Cargando…

Comparative analysis of predictability and accuracy of American Society of Cataract and Refractive Surgery online calculator with Haigis-L formula in post-myopic laser-assisted in-situ keratomileusis refractive surgery eyes

PURPOSE: The aim of this study was to compare the predictability and accuracy of the American Society of Cataract and Refractive Surgery (ASCRS) online calculator with the Haigis-L formula for intraocular lens (IOL) power calculation in post myopic laser-assisted in-situ keratomileuses (LASIK) eyes...

Descripción completa

Detalles Bibliográficos
Autores principales: Menon, P Ramya, Shekhar, Madhu, Sankarananthan, R, Agarwal, Neha, Dhanya, CA, Wijesinghe, Hiruni K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856948/
https://www.ncbi.nlm.nih.gov/pubmed/33229682
http://dx.doi.org/10.4103/ijo.IJO_2494_20
Descripción
Sumario:PURPOSE: The aim of this study was to compare the predictability and accuracy of the American Society of Cataract and Refractive Surgery (ASCRS) online calculator with the Haigis-L formula for intraocular lens (IOL) power calculation in post myopic laser-assisted in-situ keratomileuses (LASIK) eyes undergoing cataract surgery and also to analyze the postoperative refractive outcome among the ASCRS average, maximum and minimum values. METHODS: A retrospective study was conducted on post myopic LASIK eyes which underwent cataract surgery between June 2017 and December 2019. IOL power was calculated using both Haigis-L & ASCRS methods. Implanted IOL power was based on the ASCRS method. The expected postoperative refraction for IOL power based on the Haigis-L formula was calculated and compared with the Spherical Equivalent (SE) obtained from the patient's actual refraction. Prediction error (PE) & Mean Absolute Error (MAE) was calculated. Intragroup analysis of ASCRS values was done. RESULTS: Among the 41 eyes analyzed, pre-operative and post-operative mean best-corrected visual acuity was 0.58 ± 0.21 and 0.15 ± 0.26 logMAR, respectively. In the ASCRS method, 36 (87.8%) and 40 (97.6%) eyes had PE within ± 0.5D and ± 1.0 D, respectively, whereas, in the Haigis-L method, 29 (70.7%) eyes, and 38 (92.7%) eyes had PE within ± 0.5D and ± 1.0 D, respectively. Among the ASCRS subgroups, ASCRS average, maximum and minimum values had 83%, 80.6%, and 48.8% eyes with SE within ± 0.5D, respectively. CONCLUSION: ASCRS method can be considered as an equally efficient method of IOL power calculation as the Haigis-L method in eyes which have undergone post myopic LASIK refractive surgery. ASCRS maximum & average values gave better emmetropic results.