Cargando…
Development of a method for measuring spleen stiffness by transient elastography using a new device and ultrasound-fusion method
BACKGROUND: Hepatic venous pressure gradient (HVPG) is the gold standard index for evaluating portal hypertension; however, measuring HVPG is invasive. Although transient elastography (TE) is the most common procedure for evaluating organ stiffness, accurate measurement of spleen stiffness (SS) is d...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7861355/ https://www.ncbi.nlm.nih.gov/pubmed/33539456 http://dx.doi.org/10.1371/journal.pone.0246315 |
Sumario: | BACKGROUND: Hepatic venous pressure gradient (HVPG) is the gold standard index for evaluating portal hypertension; however, measuring HVPG is invasive. Although transient elastography (TE) is the most common procedure for evaluating organ stiffness, accurate measurement of spleen stiffness (SS) is difficult. We developed a device to demonstrate the diagnostic precision of TE and suggest this technique as a valuable new method to measure SS. METHODS: Of 292 consecutive patients enrolled in this single-centre, translational, cross-sectional study from June through September in 2019, 200 underwent SS measurement (SSM) using an M probe (training set, n = 130; inspection set, n = 70). We performed TE with B-mode imaging using an ultrasound-fusion method, printed new devices with a three-dimensional printer, and attached the magnetic position sensor to the convex and M probes. We evaluated the diagnostic precision of TE to evaluate the risk of esophagogastric varices (EGVs). RESULTS: The median spleen volume was 245 mL (range, 64–1,720 mL), and it took 2 minutes to acquire a B-mode image using the ultrasound-fusion method. The median success rates of TE were 83.3% and 57.6% in patients with and without the new device, respectively (p<0.001); it was 76.9% and 35.0% in patients with and without splenomegaly (<100 mL), respectively (p<0.001). In the prediction of EGVs, the areas under the receiver operating characteristic curve were 0.921 and 0.858 in patients with and without the new device, respectively (p = 0.043). When the new device was attached, the positive and negative likelihood ratios were 3.44 and 0.11, respectively. The cut-off value of SSM was 46.0 kPa. Data that were similar between the validation and training sets were obtained. CONCLUSIONS: The SS can be precisely measured using this new device with TE and ultrasound-fusion method. Similarly, we can estimate the bleeding risk due to EGV using this method. |
---|