Cargando…
Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
Pellucid marginal corneal degeneration (PMCD) is a progressive corneal ectasia that ultimately results in high regular astigmatism and correction of this astigmatism is always challenging. However, when a PMCD patient develops a cataract, it provides a golden opportunity to treat this coexisting ast...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7857004/ https://www.ncbi.nlm.nih.gov/pubmed/33245061 http://dx.doi.org/10.4103/ijo.IJO_2943_20 |
_version_ | 1783646359636672512 |
---|---|
author | Matalia, Himanshu Nandini, Chinnappaiah Matalia, Jyoti |
author_facet | Matalia, Himanshu Nandini, Chinnappaiah Matalia, Jyoti |
author_sort | Matalia, Himanshu |
collection | PubMed |
description | Pellucid marginal corneal degeneration (PMCD) is a progressive corneal ectasia that ultimately results in high regular astigmatism and correction of this astigmatism is always challenging. However, when a PMCD patient develops a cataract, it provides a golden opportunity to treat this coexisting astigmatism with toric intraocular lens (IOL) implantation. Regular toric IOLs would correct astigmatism only up to 6 diopters in the IOL plane but higher astigmatism would require customization of such IOLs. Our case report describes the long term outcomes of customized toric IOL to tackle this high astigmatism during cataract surgery in PMCD cases. |
format | Online Article Text |
id | pubmed-7857004 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-78570042021-02-05 Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration Matalia, Himanshu Nandini, Chinnappaiah Matalia, Jyoti Indian J Ophthalmol Case Reports Pellucid marginal corneal degeneration (PMCD) is a progressive corneal ectasia that ultimately results in high regular astigmatism and correction of this astigmatism is always challenging. However, when a PMCD patient develops a cataract, it provides a golden opportunity to treat this coexisting astigmatism with toric intraocular lens (IOL) implantation. Regular toric IOLs would correct astigmatism only up to 6 diopters in the IOL plane but higher astigmatism would require customization of such IOLs. Our case report describes the long term outcomes of customized toric IOL to tackle this high astigmatism during cataract surgery in PMCD cases. Medknow Publications & Media Pvt Ltd 2020-12 2020-11-23 /pmc/articles/PMC7857004/ /pubmed/33245061 http://dx.doi.org/10.4103/ijo.IJO_2943_20 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Reports Matalia, Himanshu Nandini, Chinnappaiah Matalia, Jyoti Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
title | Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
title_full | Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
title_fullStr | Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
title_full_unstemmed | Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
title_short | Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
title_sort | long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7857004/ https://www.ncbi.nlm.nih.gov/pubmed/33245061 http://dx.doi.org/10.4103/ijo.IJO_2943_20 |
work_keys_str_mv | AT mataliahimanshu longtermoutcomeofcustomtoricintraocularlensfortreatinghighastigmatismincaseofcataractassociatedwithpellucidmarginalcornealdegeneration AT nandinichinnappaiah longtermoutcomeofcustomtoricintraocularlensfortreatinghighastigmatismincaseofcataractassociatedwithpellucidmarginalcornealdegeneration AT mataliajyoti longtermoutcomeofcustomtoricintraocularlensfortreatinghighastigmatismincaseofcataractassociatedwithpellucidmarginalcornealdegeneration |