Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
OBJECTIVE: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. DESIGN: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853328/ https://www.ncbi.nlm.nih.gov/pubmed/33543063 http://dx.doi.org/10.1016/j.arrct.2019.100034 |
_version_ | 1783645937719050240 |
---|---|
author | Lodge, Clare Tobin, Diarmuid O’Rourke, Brian Thorborg, Kristian |
author_facet | Lodge, Clare Tobin, Diarmuid O’Rourke, Brian Thorborg, Kristian |
author_sort | Lodge, Clare |
collection | PubMed |
description | OBJECTIVE: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. DESIGN: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device. SETTING: Institute of Technology Carlow, third level educational institution. PARTICIPANTS: Male intercollegiate field-sport players completed the trial (N=19). Participants were 21±2 years, weighed 78.6±4.6 kg, and were 179.6±6.4 cm in height. INTERVENTIONS: N/A. MAIN OUTCOME MEASURES: Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device. RESULTS: High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)=.910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC%=14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively. CONCLUSION(S): The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management. |
format | Online Article Text |
id | pubmed-7853328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-78533282021-02-03 Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device Lodge, Clare Tobin, Diarmuid O’Rourke, Brian Thorborg, Kristian Arch Rehabil Res Clin Transl Original Research OBJECTIVE: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. DESIGN: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device. SETTING: Institute of Technology Carlow, third level educational institution. PARTICIPANTS: Male intercollegiate field-sport players completed the trial (N=19). Participants were 21±2 years, weighed 78.6±4.6 kg, and were 179.6±6.4 cm in height. INTERVENTIONS: N/A. MAIN OUTCOME MEASURES: Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device. RESULTS: High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)=.910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC%=14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively. CONCLUSION(S): The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management. Elsevier 2019-11-22 /pmc/articles/PMC7853328/ /pubmed/33543063 http://dx.doi.org/10.1016/j.arrct.2019.100034 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Lodge, Clare Tobin, Diarmuid O’Rourke, Brian Thorborg, Kristian Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device |
title | Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device |
title_full | Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device |
title_fullStr | Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device |
title_full_unstemmed | Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device |
title_short | Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device |
title_sort | reliability and validity of a new eccentric hamstring strength measurement device |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853328/ https://www.ncbi.nlm.nih.gov/pubmed/33543063 http://dx.doi.org/10.1016/j.arrct.2019.100034 |
work_keys_str_mv | AT lodgeclare reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice AT tobindiarmuid reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice AT orourkebrian reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice AT thorborgkristian reliabilityandvalidityofaneweccentrichamstringstrengthmeasurementdevice |