Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room

PURPOSE: Musculoskeletal pain issues are prevalent in ophthalmic surgeons and can impact surgeon well-being and productivity. Heads-up displays (HUD) can improve upon conventional microscopes by reducing ergonomic stress. This study compared ergonomic outcomes between HUD and a conventional optical...

Descripción completa

Detalles Bibliográficos
Autores principales: Weinstock, Robert J, Ainslie-Garcia, Margaret H, Ferko, Nicole C, Qadeer, Rana A, Morris, Leighton P, Cheng, Hang, Ehlers, Justis P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7854362/
https://www.ncbi.nlm.nih.gov/pubmed/33542618
http://dx.doi.org/10.2147/OPTH.S292152
_version_ 1783646072865816576
author Weinstock, Robert J
Ainslie-Garcia, Margaret H
Ferko, Nicole C
Qadeer, Rana A
Morris, Leighton P
Cheng, Hang
Ehlers, Justis P
author_facet Weinstock, Robert J
Ainslie-Garcia, Margaret H
Ferko, Nicole C
Qadeer, Rana A
Morris, Leighton P
Cheng, Hang
Ehlers, Justis P
author_sort Weinstock, Robert J
collection PubMed
description PURPOSE: Musculoskeletal pain issues are prevalent in ophthalmic surgeons and can impact surgeon well-being and productivity. Heads-up displays (HUD) can improve upon conventional microscopes by reducing ergonomic stress. This study compared ergonomic outcomes between HUD and a conventional optical microscope in the operating room, as reported by ophthalmic surgeons in the US. METHODS: An online questionnaire was distributed to a sample of surgeons who had experience operating with HUD. The questionnaire captured surgeon-specific variables, the validated Nordic Musculoskeletal Questionnaire, and custom questions to compare HUD and conventional microscope. A multivariable model was built to identify variables that were likely to predict improvement in pain-related issues. RESULTS: Analysis was conducted on 64 surgeons (37 posterior-segment, 25 anterior-segment, and two mixed) with a mean 14.9 years of practice and 2.3 years using HUD. Most surgeons agreed or strongly agreed that HUD reduced the severity (64%) and frequency (63%) of pain and discomfort, improved posture (73%), and improved overall comfort (77%). Of respondents who experienced headaches, or pain and discomfort during operation, 12 (44%) reported their headaches improved and 45 (82%) reported feeling less pain and discomfort since they started using HUD. The multivariable model indicated the odds of reporting an improvement in pain since introducing the HUD in the operating room were 5.12-times greater for those who used HUD in >50% of their cases (P=0.029). CONCLUSION: This study indicates that heads-up display may be an important tool for wellness in the operating room as it can benefit ophthalmic surgeons across several ergonomic measures.
format Online
Article
Text
id pubmed-7854362
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-78543622021-02-03 Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room Weinstock, Robert J Ainslie-Garcia, Margaret H Ferko, Nicole C Qadeer, Rana A Morris, Leighton P Cheng, Hang Ehlers, Justis P Clin Ophthalmol Original Research PURPOSE: Musculoskeletal pain issues are prevalent in ophthalmic surgeons and can impact surgeon well-being and productivity. Heads-up displays (HUD) can improve upon conventional microscopes by reducing ergonomic stress. This study compared ergonomic outcomes between HUD and a conventional optical microscope in the operating room, as reported by ophthalmic surgeons in the US. METHODS: An online questionnaire was distributed to a sample of surgeons who had experience operating with HUD. The questionnaire captured surgeon-specific variables, the validated Nordic Musculoskeletal Questionnaire, and custom questions to compare HUD and conventional microscope. A multivariable model was built to identify variables that were likely to predict improvement in pain-related issues. RESULTS: Analysis was conducted on 64 surgeons (37 posterior-segment, 25 anterior-segment, and two mixed) with a mean 14.9 years of practice and 2.3 years using HUD. Most surgeons agreed or strongly agreed that HUD reduced the severity (64%) and frequency (63%) of pain and discomfort, improved posture (73%), and improved overall comfort (77%). Of respondents who experienced headaches, or pain and discomfort during operation, 12 (44%) reported their headaches improved and 45 (82%) reported feeling less pain and discomfort since they started using HUD. The multivariable model indicated the odds of reporting an improvement in pain since introducing the HUD in the operating room were 5.12-times greater for those who used HUD in >50% of their cases (P=0.029). CONCLUSION: This study indicates that heads-up display may be an important tool for wellness in the operating room as it can benefit ophthalmic surgeons across several ergonomic measures. Dove 2021-01-29 /pmc/articles/PMC7854362/ /pubmed/33542618 http://dx.doi.org/10.2147/OPTH.S292152 Text en © 2021 Weinstock et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Weinstock, Robert J
Ainslie-Garcia, Margaret H
Ferko, Nicole C
Qadeer, Rana A
Morris, Leighton P
Cheng, Hang
Ehlers, Justis P
Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
title Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
title_full Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
title_fullStr Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
title_full_unstemmed Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
title_short Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
title_sort comparative assessment of ergonomic experience with heads-up display and conventional surgical microscope in the operating room
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7854362/
https://www.ncbi.nlm.nih.gov/pubmed/33542618
http://dx.doi.org/10.2147/OPTH.S292152
work_keys_str_mv AT weinstockrobertj comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom
AT ainsliegarciamargareth comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom
AT ferkonicolec comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom
AT qadeerranaa comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom
AT morrisleightonp comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom
AT chenghang comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom
AT ehlersjustisp comparativeassessmentofergonomicexperiencewithheadsupdisplayandconventionalsurgicalmicroscopeintheoperatingroom