Cargando…
Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial
PURPOSE: The aim of the present study based on the PriCoTTF‐phase I/II trial is the quantification of skin‐normal tissue complication probabilities of patients with newly diagnosed glioblastoma multiforme treated with Tumor Treating Field (TTField) electrodes, concurrent radiotherapy, and temozolomi...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856507/ https://www.ncbi.nlm.nih.gov/pubmed/33389825 http://dx.doi.org/10.1002/acm2.13144 |
_version_ | 1783646265386467328 |
---|---|
author | Nour, Youness Pöttgen, Christoph Kebir, Sied Lazaridis, Lazaros Lüdemann, Lutz Guberina, Maja Gauler, Thomas Scheffler, Björn Jabbarli, Ramazan Pierscianek, Daniela Sure, Ulrich Schmidt, Teresa Oster, Christoph Hau, Peter Glas, Martin Lübcke, Wolfgang Stuschke, Martin Guberina, Nika |
author_facet | Nour, Youness Pöttgen, Christoph Kebir, Sied Lazaridis, Lazaros Lüdemann, Lutz Guberina, Maja Gauler, Thomas Scheffler, Björn Jabbarli, Ramazan Pierscianek, Daniela Sure, Ulrich Schmidt, Teresa Oster, Christoph Hau, Peter Glas, Martin Lübcke, Wolfgang Stuschke, Martin Guberina, Nika |
author_sort | Nour, Youness |
collection | PubMed |
description | PURPOSE: The aim of the present study based on the PriCoTTF‐phase I/II trial is the quantification of skin‐normal tissue complication probabilities of patients with newly diagnosed glioblastoma multiforme treated with Tumor Treating Field (TTField) electrodes, concurrent radiotherapy, and temozolomide. Furthermore, the skin‐sparing effect by the clinically applied strategy of repetitive transducer array fixation around their center position shall be examined. MATERIAL AND METHODS: Low‐dose cone‐beam computed tomography (CBCT) scans of all fractions of the first seven patients of the PriCoTTF‐phase I/II trial, used for image guidance, were applied for the dosimetric analysis, for precise TTField transducer array positioning and contour delineation. Within this trial, array positioning was varied from fixation‐to‐fixation period with a standard deviation of 1.1 cm in the direction of the largest variation of positioning and 0.7 cm in the perpendicular direction. Physical TTField electrode composition was examined and a respective Hounsfield Unit attributed to the TTField electrodes. Dose distributions in the planning CT with TTField electrodes in place, as derived from prefraction CBCTs, were calculated and accumulated with the algorithm Acuros XB. Dose‐volume histograms were obtained for the first and second 2 mm scalp layer with and without migrating electrodes and compared with those with fixed electrodes in an average position. Skin toxicity was quantified according to Lyman's model. Minimum doses in hot‐spots of 0.05 cm(2) and 25 cm(2) ([Formula: see text] D(0.05cm) (2), [Formula: see text] D(25cm) (2)) size in the superficial skin layers were analyzed. RESULTS: Normal tissue complication probabilities (NTCPs) for skin necrosis ranged from 0.005% to 1.474% (median 0.111%) for the different patients without electrodes. NTCP logarithms were significantly dependent on patient (P < 0.0001) and scenario (P < 0.0001) as classification variables. Fixed positioning of TTField arrays increased skin‐NTCP by a factor of 5.50 (95%, CI: 3.66–8.27). The variation of array positioning increased skin‐NTCP by a factor of only 3.54 (95%, CI: 2.36–5.32) (P < 0.0001, comparison to irradiation without electrodes; P = 0.036, comparison to irradiation with fixed electrodes). NTCP showed a significant rank correlation with D25cm(2) over all patients and scenarios (r(s) = 0.76; P < 0.0001). CONCLUSION: Skin‐NTCP calculation uncovers significant interpatient heterogeneity and may be used to stratify patients into high‐ and low‐risk groups of skin toxicity. Array position variation may mitigate about one‐third of the increase in surface dose and skin‐NTCP by the TTField electrodes. |
format | Online Article Text |
id | pubmed-7856507 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78565072021-02-05 Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial Nour, Youness Pöttgen, Christoph Kebir, Sied Lazaridis, Lazaros Lüdemann, Lutz Guberina, Maja Gauler, Thomas Scheffler, Björn Jabbarli, Ramazan Pierscianek, Daniela Sure, Ulrich Schmidt, Teresa Oster, Christoph Hau, Peter Glas, Martin Lübcke, Wolfgang Stuschke, Martin Guberina, Nika J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: The aim of the present study based on the PriCoTTF‐phase I/II trial is the quantification of skin‐normal tissue complication probabilities of patients with newly diagnosed glioblastoma multiforme treated with Tumor Treating Field (TTField) electrodes, concurrent radiotherapy, and temozolomide. Furthermore, the skin‐sparing effect by the clinically applied strategy of repetitive transducer