administration of fluids but some problems are unsolved. We compared the effectiveness of using the piston-pump method with that of the pressure-infusor method. METHODS: Twelve anaesthetists were classified randomly into the piston-pump and pressure-infusor groups. They were asked to infuse 500 ml of saline three times successively through a 16-G intravenous cannula as rapidly as possible using a pump with a 50-ml syringe or a pressure-infusor at 300 mmHg. The time taken for infusion and the maximum or minimum pressure in the infusion circuit and substitute vessel were measured. Bacterial culture of the saline infused sterilely was performed to estimate bacterial contamination. RESULTS: The pressure-infusor group led to faster infusion of 500 ml of saline (233 ± 19 s) than the piston-pump group (301 ± 48 s) (P < 0.01). The infusion time at the third attempt (316 ± 43 s) was significantly longer than that at the first attempt (285 ± 53 s) only in the piston-pump group (P < 0.05). The maximum pressure (mmHg) in the circuit was 131 ± 9 and > 200 (P < 0.01) and in the substitute vessel was 5 ± 1 and 17 ± 7 (P < 0.01) in the pressure-infusor and piston-pump groups, respectively. A pressure of <-200 mmHg occurred at all infusion attempts in the piston-pump group. Bacterial contamination was not observed in either group. CONCLUSION: If fluids must be administered rapidly, the pressure-infusor method is more efficient than the piston-pump method because the latter is less effective in infusing fluids rapidly and associated with excessive positive and negative pressure in the infusion circuit. |
format | Online Article Text |
id | pubmed-7852453 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-78524532021-02-03 Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study Hashimoto, Wataru Takenaka, Ichiro Yasunami, Keisuke Minami, Tomoko Sano, Haruhiko Indian J Anaesth Original Article BACKGROUND AND AIMS: The piston-pump method is a simple method for rapid administration of fluids but some problems are unsolved. We compared the effectiveness of using the piston-pump method with that of the pressure-infusor method. METHODS: Twelve anaesthetists were classified randomly into the piston-pump and pressure-infusor groups. They were asked to infuse 500 ml of saline three times successively through a 16-G intravenous cannula as rapidly as possible using a pump with a 50-ml syringe or a pressure-infusor at 300 mmHg. The time taken for infusion and the maximum or minimum pressure in the infusion circuit and substitute vessel were measured. Bacterial culture of the saline infused sterilely was performed to estimate bacterial contamination. RESULTS: The pressure-infusor group led to faster infusion of 500 ml of saline (233 ± 19 s) than the piston-pump group (301 ± 48 s) (P < 0.01). The infusion time at the third attempt (316 ± 43 s) was significantly longer than that at the first attempt (285 ± 53 s) only in the piston-pump group (P < 0.05). The maximum pressure (mmHg) in the circuit was 131 ± 9 and > 200 (P < 0.01) and in the substitute vessel was 5 ± 1 and 17 ± 7 (P < 0.01) in the pressure-infusor and piston-pump groups, respectively. A pressure of <-200 mmHg occurred at all infusion attempts in the piston-pump group. Bacterial contamination was not observed in either group. CONCLUSION: If fluids must be administered rapidly, the pressure-infusor method is more efficient than the piston-pump method because the latter is less effective in infusing fluids rapidly and associated with excessive positive and negative pressure in the infusion circuit. Wolters Kluwer - Medknow 2020-12 2020-12-12 /pmc/articles/PMC7852453/ /pubmed/33542570 http://dx.doi.org/10.4103/ija.IJA_864_20 Text en Copyright: © 2020 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Hashimoto, Wataru Takenaka, Ichiro Yasunami, Keisuke Minami, Tomoko Sano, Haruhiko Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study |
title | Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study |
title_full | Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study |
title_fullStr | Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study |
title_full_unstemmed | Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study |
title_short | Comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: A bench study |
title_sort | comparison of effectiveness of the piston-pump method versus the pressure-infusor method for rapid infusion of crystalloids: a bench study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7852453/ https://www.ncbi.nlm.nih.gov/pubmed/33542570 http://dx.doi.org/10.4103/ija.IJA_864_20 |
work_keys_str_mv | AT hashimotowataru comparisonofeffectivenessofthepistonpumpmethodversusthepressureinfusormethodforrapidinfusionofcrystalloidsabenchstudy AT takenakaichiro comparisonofeffectivenessofthepistonpumpmethodversusthepressureinfusormethodforrapidinfusionofcrystalloidsabenchstudy AT yasunamikeisuke comparisonofeffectivenessofthepistonpumpmethodversusthepressureinfusormethodforrapidinfusionofcrystalloidsabenchstudy AT minamitomoko comparisonofeffectivenessofthepistonpumpmethodversusthepressureinfusormethodforrapidinfusionofcrystalloidsabenchstudy AT sanoharuhiko comparisonofeffectivenessofthepistonpumpmethodversusthepressureinfusormethodforrapidinfusionofcrystalloidsabenchstudy |