Cargando…

Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device

OBJECTIVE: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. DESIGN: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly...

Descripción completa

Detalles Bibliográficos
Autores principales: Lodge, Clare, Tobin, Diarmuid, O’Rourke, Brian, Thorborg, Kristian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853328/
https://www.ncbi.nlm.nih.gov/pubmed/33543063
http://dx.doi.org/10.1016/j.arrct.2019.100034
_version_ 1783645937719050240
author Lodge, Clare
Tobin, Diarmuid
O’Rourke, Brian
Thorborg, Kristian
author_facet Lodge, Clare
Tobin, Diarmuid
O’Rourke, Brian
Thorborg, Kristian
author_sort Lodge, Clare
collection PubMed
description OBJECTIVE: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. DESIGN: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device. SETTING: Institute of Technology Carlow, third level educational institution. PARTICIPANTS: Male intercollegiate field-sport players completed the trial (N=19). Participants were 21±2 years, weighed 78.6±4.6 kg, and were 179.6±6.4 cm in height. INTERVENTIONS: N/A. MAIN OUTCOME MEASURES: Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device. RESULTS: High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)=.910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC%=14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively. CONCLUSION(S): The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management.
format Online
Article
Text
id pubmed-7853328
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78533282021-02-03 Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device Lodge, Clare Tobin, Diarmuid O’Rourke, Brian Thorborg, Kristian Arch Rehabil Res Clin Transl Original Research OBJECTIVE: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. DESIGN: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device. SETTING: Institute of Technology Carlow, third level educational institution. PARTICIPANTS: Male intercollegiate field-sport players completed the trial (N=19). Participants were 21±2 years, weighed 78.6±4.6 kg, and were 179.6±6.4 cm in height. INTERVENTIONS: N/A. MAIN OUTCOME MEASURES: Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device. RESULTS: High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)=.910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC%=14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively. CONCLUSION(S): The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management. Elsevier 2019-11-22 /pmc/articles/PMC7853328/ /pubmed/33543063 http://dx.doi.org/10.1016/j.arrct.2019.100034 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Lodge, Clare
Tobin, Diarmuid
O’Rourke, Brian
Thorborg, Kristian
Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
title Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
title_full Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
title_fullStr Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
title_full_unstemmed Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
title_short Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
title_sort reliability and validity of a new eccentric hamstring strength measurement device
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853328/
https://www.ncbi.nlm.nih.gov/pubmed/33543063
http://dx.doi.org/10.1016/j.arrct.2019.100034
work_keys_str_mv AT lodgeclare reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice
AT tobindiarmuid reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice
AT orourkebrian reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice
AT thorborgkristian reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice