Instant rule-out of suspected non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin T with Copeptin versus a single low high-sensitivity cardiac troponin T: findings from a large pooled individual data analysis on 10,329 patients
BACKGROUND: Evidence is sparse and inconsistent on the role of a dual marker strategy (DMS) combining Copeptin with cardiac troponin T (cTnT) for instant rule-out of a non-ST-segment myocardial infarction (NSTEMI) when high sensitivity cardiac troponin T (hs-cTnT) is used. METHODS: Data on 10,329 pa...
Autores principales: | Giannitsis, Evangelos, Huber, K., Hamm, C. W., Möckel, M. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7862196/ https://www.ncbi.nlm.nih.gov/pubmed/32671467 http://dx.doi.org/10.1007/s00392-020-01712-y |
Ejemplares similares
-
High-sensitivity troponin I with or without ultra-sensitive copeptin for the instant rule-out of acute myocardial infarction
por: Ricci, Fabrizio, et al.
Publicado: (2022) -
Cost analysis of early discharge using combined copeptin/cardiac troponin testing versus serial cardiac troponin testing in patients with suspected acute coronary syndrome
por: Reinhold, Thomas, et al.
Publicado: (2018) -
Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
por: Kim, Kyung Su, et al.
Publicado: (2020) -
Prognostic Value of Elevated Copeptin and High-Sensitivity Cardiac Troponin T in Patients with and without Acute Coronary Syndrome: The ConTrACS Study
por: Waldsperger, Hanna, et al.
Publicado: (2020) -
Point-of-care testing with high-sensitivity cardiac troponin assays: the challenges and opportunities
por: Cullen, Louise, et al.
Publicado: (2022)