Cargando…

Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling

BACKGROUND & OBJECTIVES: Public health and diagnostic laboratories are facing huge sample loads for COVID-19 diagnosis by real-time reverse transcription-polymerase chain reaction (RT-PCR). High sensitivity of optimized real-time RT-PCR assays makes pooled testing a potentially efficient strateg...

Descripción completa

Detalles Bibliográficos
Autores principales: Praharaj, Ira, Jain, Amita, Singh, Mini, Balakrishnan, Anukumar, Dhodapkar, Rahul, Borkakoty, Biswajyoti, Ashok, Munivenkatappa, Das, Pradeep, Biswas, Debasis, Kalawat, Usha, Turuk, Jyotirmayee, Sugunan, A.P., Prakash, Shantanu, Singh, Anirudh K., Barathidasan, Rajamani, Subhadra, Subhra, Sabat, Jyotsnamayee, Manjunath, M.J., Kanta, Poonam, Mudhigeti, Nagaraja, Hazarika, Rahul, Mishra, Hricha, Abhishek, Kumar, Santhalembi, C., Dikhit, Manas Ranjan, Vijay, Neetu, Narayan, Jitendra, Kaur, Harmanmeet, Giri, Sidhartha, Gupta, Nivedita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853252/
https://www.ncbi.nlm.nih.gov/pubmed/32893844
http://dx.doi.org/10.4103/ijmr.IJMR_2304_20
_version_ 1783645922160279552
author Praharaj, Ira
Jain, Amita
Singh, Mini
Balakrishnan, Anukumar
Dhodapkar, Rahul
Borkakoty, Biswajyoti
Ashok, Munivenkatappa
Das, Pradeep
Biswas, Debasis
Kalawat, Usha
Turuk, Jyotirmayee
Sugunan, A.P.
Prakash, Shantanu
Singh, Anirudh K.
Barathidasan, Rajamani
Subhadra, Subhra
Sabat, Jyotsnamayee
Manjunath, M.J.
Kanta, Poonam
Mudhigeti, Nagaraja
Hazarika, Rahul
Mishra, Hricha
Abhishek, Kumar
Santhalembi, C.
Dikhit, Manas Ranjan
Vijay, Neetu
Narayan, Jitendra
Kaur, Harmanmeet
Giri, Sidhartha
Gupta, Nivedita
author_facet Praharaj, Ira
Jain, Amita
Singh, Mini
Balakrishnan, Anukumar
Dhodapkar, Rahul
Borkakoty, Biswajyoti
Ashok, Munivenkatappa
Das, Pradeep
Biswas, Debasis
Kalawat, Usha
Turuk, Jyotirmayee
Sugunan, A.P.
Prakash, Shantanu
Singh, Anirudh K.
Barathidasan, Rajamani
Subhadra, Subhra
Sabat, Jyotsnamayee
Manjunath, M.J.
Kanta, Poonam
Mudhigeti, Nagaraja
Hazarika, Rahul
Mishra, Hricha
Abhishek, Kumar
Santhalembi, C.
Dikhit, Manas Ranjan
Vijay, Neetu
Narayan, Jitendra
Kaur, Harmanmeet
Giri, Sidhartha
Gupta, Nivedita
author_sort Praharaj, Ira
collection PubMed
description BACKGROUND & OBJECTIVES: Public health and diagnostic laboratories are facing huge sample loads for COVID-19 diagnosis by real-time reverse transcription-polymerase chain reaction (RT-PCR). High sensitivity of optimized real-time RT-PCR assays makes pooled testing a potentially efficient strategy for resource utilization when positivity rates for particular regions or groups of individuals are low. We report here a comparative analysis of pooled testing for 5- and 10-sample pools by real-time RT-PCR across 10 COVID-19 testing laboratories in India. METHODS: Ten virus research and diagnostic laboratories (VRDLs) testing for COVID-19 by real-time RT-PCR participated in this evaluation. At each laboratory, 100 nasopharyngeal swab samples including 10 positive samples were used to create 5- and 10-sample pools with one positive sample in each pool. RNA extraction and real-time RT-PCR for SARS-CoV-2-specific E gene target were performed for individual positive samples as well as pooled samples. Concordance between individual sample testing and testing in the 5- or 10-sample pools was calculated, and the variation across sites and by sample cycle threshold (C(t)) values was analyzed. RESULTS: A total of 110 each of 5- and 10-sample pools were evaluated. Concordance between the 5-sample pool and individual sample testing was 100 per cent in the C(t) value ≤30 cycles and 95.5 per cent for C(t) values ≤33 cycles. Overall concordance between the 5-sample pooled and individual sample testing was 88 per cent while that between 10-sample pool and individual sample testing was 66 per cent. Although the concordance rates for both the 5- and 10-sample pooled testing varied across laboratories, yet for samples with C(t) values ≤33 cycles, the concordance was ≥90 per cent across all laboratories for the 5-sample pools. INTERPRETATION & CONCLUSIONS: Results from this multi-site assessment suggest that pooling five samples for SARS-CoV-2 detection by real-time RT-PCR may be an acceptable strategy without much loss of sensitivity even for low viral loads, while with 10-sample pools, there may be considerably higher numbers of false negatives. However, testing laboratories should perform validations with the specific RNA extraction and RT-PCR kits in use at their centres before initiating pooled testing.
format Online
Article
Text
id pubmed-7853252
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-78532522021-02-04 Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling Praharaj, Ira Jain, Amita Singh, Mini Balakrishnan, Anukumar Dhodapkar, Rahul Borkakoty, Biswajyoti Ashok, Munivenkatappa Das, Pradeep Biswas, Debasis Kalawat, Usha Turuk, Jyotirmayee Sugunan, A.P. Prakash, Shantanu Singh, Anirudh K. Barathidasan, Rajamani Subhadra, Subhra Sabat, Jyotsnamayee Manjunath, M.J. Kanta, Poonam Mudhigeti, Nagaraja Hazarika, Rahul Mishra, Hricha Abhishek, Kumar Santhalembi, C. Dikhit, Manas Ranjan Vijay, Neetu Narayan, Jitendra Kaur, Harmanmeet Giri, Sidhartha Gupta, Nivedita Indian J Med Res Original Article BACKGROUND & OBJECTIVES: Public health and diagnostic laboratories are facing huge sample loads for COVID-19 diagnosis by real-time reverse transcription-polymerase chain reaction (RT-PCR). High sensitivity of optimized real-time RT-PCR assays makes pooled testing a potentially efficient strategy for resource utilization when positivity rates for particular