array fixation around their center position shall be examined. MATERIAL AND METHODS: Low‐dose cone‐beam computed tomography (CBCT) scans of all fractions of the first seven patients of the PriCoTTF‐phase I/II trial, used for image guidance, were applied for the dosimetric analysis, for precise TTField transducer array positioning and contour delineation. Within this trial, array positioning was varied from fixation‐to‐fixation period with a standard deviation of 1.1 cm in the direction of the largest variation of positioning and 0.7 cm in the perpendicular direction. Physical TTField electrode composition was examined and a respective Hounsfield Unit attributed to the TTField electrodes. Dose distributions in the planning CT with TTField electrodes in place, as derived from prefraction CBCTs, were calculated and accumulated with the algorithm Acuros XB. Dose‐volume histograms were obtained for the first and second 2 mm scalp layer with and without migrating electrodes and compared with those with fixed electrodes in an average position. Skin toxicity was quantified according to Lyman's model. Minimum doses in hot‐spots of 0.05 cm(2) and 25 cm(2) ([Formula: see text] D(0.05cm) (2), [Formula: see text] D(25cm) (2)) size in the superficial skin layers were analyzed. RESULTS: Normal tissue complication probabilities (NTCPs) for skin necrosis ranged from 0.005% to 1.474% (median 0.111%) for the different patients without electrodes. NTCP logarithms were significantly dependent on patient (P < 0.0001) and scenario (P < 0.0001) as classification variables. Fixed positioning of TTField arrays increased skin‐NTCP by a factor of 5.50 (95%, CI: 3.66–8.27). The variation of array positioning increased skin‐NTCP by a factor of only 3.54 (95%, CI: 2.36–5.32) (P < 0.0001, comparison to irradiation without electrodes; P = 0.036, comparison to irradiation with fixed electrodes). NTCP showed a significant rank correlation with D25cm(2) over all patients and scenarios (r(s) = 0.76; P < 0.0001). CONCLUSION: Skin‐NTCP calculation uncovers significant interpatient heterogeneity and may be used to stratify patients into high‐ and low‐risk groups of skin toxicity. Array position variation may mitigate about one‐third of the increase in surface dose and skin‐NTCP by the TTField electrodes. John Wiley and Sons Inc. 2021-01-03 /pmc/articles/PMC7856507/ /pubmed/33389825 http://dx.doi.org/10.1002/acm2.13144 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Nour, Youness Pöttgen, Christoph Kebir, Sied Lazaridis, Lazaros Lüdemann, Lutz Guberina, Maja Gauler, Thomas Scheffler, Björn Jabbarli, Ramazan Pierscianek, Daniela Sure, Ulrich Schmidt, Teresa Oster, Christoph Hau, Peter Glas, Martin Lübcke, Wolfgang Stuschke, Martin Guberina, Nika Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial |
title | Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial |
title_full | Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial |
title_fullStr | Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial |
title_full_unstemmed | Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial |
title_short | Dosimetric impact of the positioning variation of tumor treating field electrodes in the PriCoTTF‐phase I/II trial |
title_sort | dosimetric impact of the positioning variation of tumor treating field electrodes in the pricottf‐phase i/ii trial |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856507/ https://www.ncbi.nlm.nih.gov/pubmed/33389825 http://dx.doi.org/10.1002/acm2.13144 |
work_keys_str_mv | AT nouryouness dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT pottgenchristoph dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT kebirsied dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT lazaridislazaros dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT ludemannlutz dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT guberinamaja dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT gaulerthomas dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT schefflerbjorn dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT jabbarliramazan dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT pierscianekdaniela dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT sureulrich dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT schmidtteresa dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT osterchristoph dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT haupeter dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT glasmartin dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT lubckewolfgang dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT stuschkemartin dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial AT guberinanika dosimetricimpactofthepositioningvariationoftumortreatingfieldelectrodesinthepricottfphaseiiitrial |