Cargando…

Oxygen administration for patients with ARDS

Acute respiratory distress syndrome (ARDS) is a fatal condition with insufficiently clarified etiology. Supportive care for severe hypoxemia remains the mainstay of essential interventions for ARDS. In recent years, adequate ventilation to prevent ventilator-induced lung injury (VILI) and patient se...

Descripción completa

Detalles Bibliográficos
Autor principal: Ohshimo, Shinichiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7865109/
https://www.ncbi.nlm.nih.gov/pubmed/33549131
http://dx.doi.org/10.1186/s40560-021-00532-0
_version_ 1783647778901065728
author Ohshimo, Shinichiro
author_facet Ohshimo, Shinichiro
author_sort Ohshimo, Shinichiro
collection PubMed
description Acute respiratory distress syndrome (ARDS) is a fatal condition with insufficiently clarified etiology. Supportive care for severe hypoxemia remains the mainstay of essential interventions for ARDS. In recent years, adequate ventilation to prevent ventilator-induced lung injury (VILI) and patient self-inflicted lung injury (P-SILI) as well as lung-protective mechanical ventilation has an increasing attention in ARDS. Ventilation-perfusion mismatch may augment severe hypoxemia and inspiratory drive and consequently induce P-SILI. Respiratory drive and effort must also be carefully monitored to prevent P-SILI. Airway occlusion pressure (P(0.1)) and airway pressure deflection during an end-expiratory airway occlusion (P(occ)) could be easy indicators to evaluate the respiratory drive and effort. Patient-ventilator dyssynchrony is a time mismatching between patient’s effort and ventilator drive. Although it is frequently unrecognized, dyssynchrony can be associated with poor clinical outcomes. Dyssynchrony includes trigger asynchrony, cycling asynchrony, and flow delivery mismatch. Ventilator-induced diaphragm dysfunction (VIDD) is a form of iatrogenic injury from inadequate use of mechanical ventilation. Excessive spontaneous breathing can lead to P-SILI, while excessive rest can lead to VIDD. Optimal balance between these two manifestations is probably associated with the etiology and severity of the underlying pulmonary disease. High-flow nasal cannula (HFNC) and non-invasive positive pressure ventilation (NPPV) are non-invasive techniques for supporting hypoxemia. While they are beneficial as respiratory supports in mild ARDS, there can be a risk of delaying needed intubation. Mechanical ventilation and ECMO are applied for more severe ARDS. However, as with HFNC/NPPV, inappropriate assessment of breathing workload potentially has a risk of delaying the timing of shifting from ventilator to ECMO. Various methods of oxygen administration in ARDS are important. However, it is also important to evaluate whether they adequately reduce the breathing workload and help to improve ARDS.
format Online
Article
Text
id pubmed-7865109
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-78651092021-02-09 Oxygen administration for patients with ARDS Ohshimo, Shinichiro J Intensive Care Review Acute respiratory distress syndrome (ARDS) is a fatal condition with insufficiently clarified etiology. Supportive care for severe hypoxemia remains the mainstay of essential interventions for ARDS. In recent years, adequate ventilation to prevent ventilator-induced lung injury (VILI) and patient self-inflicted lung injury (P-SILI) as well as lung-protective mechanical ventilation has an increasing attention in ARDS. Ventilation-perfusion mismatch may augment severe hypoxemia and inspiratory drive and consequently induce P-SILI. Respiratory drive and effort must also be carefully monitored to prevent P-SILI. Airway occlusion pressure (P(0.1)) and airway pressure deflection during an end-expiratory airway occlusion (P(occ)) could be easy indicators to evaluate the respiratory drive and effort. Patient-ventilator dyssynchrony is a time mismatching between patient’s effort and ventilator drive. Although it is frequently unrecognized, dyssynchrony can be associated with poor clinical outcomes. Dyssynchrony includes trigger asynchrony, cycling asynchrony, and flow delivery mismatch. Ventilator-induced diaphragm dysfunction (VIDD) is a form of iatrogenic injury from inadequate use of mechanical ventilation. Excessive spontaneous breathing can lead to P-SILI, while excessive rest can lead to VIDD. Optimal balance between these two manifestations is probably associated with the etiology and severity of the underlying pulmonary disease. High-flow nasal cannula (HFNC) and non-invasive positive pressure ventilation (NPPV) are non-invasive techniques for supporting hypoxemia. While they are beneficial as respiratory supports in mild ARDS, there can be a risk of delaying needed intubation. Mechanical ventilation and ECMO are applied for more severe ARDS. However, as with HFNC/NPPV, inappropriate assessment of breathing workload potentially has a risk of delaying the timing of shifting from ventilator to ECMO. Various methods of oxygen administration in ARDS are important. However, it is also important to evaluate whether they adequately reduce the breathing workload and help to improve ARDS. BioMed Central 2021-02-06 /pmc/articles/PMC7865109/ /pubmed/33549131 http://dx.doi.org/10.1186/s40560-021-00532-0 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Ohshimo, Shinichiro
Oxygen administration for patients with ARDS
title Oxygen administration for patients with ARDS
title_full Oxygen administration for patients with ARDS
title_fullStr Oxygen administration for patients with ARDS
title_full_unstemmed Oxygen administration for patients with ARDS
title_short Oxygen administration for patients with ARDS
title_sort oxygen administration for patients with ards
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7865109/
https://www.ncbi.nlm.nih.gov/pubmed/33549131
http://dx.doi.org/10.1186/s40560-021-00532-0
work_keys_str_mv AT ohshimoshinichiro oxygenadministrationforpatientswithards