Cargando…

Customized laser vision correction for irregular cornea post-refractive surgery

Ablation-related complications following the refractive procedures are a major challenge for a refractive surgeon, considering the elective nature of the procedure. The use of topography-guided customized ablation has revolutionized the management of irregular corneas postrefractive surgery. This pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Shetty, Rohit, Lalgudi, Vaitheeshwaran Ganesan, Kaweri, Luci, Choudhary, Urvija, Chabra, Aishwariya, Gupta, Krati, Khamar, Pooja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856932/
https://www.ncbi.nlm.nih.gov/pubmed/33229662
http://dx.doi.org/10.4103/ijo.IJO_2793_20
_version_ 1783646342891962368
author Shetty, Rohit
Lalgudi, Vaitheeshwaran Ganesan
Kaweri, Luci
Choudhary, Urvija
Chabra, Aishwariya
Gupta, Krati
Khamar, Pooja
author_facet Shetty, Rohit
Lalgudi, Vaitheeshwaran Ganesan
Kaweri, Luci
Choudhary, Urvija
Chabra, Aishwariya
Gupta, Krati
Khamar, Pooja
author_sort Shetty, Rohit
collection PubMed
description Ablation-related complications following the refractive procedures are a major challenge for a refractive surgeon, considering the elective nature of the procedure. The use of topography-guided customized ablation has revolutionized the management of irregular corneas postrefractive surgery. This preferred practice highlights various hurdles encountered while managing cases of decentered ablation, small ablation zones, and planning a cataract surgery in patients with irregular corneas. It will give insight to the refractive surgeon on the planning of corneal regularization on various modern-day refractive platforms available, such as the WaveLight(®) EX-500 (Alcon Laboratories, Inc., Fort Worth, TX, USA), Schwind Amaris 1050 (Peramis; SCHWIND eye-tech-solutions, Kleinostheim, Germany), and Technolas Teneo 317 model 2 excimer laser (Bausch & Lomb, Rochester, NY, USA). The algorithmic approach outlined will enable the refractive surgeon to choose between the wavefront optomized and the topography-guided ablations.
format Online
Article
Text
id pubmed-7856932
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-78569322021-02-05 Customized laser vision correction for irregular cornea post-refractive surgery Shetty, Rohit Lalgudi, Vaitheeshwaran Ganesan Kaweri, Luci Choudhary, Urvija Chabra, Aishwariya Gupta, Krati Khamar, Pooja Indian J Ophthalmol Preferred Practice Ablation-related complications following the refractive procedures are a major challenge for a refractive surgeon, considering the elective nature of the procedure. The use of topography-guided customized ablation has revolutionized the management of irregular corneas postrefractive surgery. This preferred practice highlights various hurdles encountered while managing cases of decentered ablation, small ablation zones, and planning a cataract surgery in patients with irregular corneas. It will give insight to the refractive surgeon on the planning of corneal regularization on various modern-day refractive platforms available, such as the WaveLight(®) EX-500 (Alcon Laboratories, Inc., Fort Worth, TX, USA), Schwind Amaris 1050 (Peramis; SCHWIND eye-tech-solutions, Kleinostheim, Germany), and Technolas Teneo 317 model 2 excimer laser (Bausch & Lomb, Rochester, NY, USA). The algorithmic approach outlined will enable the refractive surgeon to choose between the wavefront optomized and the topography-guided ablations. Wolters Kluwer - Medknow 2020-12 2020-11-23 /pmc/articles/PMC7856932/ /pubmed/33229662 http://dx.doi.org/10.4103/ijo.IJO_2793_20 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Preferred Practice
Shetty, Rohit
Lalgudi, Vaitheeshwaran Ganesan
Kaweri, Luci
Choudhary, Urvija
Chabra, Aishwariya
Gupta, Krati
Khamar, Pooja
Customized laser vision correction for irregular cornea post-refractive surgery
title Customized laser vision correction for irregular cornea post-refractive surgery
title_full Customized laser vision correction for irregular cornea post-refractive surgery
title_fullStr Customized laser vision correction for irregular cornea post-refractive surgery
title_full_unstemmed Customized laser vision correction for irregular cornea post-refractive surgery
title_short Customized laser vision correction for irregular cornea post-refractive surgery
title_sort customized laser vision correction for irregular cornea post-refractive surgery
topic Preferred Practice
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856932/
https://www.ncbi.nlm.nih.gov/pubmed/33229662
http://dx.doi.org/10.4103/ijo.IJO_2793_20
work_keys_str_mv AT shettyrohit customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery
AT lalgudivaitheeshwaranganesan customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery
AT kaweriluci customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery
AT choudharyurvija customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery
AT chabraaishwariya customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery
AT guptakrati customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery
AT khamarpooja customizedlaservisioncorrectionforirregularcorneapostrefractivesurgery