Cargando…
Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty
INTRODUCTION: Surgical site infiltration with bupivacaine HCl results in short-lived analgesia for postsurgical pain and carries the risk of systemic bupivacaine toxicity due to accidental intravascular injection. INL-001 is a bupivacaine HCl collagen-matrix implant that provides extended delivery o...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Healthcare
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7854444/ https://www.ncbi.nlm.nih.gov/pubmed/33237534 http://dx.doi.org/10.1007/s12325-020-01565-x |
_version_ | 1783646090072948736 |
---|---|
author | Leiman, David Niebler, Gwendolyn Minkowitz, Harold S. |
author_facet | Leiman, David Niebler, Gwendolyn Minkowitz, Harold S. |
author_sort | Leiman, David |
collection | PubMed |
description | INTRODUCTION: Surgical site infiltration with bupivacaine HCl results in short-lived analgesia for postsurgical pain and carries the risk of systemic bupivacaine toxicity due to accidental intravascular injection. INL-001 is a bupivacaine HCl collagen-matrix implant that provides extended delivery of bupivacaine directly at the site and avoids the risk of accidental injection. Here, we examine the pharmacokinetic (PK) and safety profile of INL-001 placement during unilateral open inguinal hernioplasty. METHODS: This multicenter, single-blind study (NCT03234374) enrolled patients undergoing open inguinal hernioplasty to receive three INL-001 implants, each containing 100 mg bupivacaine HCl (n = 34) or local infiltration of 0.25% bupivacaine HCl 175 mg (n = 16). Acetaminophen was provided in the postsurgical period and supplemented by opioids for breakthrough pain, as needed. PK blood samples were taken before surgery and up to 96 h after drug administration. RESULTS: INL-001 demonstrated a prolonged rate of absorption and clearance of bupivacaine compared with 0.25% bupivacaine HCl 175 mg, as demonstrated by a longer time to peak plasma concentration and terminal elimination half-life. Peak plasma concentration with INL-001 300 mg was comparable to bupivacaine HCl 175 mg and well below levels associated with systemic bupivacaine toxicity. The most common adverse events (AEs) in both groups were associated with general anesthesia and the postsurgical setting. No AE was related to the implant, including those associated with wound healing. CONCLUSIONS: These findings demonstrate that INL-001 provides immediate and extended delivery of bupivacaine and is well tolerated in patients undergoing open inguinal hernioplasty with no adverse effect on wound healing. TRIAL REGISTRATION: Clinicaltrials.gov identifier, NCT03234374. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12325-020-01565-x) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-7854444 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-78544442021-02-08 Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty Leiman, David Niebler, Gwendolyn Minkowitz, Harold S. Adv Ther Original Research INTRODUCTION: Surgical site infiltration with bupivacaine HCl results in short-lived analgesia for postsurgical pain and carries the risk of systemic bupivacaine toxicity due to accidental intravascular injection. INL-001 is a bupivacaine HCl collagen-matrix implant that provides extended delivery of bupivacaine directly at the site and avoids the risk of accidental injection. Here, we examine the pharmacokinetic (PK) and safety profile of INL-001 placement during unilateral open inguinal hernioplasty. METHODS: This multicenter, single-blind study (NCT03234374) enrolled patients undergoing open inguinal hernioplasty to receive three INL-001 implants, each containing 100 mg bupivacaine HCl (n = 34) or local infiltration of 0.25% bupivacaine HCl 175 mg (n = 16). Acetaminophen was provided in the postsurgical period and supplemented by opioids for breakthrough pain, as needed. PK blood samples were taken before surgery and up to 96 h after drug administration. RESULTS: INL-001 demonstrated a prolonged rate of absorption and clearance of bupivacaine compared with 0.25% bupivacaine HCl 175 mg, as demonstrated by a longer time to peak plasma concentration and terminal elimination half-life. Peak plasma concentration with INL-001 300 mg was comparable to bupivacaine HCl 175 mg and well below levels associated with systemic bupivacaine toxicity. The most common adverse events (AEs) in both groups were associated with general anesthesia and the postsurgical setting. No AE was related to the implant, including those associated with wound healing. CONCLUSIONS: These findings demonstrate that INL-001 provides immediate and extended delivery of bupivacaine and is well tolerated in patients undergoing open inguinal hernioplasty with no adverse effect on wound healing. TRIAL REGISTRATION: Clinicaltrials.gov identifier, NCT03234374. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12325-020-01565-x) contains supplementary material, which is available to authorized users. Springer Healthcare 2020-11-25 2021 /pmc/articles/PMC7854444/ /pubmed/33237534 http://dx.doi.org/10.1007/s12325-020-01565-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Original Research Leiman, David Niebler, Gwendolyn Minkowitz, Harold S. Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty |
title | Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty |
title_full | Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty |
title_fullStr | Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty |
title_full_unstemmed | Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty |
title_short | Pharmacokinetics and Safety of INL-001 (Bupivacaine HCl) Implants Compared with Bupivacaine HCl Infiltration After Open Unilateral Inguinal Hernioplasty |
title_sort | pharmacokinetics and safety of inl-001 (bupivacaine hcl) implants compared with bupivacaine hcl infiltration after open unilateral inguinal hernioplasty |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7854444/ https://www.ncbi.nlm.nih.gov/pubmed/33237534 http://dx.doi.org/10.1007/s12325-020-01565-x |
work_keys_str_mv | AT leimandavid pharmacokineticsandsafetyofinl001bupivacainehclimplantscomparedwithbupivacainehclinfiltrationafteropenunilateralinguinalhernioplasty AT nieblergwendolyn pharmacokineticsandsafetyofinl001bupivacainehclimplantscomparedwithbupivacainehclinfiltrationafteropenunilateralinguinalhernioplasty AT minkowitzharolds pharmacokineticsandsafetyofinl001bupivacainehclimplantscomparedwithbupivacainehclinfiltrationafteropenunilateralinguinalhernioplasty |