Cargando…

Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial

PURPOSE: The aim of the present study based on the PriCoTTF‐phase I/II trial is the quantification of skin‐normal tissue complication probabilities of patients with newly diagnosed glioblastoma multiforme treated with Tumor Treating Field (TTField) electrodes, concurrent radiotherapy, and temozolomi...

Descripción completa

Detalles Bibliográficos
Autores principales: Nour, Youness, Pöttgen, Christoph, Kebir, Sied, Lazaridis, Lazaros, Lüdemann, Lutz, Guberina, Maja, Gauler, Thomas, Scheffler, Björn, Jabbarli, Ramazan, Pierscianek, Daniela, Sure, Ulrich, Schmidt, Teresa, Oster, Christoph, Hau, Peter, Glas, Martin, Lübcke, Wolfgang, Stuschke, Martin, Guberina, Nika
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856507/
https://www.ncbi.nlm.nih.gov/pubmed/33389825
http://dx.doi.org/10.1002/acm2.13144
_version_ 1783646265386467328
author Nour, Youness
Pöttgen, Christoph
Kebir, Sied
Lazaridis, Lazaros
Lüdemann, Lutz
Guberina, Maja
Gauler, Thomas
Scheffler, Björn
Jabbarli, Ramazan
Pierscianek, Daniela
Sure, Ulrich
Schmidt, Teresa
Oster, Christoph
Hau, Peter
Glas, Martin
Lübcke, Wolfgang
Stuschke, Martin
Guberina, Nika
author_facet Nour, Youness
Pöttgen, Christoph
Kebir, Sied
Lazaridis, Lazaros
Lüdemann, Lutz
Guberina, Maja
Gauler, Thomas
Scheffler, Björn
Jabbarli, Ramazan
Pierscianek, Daniela
Sure, Ulrich
Schmidt, Teresa
Oster, Christoph
Hau, Peter
Glas, Martin
Lübcke, Wolfgang
Stuschke, Martin
Guberina, Nika
author_sort Nour, Youness
collection PubMed
description PURPOSE: The aim of the present study based on the PriCoTTF‐phase I/II trial is the quantification of skin‐normal tissue complication probabilities of patients with newly diagnosed glioblastoma multiforme treated with Tumor Treating Field (TTField) electrodes, concurrent radiotherapy, and temozolomide. Furthermore, the skin‐sparing effect by the clinically applied strategy of repetitive transducer array fixation around their center position shall be examined. MATERIAL AND METHODS: Low‐dose cone‐beam computed tomography (CBCT) scans of all fractions of the first seven patients of the PriCoTTF‐phase I/II trial, used for image guidance, were applied for the dosimetric analysis, for precise TTField transducer array positioning and contour delineation. Within this trial, array positioning was varied from fixation‐to‐fixation period with a standard deviation of 1.1 cm in the direction of the largest variation of positioning and 0.7 cm in the perpendicular direction. Physical TTField electrode composition was examined and a respective Hounsfield Unit attributed to the TTField electrodes. Dose distributions in the planning CT with TTField electrodes in place, as derived from prefraction CBCTs, were calculated and accumulated with the algorithm Acuros XB. Dose‐volume histograms were obtained for the first and second 2 mm scalp layer with and without migrating electrodes and compared with those with fixed electrodes in an average position. Skin toxicity was quantified according to Lyman's model. Minimum doses in hot‐spots of 0.05 cm(2) and 25 cm(2) ([Formula: see text] D(0.05cm) (2), [Formula: see text] D(25cm) (2)) size in the superficial skin layers were analyzed. RESULTS: Normal tissue complication probabilities (NTCPs) for skin necrosis ranged from 0.005% to 1.474% (median 0.111%) for the different patients without electrodes. NTCP logarithms were significantly dependent on patient (P < 0.0001) and scenario (P < 0.0001) as classification variables. Fixed positioning of TTField arrays increased skin‐NTCP by a factor of 5.50 (95%, CI: 3.66–8.27). The variation of array positioning increased skin‐NTCP by a factor of only 3.54 (95%, CI: 2.36–5.32) (P < 0.0001, comparison to irradiation without electrodes; P = 0.036, comparison to irradiation with fixed electrodes). NTCP showed a significant rank correlation with D25cm(2) over all patients and scenarios (r(s) = 0.76; P < 0.0001). CONCLUSION: Skin‐NTCP calculation uncovers significant interpatient heterogeneity and may be used to stratify patients into high‐ and low‐risk groups of skin toxicity. Array position variation may mitigate about one‐third of the increase in surface dose and skin‐NTCP by the TTField electrodes.
format Online
Article
Text
id pubmed-7856507
