Cargando…

Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides

Purpose: The aim of this in vitro study is to evaluate the accuracy of implant position using mucosal supported surgical guides, produced by a desktop 3D printer. Methods: Ninety implants (Bone Level Roxolid, 4.1 mm × 10 mm, Straumann, Villerat, Switzerland) were placed in fifteen mandibular casts (...

Descripción completa

Detalles Bibliográficos
Autores principales: D’haese, Rani, Vrombaut, Tom, Hommez, Geert, De Bruyn, Hugo, Vandeweghe, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7864156/
https://www.ncbi.nlm.nih.gov/pubmed/33498516
http://dx.doi.org/10.3390/jcm10030391
_version_ 1783647611285143552
author D’haese, Rani
Vrombaut, Tom
Hommez, Geert
De Bruyn, Hugo
Vandeweghe, Stefan
author_facet D’haese, Rani
Vrombaut, Tom
Hommez, Geert
De Bruyn, Hugo
Vandeweghe, Stefan
author_sort D’haese, Rani
collection PubMed
description Purpose: The aim of this in vitro study is to evaluate the accuracy of implant position using mucosal supported surgical guides, produced by a desktop 3D printer. Methods: Ninety implants (Bone Level Roxolid, 4.1 mm × 10 mm, Straumann, Villerat, Switzerland) were placed in fifteen mandibular casts (Bonemodels, Castellón de la Plana, Spain). A mucosa-supported guide was designed and printed for each of the fifteen casts. After placement of the implants, the location was assessed by scanning the cast and scan bodies with an intra-oral scanner (Primescan(®), Dentsply Sirona, York, PA, USA). Two comparisons were performed: one with the mucosa as a reference, and one where only the implants were aligned. Angular, coronal and apical deviations were measured. Results: The mean implant angular deviation for tissue and implant alignment were 3.25° (SD 1.69°) and 2.39° (SD 1.42°) respectively, the coronal deviation 0.82 mm (SD 0.43 mm) and 0.45 mm (SD 0.31 mm) and the apical deviation 0.99 mm (SD 0.45 mm) and 0.71 mm (SD 0.43 mm). All three variables were significantly different between the tissue and implant alignment (p < 0.001). Conclusion: Based on the results of this study, we conclude that guided implant surgery using desktop 3D printed mucosa-supported guides has a clinically acceptable level of accuracy. The resilience of the mucosa has a negative effect on the guide stability and increases the deviation in implant position.
format Online
Article
Text
id pubmed-7864156
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78641562021-02-06 Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides D’haese, Rani Vrombaut, Tom Hommez, Geert De Bruyn, Hugo Vandeweghe, Stefan J Clin Med Article Purpose: The aim of this in vitro study is to evaluate the accuracy of implant position using mucosal supported surgical guides, produced by a desktop 3D printer. Methods: Ninety implants (Bone Level Roxolid, 4.1 mm × 10 mm, Straumann, Villerat, Switzerland) were placed in fifteen mandibular casts (Bonemodels, Castellón de la Plana, Spain). A mucosa-supported guide was designed and printed for each of the fifteen casts. After placement of the implants, the location was assessed by scanning the cast and scan bodies with an intra-oral scanner (Primescan(®), Dentsply Sirona, York, PA, USA). Two comparisons were performed: one with the mucosa as a reference, and one where only the implants were aligned. Angular, coronal and apical deviations were measured. Results: The mean implant angular deviation for tissue and implant alignment were 3.25° (SD 1.69°) and 2.39° (SD 1.42°) respectively, the coronal deviation 0.82 mm (SD 0.43 mm) and 0.45 mm (SD 0.31 mm) and the apical deviation 0.99 mm (SD 0.45 mm) and 0.71 mm (SD 0.43 mm). All three variables were significantly different between the tissue and implant alignment (p < 0.001). Conclusion: Based on the results of this study, we conclude that guided implant surgery using desktop 3D printed mucosa-supported guides has a clinically acceptable level of accuracy. The resilience of the mucosa has a negative effect on the guide stability and increases the deviation in implant position. MDPI 2021-01-20 /pmc/articles/PMC7864156/ /pubmed/33498516 http://dx.doi.org/10.3390/jcm10030391 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
D’haese, Rani
Vrombaut, Tom
Hommez, Geert
De Bruyn, Hugo
Vandeweghe, Stefan
Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides
title Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides
title_full Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides
title_fullStr Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides
title_full_unstemmed Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides
title_short Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides
title_sort accuracy of guided implant surgery in the edentulous jaw using desktop 3d-printed mucosal supported guides
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7864156/
https://www.ncbi.nlm.nih.gov/pubmed/33498516
http://dx.doi.org/10.3390/jcm10030391
work_keys_str_mv AT dhaeserani accuracyofguidedimplantsurgeryintheedentulousjawusingdesktop3dprintedmucosalsupportedguides
AT vrombauttom accuracyofguidedimplantsurgeryintheedentulousjawusingdesktop3dprintedmucosalsupportedguides
AT hommezgeert accuracyofguidedimplantsurgeryintheedentulousjawusingdesktop3dprintedmucosalsupportedguides
AT debruynhugo accuracyofguidedimplantsurgeryintheedentulousjawusingdesktop3dprintedmucosalsupportedguides
AT vandeweghestefan accuracyofguidedimplantsurgeryintheedentulousjawusingdesktop3dprintedmucosalsupportedguides