Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration

Pellucid marginal corneal degeneration (PMCD) is a progressive corneal ectasia that ultimately results in high regular astigmatism and correction of this astigmatism is always challenging. However, when a PMCD patient develops a cataract, it provides a golden opportunity to treat this coexisting ast...

Descripción completa

Detalles Bibliográficos
Autores principales: Matalia, Himanshu, Nandini, Chinnappaiah, Matalia, Jyoti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7857004/
https://www.ncbi.nlm.nih.gov/pubmed/33245061
http://dx.doi.org/10.4103/ijo.IJO_2943_20
_version_ 1783646359636672512
author Matalia, Himanshu
Nandini, Chinnappaiah
Matalia, Jyoti
author_facet Matalia, Himanshu
Nandini, Chinnappaiah
Matalia, Jyoti
author_sort Matalia, Himanshu
collection PubMed
description Pellucid marginal corneal degeneration (PMCD) is a progressive corneal ectasia that ultimately results in high regular astigmatism and correction of this astigmatism is always challenging. However, when a PMCD patient develops a cataract, it provides a golden opportunity to treat this coexisting astigmatism with toric intraocular lens (IOL) implantation. Regular toric IOLs would correct astigmatism only up to 6 diopters in the IOL plane but higher astigmatism would require customization of such IOLs. Our case report describes the long term outcomes of customized toric IOL to tackle this high astigmatism during cataract surgery in PMCD cases.
format Online
Article
Text
id pubmed-7857004
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-78570042021-02-05 Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration Matalia, Himanshu Nandini, Chinnappaiah Matalia, Jyoti Indian J Ophthalmol Case Reports Pellucid marginal corneal degeneration (PMCD) is a progressive corneal ectasia that ultimately results in high regular astigmatism and correction of this astigmatism is always challenging. However, when a PMCD patient develops a cataract, it provides a golden opportunity to treat this coexisting astigmatism with toric intraocular lens (IOL) implantation. Regular toric IOLs would correct astigmatism only up to 6 diopters in the IOL plane but higher astigmatism would require customization of such IOLs. Our case report describes the long term outcomes of customized toric IOL to tackle this high astigmatism during cataract surgery in PMCD cases. Medknow Publications & Media Pvt Ltd 2020-12 2020-11-23 /pmc/articles/PMC7857004/ /pubmed/33245061 http://dx.doi.org/10.4103/ijo.IJO_2943_20 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Case Reports
Matalia, Himanshu
Nandini, Chinnappaiah
Matalia, Jyoti
Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
title Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
title_full Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
title_fullStr Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
title_full_unstemmed Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
title_short Long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
title_sort long-term outcome of custom toric intraocular lens for treating high astigmatism in case of cataract associated with pellucid marginal corneal degeneration
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7857004/
https://www.ncbi.nlm.nih.gov/pubmed/33245061
http://dx.doi.org/10.4103/ijo.IJO_2943_20
work_keys_str_mv AT mataliahimanshu longtermoutcomeofcustomtoricintraocularlensfortreatinghighastigmatismincaseofcataractassociatedwithpellucidmarginalcornealdegeneration
AT nandinichinnappaiah longtermoutcomeofcustomtoricintraocularlensfortreatinghighastigmatismincaseofcataractassociatedwithpellucidmarginalcornealdegeneration
AT mataliajyoti longtermoutcomeofcustomtoricintraocularlensfortreatinghighastigmatismincaseofcataractassociatedwithpellucidmarginalcornealdegeneration