Cargando…

Aerosol generation and control in the dental operatory: An in vitro spectrometric study of typical clinical setups

Dental turbines and scalers, used every day in dental operatories, feature built-in water spray that generates considerable amounts of water aerosol. The problem is that it is not exactly known how much. Since the outbreak of COVID-19, several aerosol safety recommendations have been issued—based on...

Descripción completa

Detalles Bibliográficos
Autores principales: Kun-Szabó, Fruzsina, Gheorghita, Dorottya, Ajtai, Tibor, Hodovány, Szabolcs, Bozóki, Zoltán, Braunitzer, Gábor, Antal, Márk Ádám
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7861533/
https://www.ncbi.nlm.nih.gov/pubmed/33539439
http://dx.doi.org/10.1371/journal.pone.0246543
Descripción
Sumario:Dental turbines and scalers, used every day in dental operatories, feature built-in water spray that generates considerable amounts of water aerosol. The problem is that it is not exactly known how much. Since the outbreak of COVID-19, several aerosol safety recommendations have been issued—based on little empirical evidence, as almost no data are available on the exact aerosol concentrations generated during dental treatment. Similarly, little is known about the differences in the efficacy of different commercially available aerosol control systems to reduce in-treatment aerosol load. In this in vitro study, we used spectrometry to explore these questions. The time-dependent effect of conventional airing on aerosol concentrations was also studied. Everyday patient treatment situations were modeled. The test setups were defined by the applied instrument and its spray direction (high-speed turbine with direct/indirect airspray or ultrasonic scaler with indirect airspray) and the applied aerosol control system (the conventional high-volume evacuator or a lately introduced aerosol exhaustor). Two parameters were analyzed: total number concentration in the entire measurement range of the spectrometer and total number concentration within the 60 to 384 nm range. The results suggest that instrument type and spray direction significantly influence the resulting aerosol concentrations. Aerosol generation by the ultrasonic scaler is easily controlled. As for the high-speed turbine, the efficiency of control might depend on how exactly the instrument is used during a treatment. The results suggest that scenarios where the airspray is frequently directed toward the air of the operatory are the most difficult to control. The tested control systems did not differ in their efficiency, but the study could not provide conclusive results in this respect. With conventional airing through windows with a standard fan, a safety airing period of at least 15 minutes between treatments is recommended.