Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation
Background: Vaginitis is a common and very private disease, and the current diagnosis is a frequent go to the hospital for testing. Objective: In order to improve the convenience and speed of detection, in this paper, we have developed a hand-held zoom micro-imaging system based on a microfluidic ch...
Formato: | Online Artículo Texto |
---|---|
Lenguaje: | English |
Publicado: |
IEEE
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7861347/ https://www.ncbi.nlm.nih.gov/pubmed/33552751 http://dx.doi.org/10.1109/JTEHM.2021.3054556 |
_version_ | 1783647067284963328 |
---|---|
collection | PubMed |
description | Background: Vaginitis is a common and very private disease, and the current diagnosis is a frequent go to the hospital for testing. Objective: In order to improve the convenience and speed of detection, in this paper, we have developed a hand-held zoom micro-imaging system based on a microfluidic chip for point-of-care testing (POCT) of vaginal inflammation. Methods: This system consists of a microfluidic chip, an optical system and a hand-held zoom system assembled with a mobile phone. In terms of hardware, we designed a self-priming microfluidic chip, which can realize automatic sampling and full mixing of samples. We have also developed an optical system that can be adapted to smartphones, which has a lens group with a 37x magnification function and equipped with a zoom system with a focus range of 4mm to 6mm. In terms of software, we proposed an APP that can accurately identify cocci and can determine the inflammation level. Results: Compared with the recognition rate of the observers in the hospital, the detection accuracy of the portable recognition system is 95%, and after testing the clinical samples, the results were completely consistent with the hospital diagnosis results. The detection limit was 500 CFU / ml, which the relative error was (0.9 ± 0.3) %, and recognition time is 7 seconds. Conclusion: This system is definitely suitable for women’s point-of-care testing (POCT). |
format | Online Article Text |
id | pubmed-7861347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | IEEE |
record_format | MEDLINE/PubMed |
spelling | pubmed-78613472021-02-05 Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation IEEE J Transl Eng Health Med Article Background: Vaginitis is a common and very private disease, and the current diagnosis is a frequent go to the hospital for testing. Objective: In order to improve the convenience and speed of detection, in this paper, we have developed a hand-held zoom micro-imaging system based on a microfluidic chip for point-of-care testing (POCT) of vaginal inflammation. Methods: This system consists of a microfluidic chip, an optical system and a hand-held zoom system assembled with a mobile phone. In terms of hardware, we designed a self-priming microfluidic chip, which can realize automatic sampling and full mixing of samples. We have also developed an optical system that can be adapted to smartphones, which has a lens group with a 37x magnification function and equipped with a zoom system with a focus range of 4mm to 6mm. In terms of software, we proposed an APP that can accurately identify cocci and can determine the inflammation level. Results: Compared with the recognition rate of the observers in the hospital, the detection accuracy of the portable recognition system is 95%, and after testing the clinical samples, the results were completely consistent with the hospital diagnosis results. The detection limit was 500 CFU / ml, which the relative error was (0.9 ± 0.3) %, and recognition time is 7 seconds. Conclusion: This system is definitely suitable for women’s point-of-care testing (POCT). IEEE 2021-01-26 /pmc/articles/PMC7861347/ /pubmed/33552751 http://dx.doi.org/10.1109/JTEHM.2021.3054556 Text en https://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation |
title | Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation |
title_full | Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation |
title_fullStr | Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation |
title_full_unstemmed | Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation |
title_short | Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation |
title_sort | hand-held zoom micro-imaging system based on microfluidic chip for point-of-care testing (poct) of vaginal inflammation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7861347/ https://www.ncbi.nlm.nih.gov/pubmed/33552751 http://dx.doi.org/10.1109/JTEHM.2021.3054556 |
work_keys_str_mv | AT handheldzoommicroimagingsystembasedonmicrofluidicchipforpointofcaretestingpoctofvaginalinflammation AT handheldzoommicroimagingsystembasedonmicrofluidicchipforpointofcaretestingpoctofvaginalinflammation AT handheldzoommicroimagingsystembasedonmicrofluidicchipforpointofcaretestingpoctofvaginalinflammation AT handheldzoommicroimagingsystembasedonmicrofluidicchipforpointofcaretestingpoctofvaginalinflammation AT handheldzoommicroimagingsystembasedonmicrofluidicchipforpointofcaretestingpoctofvaginalinflammation AT handheldzoommicroimagingsystembasedonmicrofluidicchipforpointofcaretestingpoctofvaginalinflammation |