Cargando…

Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants

A non-ionic hydrophobic natural deep eutectic solvent (HNADES) based on thymol and menthol was proposed for the liquid-liquid microextraction of fourteen phthalates and one adipate from environmental water samples. Separation, identification, and quantification were achieved by ultra-high-performanc...

Descripción completa

Detalles Bibliográficos
Autores principales: Santana-Mayor, Álvaro, Socas-Rodríguez, Bárbara, Rodríguez-Ramos, Ruth, Herrera-Herrera, Antonio V., Rodríguez-Delgado, Miguel Ángel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856334/
https://www.ncbi.nlm.nih.gov/pubmed/33534021
http://dx.doi.org/10.1007/s00216-021-03166-1
_version_ 1783646231622320128
author Santana-Mayor, Álvaro
Socas-Rodríguez, Bárbara
Rodríguez-Ramos, Ruth
Herrera-Herrera, Antonio V.
Rodríguez-Delgado, Miguel Ángel
author_facet Santana-Mayor, Álvaro
Socas-Rodríguez, Bárbara
Rodríguez-Ramos, Ruth
Herrera-Herrera, Antonio V.
Rodríguez-Delgado, Miguel Ángel
author_sort Santana-Mayor, Álvaro
collection PubMed
description A non-ionic hydrophobic natural deep eutectic solvent (HNADES) based on thymol and menthol was proposed for the liquid-liquid microextraction of fourteen phthalates and one adipate from environmental water samples. Separation, identification, and quantification were achieved by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry. The main factors affecting the extraction efficiency were thoroughly studied. Sample pH of 8 and 100 μL of thymol:menthol at molar ratio 2:1 were selected as the best conditions, while ionic strength and type of dispersant solvent were not relevant for the extraction of the target compounds. The whole methodology was validated for treated wastewater, runoff, and pond water matrices, using di-n-butyl phthalate-3,4,5,6-d(4) and dihexyl phthalate-3,4,5,6-d(4) as surrogates. Recovery ranged from 70 to 127% with relative standard deviation values lower than 14%. Limits of quantification of the method were in the range 0.042–0.425 μg/L for treated wastewater, 0.015–0.386 μg/L for runoff, and 0.013–0.376 μg/L for pond water. The methodology was applied for the analysis of real treated wastewater, runoff, and pond water samples from different places of Tenerife and Gran Canaria (Canary Islands) finding the presence of diethyl phthalate, diallyl phthalate, dipropyl phthalate, benzylbutyl phthalate, di-n-butyl phthalate, bis-(2-n-butoxyethyl) phthalate, di-n-pentyl phthalate, dicyclohexyl phthalate, and bis-(2-ethylhexyl) phthalate at concentrations between 105.2 and 3414 ng/L. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-021-03166-1.
format Online
Article
Text
id pubmed-7856334
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-78563342021-02-03 Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants Santana-Mayor, Álvaro Socas-Rodríguez, Bárbara Rodríguez-Ramos, Ruth Herrera-Herrera, Antonio V. Rodríguez-Delgado, Miguel Ángel Anal Bioanal Chem Research Paper A non-ionic hydrophobic natural deep eutectic solvent (HNADES) based on thymol and menthol was proposed for the liquid-liquid microextraction of fourteen phthalates and one adipate from environmental water samples. Separation, identification, and quantification were achieved by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry. The main factors affecting the extraction efficiency were thoroughly studied. Sample pH of 8 and 100 μL of thymol:menthol at molar ratio 2:1 were selected as the best conditions, while ionic strength and type of dispersant solvent were not relevant for the extraction of the target compounds. The whole methodology was validated for treated wastewater, runoff, and pond water matrices, using di-n-butyl phthalate-3,4,5,6-d(4) and dihexyl phthalate-3,4,5,6-d(4) as surrogates. Recovery ranged from 70 to 127% with relative standard deviation values lower than 14%. Limits of quantification of the method were in the range 0.042–0.425 μg/L for treated wastewater, 0.015–0.386 μg/L for runoff, and 0.013–0.376 μg/L for pond water. The methodology was applied for the analysis of real treated wastewater, runoff, and pond water samples from different places of Tenerife and Gran Canaria (Canary Islands) finding the presence of diethyl phthalate, diallyl phthalate, dipropyl phthalate, benzylbutyl phthalate, di-n-butyl phthalate, bis-(2-n-butoxyethyl) phthalate, di-n-pentyl phthalate, dicyclohexyl phthalate, and bis-(2-ethylhexyl) phthalate at concentrations between 105.2 and 3414 ng/L. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-021-03166-1. Springer Berlin Heidelberg 2021-02-03 2021 /pmc/articles/PMC7856334/ /pubmed/33534021 http://dx.doi.org/10.1007/s00216-021-03166-1 Text en © Springer-Verlag GmbH Germany, part of Springer Nature 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research Paper
Santana-Mayor, Álvaro
Socas-Rodríguez, Bárbara
Rodríguez-Ramos, Ruth
Herrera-Herrera, Antonio V.
Rodríguez-Delgado, Miguel Ángel
Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
title Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
title_full Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
title_fullStr Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
title_full_unstemmed Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
title_short Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
title_sort quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856334/
https://www.ncbi.nlm.nih.gov/pubmed/33534021
http://dx.doi.org/10.1007/s00216-021-03166-1
work_keys_str_mv AT santanamayoralvaro qualityassessmentofenvironmentalwaterbyasimpleandfastnonionichydrophobicnaturaldeepeutecticsolventbasedextractionprocedurecombinedwithliquidchromatographytandemmassspectrometryforthedeterminationofplasticmigrants
AT socasrodriguezbarbara qualityassessmentofenvironmentalwaterbyasimpleandfastnonionichydrophobicnaturaldeepeutecticsolventbasedextractionprocedurecombinedwithliquidchromatographytandemmassspectrometryforthedeterminationofplasticmigrants
AT rodriguezramosruth qualityassessmentofenvironmentalwaterbyasimpleandfastnonionichydrophobicnaturaldeepeutecticsolventbasedextractionprocedurecombinedwithliquidchromatographytandemmassspectrometryforthedeterminationofplasticmigrants
AT herreraherreraantoniov qualityassessmentofenvironmentalwaterbyasimpleandfastnonionichydrophobicnaturaldeepeutecticsolventbasedextractionprocedurecombinedwithliquidchromatographytandemmassspectrometryforthedeterminationofplasticmigrants
AT rodriguezdelgadomiguelangel qualityassessmentofenvironmentalwaterbyasimpleandfastnonionichydrophobicnaturaldeepeutecticsolventbasedextractionprocedurecombinedwithliquidchromatographytandemmassspectrometryforthedeterminationofplasticmigrants