regions or groups of individuals are low. We report here a comparative analysis of pooled testing for 5- and 10-sample pools by real-time RT-PCR across 10 COVID-19 testing laboratories in India. METHODS: Ten virus research and diagnostic laboratories (VRDLs) testing for COVID-19 by real-time RT-PCR participated in this evaluation. At each laboratory, 100 nasopharyngeal swab samples including 10 positive samples were used to create 5- and 10-sample pools with one positive sample in each pool. RNA extraction and real-time RT-PCR for SARS-CoV-2-specific E gene target were performed for individual positive samples as well as pooled samples. Concordance between individual sample testing and testing in the 5- or 10-sample pools was calculated, and the variation across sites and by sample cycle threshold (C(t)) values was analyzed. RESULTS: A total of 110 each of 5- and 10-sample pools were evaluated. Concordance between the 5-sample pool and individual sample testing was 100 per cent in the C(t) value ≤30 cycles and 95.5 per cent for C(t) values ≤33 cycles. Overall concordance between the 5-sample pooled and individual sample testing was 88 per cent while that between 10-sample pool and individual sample testing was 66 per cent. Although the concordance rates for both the 5- and 10-sample pooled testing varied across laboratories, yet for samples with C(t) values ≤33 cycles, the concordance was ≥90 per cent across all laboratories for the 5-sample pools. INTERPRETATION & CONCLUSIONS: Results from this multi-site assessment suggest that pooling five samples for SARS-CoV-2 detection by real-time RT-PCR may be an acceptable strategy without much loss of sensitivity even for low viral loads, while with 10-sample pools, there may be considerably higher numbers of false negatives. However, testing laboratories should perform validations with the specific RNA extraction and RT-PCR kits in use at their centres before initiating pooled testing. Wolters Kluwer - Medknow 2020 /pmc/articles/PMC7853252/ /pubmed/32893844 http://dx.doi.org/10.4103/ijmr.IJMR_2304_20 Text en Copyright: © 2020 Indian Journal of Medical Research http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Praharaj, Ira
Jain, Amita
Singh, Mini
Balakrishnan, Anukumar
Dhodapkar, Rahul
Borkakoty, Biswajyoti
Ashok, Munivenkatappa
Das, Pradeep
Biswas, Debasis
Kalawat, Usha
Turuk, Jyotirmayee
Sugunan, A.P.
Prakash, Shantanu
Singh, Anirudh K.
Barathidasan, Rajamani
Subhadra, Subhra
Sabat, Jyotsnamayee
Manjunath, M.J.
Kanta, Poonam
Mudhigeti, Nagaraja
Hazarika, Rahul
Mishra, Hricha
Abhishek, Kumar
Santhalembi, C.
Dikhit, Manas Ranjan
Vijay, Neetu
Narayan, Jitendra
Kaur, Harmanmeet
Giri, Sidhartha
Gupta, Nivedita
Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling
title Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling
title_full Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling
title_fullStr Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling
title_full_unstemmed Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling
title_short Pooled testing for COVID-19 diagnosis by real-time RT-PCR: A multi-site comparative evaluation of 5- & 10-sample pooling
title_sort pooled testing for covid-19 diagnosis by real-time rt-pcr: a multi-site comparative evaluation of 5- & 10-sample pooling
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853252/
https://www.ncbi.nlm.nih.gov/pubmed/32893844
http://dx.doi.org/10.4103/ijmr.IJMR_2304_20
work_keys_str_mv AT praharajira pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT jainamita pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT singhmini pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT balakrishnananukumar pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT dhodapkarrahul pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT borkakotybiswajyoti pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT ashokmunivenkatappa pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT daspradeep pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT biswasdebasis pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT kalawatusha pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT turukjyotirmayee pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT sugunanap pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT prakashshantanu pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT singhanirudhk pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT barathidasanrajamani pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT subhadrasubhra pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT sabatjyotsnamayee pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT manjunathmj pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT kantapoonam pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT mudhigetinagaraja pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT hazarikarahul pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT mishrahricha pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT abhishekkumar pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT santhalembic pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT dikhitmanasranjan pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT vijayneetu pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT narayanjitendra pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT kaurharmanmeet pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT girisidhartha pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling
AT guptanivedita pooledtestingforcovid19diagnosisbyrealtimertpcramultisitecomparativeevaluationof510samplepooling