Cargando…
Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study
BACKGROUND: Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of tempera...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7860630/ https://www.ncbi.nlm.nih.gov/pubmed/33541324 http://dx.doi.org/10.1186/s12891-020-03918-7 |
_version_ | 1783646918683918336 |
---|---|
author | Rodríguez-Sanz, Jacobo López-de-Celis, Carlos Hidalgo-García, César Canet-Vintró, Max Fanlo-Mazas, Pablo Pérez-Bellmunt, Albert |
author_facet | Rodríguez-Sanz, Jacobo López-de-Celis, Carlos Hidalgo-García, César Canet-Vintró, Max Fanlo-Mazas, Pablo Pérez-Bellmunt, Albert |
author_sort | Rodríguez-Sanz, Jacobo |
collection | PubMed |
description | BACKGROUND: Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode. METHODS: A cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5 min each by a diathermy “T-Plus” device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. RESULTS: A statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P< 0.035). All the applications showed a 5 min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% ± 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% ± 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% ± 22.96 at 5-min at the superficial level, and 32% ± 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% ± 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level. CONCLUSION: The shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area. |
format | Online Article Text |
id | pubmed-7860630 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-78606302021-02-05 Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study Rodríguez-Sanz, Jacobo López-de-Celis, Carlos Hidalgo-García, César Canet-Vintró, Max Fanlo-Mazas, Pablo Pérez-Bellmunt, Albert BMC Musculoskelet Disord Research Article BACKGROUND: Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode. METHODS: A cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5 min each by a diathermy “T-Plus” device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. RESULTS: A statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P< 0.035). All the applications showed a 5 min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% ± 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% ± 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% ± 22.96 at 5-min at the superficial level, and 32% ± 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% ± 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level. CONCLUSION: The shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area. BioMed Central 2021-02-04 /pmc/articles/PMC7860630/ /pubmed/33541324 http://dx.doi.org/10.1186/s12891-020-03918-7 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Rodríguez-Sanz, Jacobo López-de-Celis, Carlos Hidalgo-García, César Canet-Vintró, Max Fanlo-Mazas, Pablo Pérez-Bellmunt, Albert Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
title | Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
title_full | Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
title_fullStr | Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
title_full_unstemmed | Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
title_short | Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
title_sort | temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7860630/ https://www.ncbi.nlm.nih.gov/pubmed/33541324 http://dx.doi.org/10.1186/s12891-020-03918-7 |
work_keys_str_mv | AT rodriguezsanzjacobo temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy AT lopezdeceliscarlos temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy AT hidalgogarciacesar temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy AT canetvintromax temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy AT fanlomazaspablo temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy AT perezbellmuntalbert temperatureandcurrentfloweffectsofdifferentelectrodeplacementinshouldercapacitiveresistiveelectrictransferapplicationsacadavericstudy |