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-78565072021-02-05 Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial Nour, Youness Pöttgen, Christoph Kebir, Sied Lazaridis, Lazaros Lüdemann, Lutz Guberina, Maja Gauler, Thomas Scheffler, Björn Jabbarli, Ramazan Pierscianek, Daniela Sure, Ulrich Schmidt, Teresa Oster, Christoph Hau, Peter Glas, Martin Lübcke, Wolfgang Stuschke, Martin Guberina, Nika J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: The aim of the present study based on the PriCoTTF‐phase I/II trial is the quantification of skin‐normal tissue complication probabilities of patients with newly diagnosed glioblastoma multiforme treated with Tumor Treating Field (TTField) electrodes, concurrent radiotherapy, and temozolomide. Furthermore, the skin‐sparing effect by the clinically applied strategy of repetitive transducer array fixation around their center position shall be examined. MATERIAL AND METHODS: Low‐dose cone‐beam computed tomography (CBCT) scans of all fractions of the first seven patients of the PriCoTTF‐phase I/II trial, used for image guidance, were applied for the dosimetric analysis, for precise TTField transducer array positioning and contour delineation. Within this trial, array positioning was varied from fixation‐to‐fixation period with a standard deviation of 1.1 cm in the direction of the largest variation of positioning and 0.7 cm in the perpendicular direction. Physical TTField electrode composition was examined and a respective Hounsfield Unit attributed to the TTField electrodes. Dose distributions in the planning CT with TTField electrodes in place, as derived from prefraction CBCTs, were calculated and accumulated with the algorithm Acuros XB. Dose‐volume histograms were obtained for the first and second 2 mm scalp layer with and without migrating electrodes and compared with those with fixed electrodes in an average position. Skin toxicity was quantified according to Lyman's model. Minimum doses in hot‐spots of 0.05 cm(2) and 25 cm(2) ([Formula: see text] D(0.05cm) (2), [Formula: see text] D(25cm) (2)) size in the superficial skin layers were analyzed. RESULTS: Normal tissue complication probabilities (NTCPs) for skin necrosis ranged from 0.005% to 1.474% (median 0.111%) for the different patients without electrodes. NTCP logarithms were significantly dependent on patient (P < 0.0001) and scenario (P < 0.0001) as classification variables. Fixed positioning of TTField arrays increased skin‐NTCP by a factor of 5.50 (95%, CI: 3.66–8.27). The variation of array positioning increased skin‐NTCP by a factor of only 3.54 (95%, CI: 2.36–5.32) (P < 0.0001, comparison to irradiation without electrodes; P = 0.036, comparison to irradiation with fixed electrodes). NTCP showed a significant rank correlation with D25cm(2) over all patients and scenarios (r(s) = 0.76; P < 0.0001). CONCLUSION: Skin‐NTCP calculation uncovers significant interpatient heterogeneity and may be used to stratify patients into high‐ and low‐risk groups of skin toxicity. Array position variation may mitigate about one‐third of the increase in surface dose and skin‐NTCP by the TTField electrodes. John Wiley and Sons Inc. 2021-01-03 /pmc/articles/PMC7856507/ /pubmed/33389825 http://dx.doi.org/10.1002/acm2.13144 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Nour, Youness
Pöttgen, Christoph
Kebir, Sied
Lazaridis, Lazaros
Lüdemann, Lutz
Guberina, Maja
Gauler, Thomas
Scheffler, Björn
Jabbarli, Ramazan
Pierscianek, Daniela
Sure, Ulrich
Schmidt, Teresa
Oster, Christoph
Hau, Peter
Glas, Martin
Lübcke, Wolfgang
Stuschke, Martin
Guberina, Nika
Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
title Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
title_full Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
title_fullStr Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
title_full_unstemmed Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
title_short Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
title_sort dosimetric impact of the positioning variation of tumor treating field electrodes in the pricottf‐phase i/ii trial
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856507/
https://www.ncbi.nlm.nih.gov/pubmed/33389825
http://dx.doi.org/10.1002/acm2.13144
work_keys_str_mv AT nouryouness dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT pottgenchristoph dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT kebirsied dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT lazaridislazaros dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT ludemannlutz dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT guberinamaja dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT gaulerthomas dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT schefflerbjorn dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT jabbarliramazan dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT pierscianekdaniela dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT sureulrich dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT schmidtteresa dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT osterchristoph dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT haupeter dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT glasmartin dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT lubckewolfgang dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT stuschkemartin dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial
AT guberinanika dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial